Xinke Xu

Dr. Xinke Xu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
XZXuebingqing Zhang
Xuebingqing Zhang
MKMing Kong
Ming Kong
TGTiantai Guo
Tiantai Guo
JZJun Zhao
Jun Zhao
DWDaodang Wang
Daodang Wang
XXXinke Xu
Xinke Xu
A phase spread frequency sampling method is proposed. This method can be used to correct the nonlinearity in the beat frequency of a measurement signal. The proposed method expands the phase of the auxiliary interference beat signal, thereby satisfying the Nyquist sampling theorem, correcting the nonlinearity in the beat frequency of the measured signal, and solving the problem of limited range. The conditions over which the frequency sampling method can be applied are expanded. The measurement range is flexibly expanded by performing multiple phase expansions.

7 September 2023 in Applied Optics
Verified
Journal Article
Closed access
YLYi Liu
Yi Liu
XXXinke Xu
Xinke Xu
ZHZecong He
Zecong He
CJChenkai Jin
Chenkai Jin
SHShengpan Hu
Shengpan Hu
YLY L
Y L
The laser swept-frequency interferometric ranging method is commonly used in the field of large-scale, high-precision, and non-cooperative measurements. However, this method requires the laser chirp curve to be a stable straight line. Nonlinearities in the chirp can cause broadening of the target spectrum, which affects the accuracy of the frequency extraction of the beat signal, resulting in increased ranging error. Herein, a linear regression laser swept-frequency interferometry method based on the non-uniform fast Fourier transform is proposed, which effectively suppresses the influence of frequency modulation nonlinearity on ranging accuracy.

14 June 2023 in Applied Optics
Verified
Journal Article
Closed access
SHShengpan Hu
Shengpan Hu
XXXinke Xu
Xinke Xu
HWHe Wen
He Wen
A temperature compensation method is proposed to solve the ranging precision decrease problem of the frequency-modulated continuous wave distance measurement system. The set of phases spread frequency sampling method is used to correct the beat frequency signal non-linearity. The influence model of temperature on the optical fiber auxiliary interferometer is studied. The experimental results show that distance measurement error decreases from 0.3432 mm to 0.02260 mm, and the mean measurement standard deviation decreases from 0.1088 mm to 0.01733 mm on a maximum measurement range of 1.6 m after compensation.

13 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LLLiu Lu
Liu Lu
MKMing Kong
Ming Kong
SWSen Wu
Sen Wu
XXXinke Xu
Xinke Xu
DWDaodang Wang
Daodang Wang
A combined tip-sample scanning architecture can improve the imaging speed of atomic force microscopy (AFM). However, the nonorthogonality between the three scanners and the nonideal response of each scanner cause measurement errors. In this article, the authors systematically analyze the influence of the installation and response errors of the combined scanning architecture. The experimental results show that when the probe in the homemade high-speed AFM moves with the Z-scanner, the spot position on the four-quadrant detector changes, thus introducing measurement error. Comparing the experimental results with the numerical and theoretical results shows that the undesired motion of the Z-scanner introduces a large error. The authors believe that this significant error occurs because the piezoelectric actuator not only stretches along the polarization direction but also swings under nonuniform multifield coupling. This article proposes a direction for further optimizing the instrument and provides design ideas for similar high-speed atomic force microscopes.

1 January 2023 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
KLKang Long
Kang Long
MKMing Kong
Ming Kong
LLLu Liu
Lu Liu
WLWei Liu
Wei Liu
HHHang-Bo Hua
Hang-Bo Hua
XXXinke Xu
Xinke Xu
激光扫频干涉测量技术因其精度高、抗干扰能力强等优势成为研究热点。而激光器调频的非线性问题一直是影响测量精度的关键因素,非线性带来的直观结果就是拍信号的频谱严重展宽,造成测距精度下降。为解决该问题,本文提出了一种基于Lomb-Scargle算法的非线性校正方法,搭建了具有辅助干涉仪的激光扫频干涉测量系统,通过对辅助路拍信号进行希尔伯特变换提取相位,再基于提取到的相位信息生成一个新的时间序列,结合Lomb-Scargle算法,将非线性校正与拍信号频率计算同时进行。作为验证,对于0.5m至1.3m范围内的目标进行了测量,最大误差为14μm。区别于传统频率采样法校正原理,本文提出的校正方法并不是以辅助路的拍信号对测量路进行重采样,所以无需满足辅助干涉仪光程差大于测量路光程差两倍的条件,因而可为增大测距量程提供一种思路。