A phase spread frequency sampling method is proposed. This method can be used to correct the nonlinearity in the beat frequency of a measurement signal. The proposed method expands the phase of the auxiliary interference beat signal, thereby satisfying the Nyquist sampling theorem, correcting the nonlinearity in the beat frequency of the measured signal, and solving the problem of limited range. The conditions over which the frequency sampling method can be applied are expanded. The measurement range is flexibly expanded by performing multiple phase expansions.
The laser swept-frequency interferometric ranging method is commonly used in the field of large-scale, high-precision, and non-cooperative measurements. However, this method requires the laser chirp curve to be a stable straight line. Nonlinearities in the chirp can cause broadening of the target spectrum, which affects the accuracy of the frequency extraction of the beat signal, resulting in increased ranging error. Herein, a linear regression laser swept-frequency interferometry method based on the non-uniform fast Fourier transform is proposed, which effectively suppresses the influence of frequency modulation nonlinearity on ranging accuracy.
A temperature compensation method is proposed to solve the ranging precision decrease problem of the frequency-modulated continuous wave distance measurement system. The set of phases spread frequency sampling method is used to correct the beat frequency signal non-linearity. The influence model of temperature on the optical fiber auxiliary interferometer is studied. The experimental results show that distance measurement error decreases from 0.3432 mm to 0.02260 mm, and the mean measurement standard deviation decreases from 0.1088 mm to 0.01733 mm on a maximum measurement range of 1.6 m after compensation.
A combined tip-sample scanning architecture can improve the imaging speed of atomic force microscopy (AFM). However, the nonorthogonality between the three scanners and the nonideal response of each scanner cause measurement errors. In this article, the authors systematically analyze the influence of the installation and response errors of the combined scanning architecture. The experimental results show that when the probe in the homemade high-speed AFM moves with the Z-scanner, the spot position on the four-quadrant detector changes, thus introducing measurement error. Comparing the experimental results with the numerical and theoretical results shows that the undesired motion of the Z-scanner introduces a large error. The authors believe that this significant error occurs because the piezoelectric actuator not only stretches along the polarization direction but also swings under nonuniform multifield coupling. This article proposes a direction for further optimizing the instrument and provides design ideas for similar high-speed atomic force microscopes.