Kang Liu

Mr. Kang Liu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2023 in IEEE Access
Verified
Journal Article
Open access
KLKang Liu
Kang Liu
YFYudi Fan
Yudi Fan
JMJianqiao Ma
Jianqiao Ma
YWYihu Wang
Yihu Wang
HXHao Xu
Hao Xu
The increase in bird populations along the Hexi Corridor has led to an increase in flashover faults on 330 kV transmission lines caused by bird droppings. To mitigate the issue of line tripping caused by bird droppings, it is necessary to analyze the distribution of the electric field near composite insulators during the process of bird droppings falling. A three-dimensional model, including the tower, bird droppings, and insulators, was created to assess the impact of bird droppings’ characteristics on the electric field near the insulators. Based on simulation results, a bird-proof cover was designed to modify the trajectory of the bird droppings’ path. The research found that when bird droppings are grounded and continuous, the most severe distortion of the residual air gap field occurs at a distance of 599.34 mm from the insulator axis. In the dynamic process of ungrounded and continuous bird droppings falling downward with a length less than 3200 mm, the electric field intensity in the residual air gap remains below 5.66 kV/cm outside the circular area centered at the insulator skirt with a radius of 740 mm. Based on the simulation results under both single-end grounded and ungrounded conditions of bird droppings, a bird-proof cover structure was devised to alter the location where bird droppings fall. After bird droppings fall along the edges of the bird-proof cover, the average electric field intensity between the bird droppings and the high-voltage terminal is maintained below 3.02 kV/cm. These research findings lay the foundation for subsequent fabrication of physical models of bird-proof covers.

12 July 2024 in IEEE Access
Verified
Journal Article
Open access
WWWenzhuo Wang
Wenzhuo Wang
ZMZhenxiang Ma
Zhenxiang Ma
YFYudi Fan
Yudi Fan
JMJianqiao Ma
Jianqiao Ma
KLKang Liu
Kang Liu
HXHao Xu
Hao Xu
Recently, the number of birds along the 330kV transmission lines in the northwest region has gradually increased. The frequency of birds nesting and excreting on the towers has been steadily rising, with bird droppings increasingly becoming the primary factor causing bird-related tripping faults. A three-dimensional model of the tower cross arm, continuous bird droppings, and insulators was constructed to simulate and analyze the impact characteristics of bird droplet diameter, length, and relative position to insulators on the spatial electric field near the insulators. Experimental corrections were made, and based on simulation and experimental results, a bird-proof baffle was designed. Research results indicate that under conditions of single-ended grounding and suspended droplets of bird droppings, the average electric field strength at the lower end of the bird droppings and the grading ring was extracted to define the protective area against irregular-shaped bird droppings. After experimental validation, a correction coefficient of 1.4 was obtained based on the experimental results. A square protective baffle with a diversion function was designed based on simulation and experimental results. Bird droppings were placed at the baffle’s diversion groove, and the average electric field strength between the lower end of the bird droppings and the grading ring was consistently lower than the breakdown field strength of 2.98 kV/cm. The research results of this paper can serve as a basis for the subsequent designing of physical models of bird-proof baffles and prevention of bird-related flashover faults on V-type insulators.

16 October 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KLKang Liu
Kang Liu
YFYudi Fan
Yudi Fan
ZMZhenxiang Ma
Zhenxiang Ma
JMJianqiao Ma
Jianqiao Ma
MTMingxing Tian
Mingxing Tian
SZShuyao Zhang
Shuyao Zhang
When the radius of protection against bird droppings is determined for 330 kV insulators in line with the standard GB/T 35695-2017, the influence of the shielding ring is ignored. Also, bird droppings can’t be prevented from flashing accidents by the protection range with a radius of 0.85 m from the center of the insulator axis. Therefore, it is proposed in this paper to determine the bird droppings protection range (BDPR) by introducing a rotational scanning method along the shielding ring boundary. It is discovered that the average breakdown electric field strength (BEFS) of the residual air gap (RAG) is 3.38 kV/cm when the cotton cord rope end is above the cylindrical tube of the shielding ring, 3.0 kV/cm when the rope end is positioned on the outside of the cylindrical tube, and 2.7 kV/cm when the rope end is located on the outer-side of the curved tube of the shielding ring. The other three shielding rings are used to verify the universality of the proposed method in determining the range of protection against bird droppings flashover.


1 July 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
KLKang Liu
Kang Liu
DWDingjun Wen
Dingjun Wen
GZGuangdong Zhang
Guangdong Zhang
CHChunjiang Hu
Chunjiang Hu
YCYing Chen
Ying Chen
There is a difference between the actual impedance of substations' ground grid under harmonic interference and that measured under power frequency. Especially under strong harmonic interference, the difference becomes more obvious between the actual one and that measured under power frequency. A method is proposed in this paper to calculate parameters of ground grid models by measuring the ground grid impedances under power frequency and then calculate those under harmonic interference. This method is capable of solving the problem that it is impossible to measure the actual grounding impedance of substations operating under harmonic waves. The feasibility of the method is verified by means of simulating calculations. After correcting by this method, the grounding impedance modulus error becomes less than 2% and the impedance angle error less than 10%. This method may be applied to the measurement and analysis of grounding impedances of substations under harmonic interference.

17 November 2026 in Energies
Verified
Journal Article
Open access
PDF file
JZJia Zhang
Jia Zhang
BCBodong Chen
Bodong Chen
KLKang Liu
Kang Liu
TWTiancun Wu
Tiancun Wu
HWHailong Wang
Hailong Wang
MWMiao Wen
Miao Wen
To clarify the electrothermal failure of fixed contacts in a 363 kV three-phase five-column disconnector, field inspection, circuit-resistance tests, contact-mechanical modeling, finger-level resistance calculation, and electrothermal simulation were combined. The fault side had approximately 10 mm settlement and 51 mm horizontal displacement. Unserved contacts remained at 81–83 μΩ, whereas field-served contacts showed displacement-sensitive, non-monotonic resistance changes. A finite element model of 24 contact fingers with assembly-induced prestress was developed. Contact pressures were calculated under normal, settlement, and combined settlement—horizontal displacement conditions. Normal force was integrated over each contact area, and zero pressure denoted contact loss. The force, contact length, and equivalent contact width were used in a cylinder-on-flat model to calculate finger resistance. These resistances were connected in parallel and calibrated against the measured normal-state resistance of 83.57 μΩ. Settlement redistributed load from lower to upper fingers, while further horizontal displacement concentrated contact on one side; eastward displacement caused all bottom-row fingers to lose contact. Electrothermal simulation showed little temperature change while most fingers remained in contact, but temperatures exceeded 130 °C after bottom-row contact loss. Thus, total resistance can conceal local degradation, while load redistribution and current concentration increase Joule heating in remaining paths and explain burnout.