A voltage balancer (VB) can be used to balance voltages under load unbalance in either a bipolar DC microgrid or LVDC (Low voltage DC) distribution system. An interleaved buck-type VB has advantages over other voltage balance topologies for reduction in output current ripple by an aspect of configuration of a physically symmetrical structure. Similarly, magnetic coupling such as winding two or more magnetic components into a single magnetic component can be selected to enhance the power density and dynamic response. In order to achieve these advantages in a VB, this paper proposes a VB with a coupled inductor (CI) as a substitute for inductors in a two-stage interleaved buck-type VB circuit. Based on patterns of switch poles under load variation, the variation in inductor currents under four switching patterns is induced. The proposed CI is derived from self-inductance based on the configuration structure that has a two-stage interleaved buck type and mathematical design results based on the coupling coefficient, where the coupling coefficient is a key factor in the determination of the dynamic response of the proposed VB in load variation. According to the results, a prototype scale is implemented to confirm the feasibility and effectiveness of the proposed VB.
The droop control strategy is widely used in islanded microgrids to control power flows according to the load condition, with the absence of a critical communication line, interfacing distributed energy sources to provide for the active and reactive power demand of loads. In this case, the system modeling for both steady-state and transient time is one of the key issues of a droop-controlled system for an inverter-based microgrid (MG). With the rapid development of microgrids, it is essential to identify the system stability and optimize the control parameters, taking into account the network and control dynamics caused by multiple tasks such as electric signal filtering, network synchronization, and so on. Therefore, in order to improve model accuracy and determine control coefficients, this paper analyzes and extends a dynamic phasor-based model to the droop-controlled parallel-inverters, considering network and control dynamics such as a low-pass filter, a second-order generalized integrator frequency-locked-loop (SOGI-FLL), and a system operating sequence. Moreover, discussed in this paper are both the design approaches for and the implementation of a droop-controlled parallel-inverter, which enables the system to be stable and reliable. To demonstrate the effectiveness and validity of this paper, PSIM simulation was performed and two parallel-inverters were combined as the proposed design procedure for the 4-kVA prototypes.
Input-Series-Output-Parallel (ISOP) converters, a kind of modular converter, are used in high-input voltage and high-output current applications. In ISOP converters, Input Voltage Sharing (IVS) and Output Current Sharing (OCS) should be implemented for stable operation. In order to solve this problem, this paper proposes a decentralized control method. In the proposed control, output current reference is changed according to the decentralized control characteristic in individual current control loops. In this way, the proposed control method is able to implement IVS and OCS without communication. Also, this method can be easily used in current control loops and has high reliability compared to conventional control methods that require communication. In this paper, the operation principle is described to elucidate the proposed control and a small signal model of an ISOP converter is also implemented. Based on the small signal model, IVS stability analysis is performed using pole-zero maps with varying coefficients and control gains. In addition, the current control loop is designed in a stable region. In order to demonstrate the proposed control method, a prototype ISOP converter is configured using full-bridge converters. The performance of IVS and OCS in an ISOP converter is verified by experimental result.
Ensuring a protection scheme in a DC distribution system is more difficult to achieve against pole-to-ground faults than in AC distribution system because of the absence of zero crossing points and low line impedance. To complement the major obstacle of limiting the fault current, several compositions have been proposed related to mechanical switching and solid-state switching. Among them, solid-state circuit breakers (SSCBs) are considered to be a possible solution to limit fast fault current. However, they may cause problems in circuit complexity, reliability, and cost-related troubles because of the use of multiple power semiconductor devices and additional circuit configuration to commutate the current. This paper proposes a SSCB with a coupled inductor (SSCB-CI) that has a symmetrical configuration. The circuit is comprised of passive components like commutation capacitors, a CI, and damping resistors. Thus, the proposed SSCB-CI offers the advantages of a simple circuit configuration and fewer utilized power semiconductor devices than the other typical SSCBs in the DC microgrid. For the analysis, six operation states are described for the voltage across the main switches and fault current. The effectiveness of the SSCB-CI against the short-circuit fault is proved via simulation and experimental results in a lab-scale prototype.