Hyung-Jun Byun

Mr. Hyung-Jun Byun

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SKSung-Hun Kim
Sung-Hun Kim
HBHyung-Jun Byun
Hyung-Jun Byun
WJWon-Sang Jeong
Won-Sang Jeong
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
Bipolar dc microgrid (MG) based on two voltage levels with three wires has higher reliability and flexibility than unipolar dc MG. However, the voltages of bipolar buses are coupled and the voltage of the PN bus affects the voltages of the bipolar buses in bipolar dc MG. In this article, a hierarchical control with voltage balancing and energy management based on the characteristics of bipolar dc MG is proposed. To perform distributed power sharing with coupled voltages, droop-based primary controls for three buses and the coupling relationships between three buses are analyzed. Furthermore, in secondary control, balancing and voltage restoration controls are proposed to compensate for voltage drops caused by the balanced and unbalanced loads. To design the proposed hierarchical control, the stability analysis is performed. Additionally, a tertiary control based on an artificial neural network is proposed for state-of-charge management of bipolar dc MG. Experimental results of the proposed hierarchical control are verified by a lab-scale bipolar dc MG and performance analysis is performed with experimental and ideal results.

22 November 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HBHyung-Jun Byun
Hyung-Jun Byun
SKSung-Hun Kim
Sung-Hun Kim
YLYoon-Seong Lee
Yoon-Seong Lee
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
The main assignment of a bipolar dc microgrid is the settlement of the bipolar voltage imbalance due to unbalanced loads and asymmetric powers. It is necessary to consider maintaining the bipolar systems whether in grid-connected mode or islanded mode of the microgrid. This article introduces the control strategy of the triple-active-bridge (TAB) converter for the bipolar dc microgrid by voltage balancing. The presented control strategy performs PN voltage regulation and voltage balancing based on the interrelation analysis between power and voltage in the bipolar dc microgrid. With the separately configured voltage balancing loop in the controller, the active voltage balancing through the power transfer between the bipolar buses is ensured even in the islanded mode without additional circuit components. The TAB converter operates with phase-shift modulation as conventional, and the control strategy is implemented through the digital signal processor. The validity of the proposal is verified by lab-scale experimental results.

1 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
JPJung-Min Park
Jung-Min Park
HBHyung-Jun Byun
Hyung-Jun Byun
BKBum-Jun Kim
Bum-Jun Kim
SKSung-Hun Kim
Sung-Hun Kim
CWChung-Yuen Won
Chung-Yuen Won
A voltage balancer (VB) can be used to balance voltages under load unbalance in either a bipolar DC microgrid or LVDC (Low voltage DC) distribution system. An interleaved buck-type VB has advantages over other voltage balance topologies for reduction in output current ripple by an aspect of configuration of a physically symmetrical structure. Similarly, magnetic coupling such as winding two or more magnetic components into a single magnetic component can be selected to enhance the power density and dynamic response. In order to achieve these advantages in a VB, this paper proposes a VB with a coupled inductor (CI) as a substitute for inductors in a two-stage interleaved buck-type VB circuit. Based on patterns of switch poles under load variation, the variation in inductor currents under four switching patterns is induced. The proposed CI is derived from self-inductance based on the configuration structure that has a two-stage interleaved buck type and mathematical design results based on the coupling coefficient, where the coupling coefficient is a key factor in the determination of the dynamic response of the proposed VB in load variation. According to the results, a prototype scale is implemented to confirm the feasibility and effectiveness of the proposed VB.

11 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
SKSung-Hun Kim
Sung-Hun Kim
HBHyung-Jun Byun
Hyung-Jun Byun
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
Bipolar DC microgrids (BDCMGs) have several issues related to the voltage and require numerous converters to supply power to both poles. To solve these issues, a bidirectional dual-input dual-output (DIDO) converter is proposed for the voltage balancer in BDCMG. The DIDO converter has dual-input sources and a dual-output port connected to the grid. Additionally, the DIDO converter simultaneously performs independent bidirectional power control and voltage balancing control. Based on the input voltages, this paper proposes modulation methods for three cases. The modulation method of the second case has a wide operating range and low balancing current ripple without increasing the switching frequency. Moreover, only voltage balancer mode without active input sources is proposed, considering the intermittent source. Therefore, it can operate as a voltage balancer under all conditions. The voltage balancing performance of the three cases was analyzed. Finally, the proposed modulation and control method of the DIDO converter were verified through experimental results.

24 November 2023 in Energies
Verified
Journal Article
Open access
PDF file
HBHyung-Jun Byun
Hyung-Jun Byun
JPJung-Min Park
Jung-Min Park
JYJunsin Yi
Junsin Yi
CWChung-Yuen Won
Chung-Yuen Won
This study aims to analyze the zero-voltage-switching (ZVS) region of a Triple-Active-Bridge (TAB) converter with five degrees of freedom. A TAB converter is an isolated converter derived from a dual-active-bridge (DAB) converter and composed of three full bridges (FBs) coupled to three winding transformers. To reduce the switching loss of the 12 active switches that compose 3 FBs, the ZVS operation is essential. However, owing to the numerous operation modes derived by five-phase shift ratios, ZVS analysis is complicated, particularly in the time domain. Therefore, this study presents the ZVS analysis model of the TAB converter based on the generalized harmonic approximation (GHA). Through the GHA of a TAB converter, the proposed model consists of unified formulas applicable to all operating ranges of the converter. Unified formulas consider all parameters, such as series inductance, port voltage, parasitic capacitance, transformer voltage, and turn ratio. In the proposed model, the ZVS area is confirmed using five-phase ratios with voltage modulation ratios as variables and verified using MATLAB and experiments.

8 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
JPJung-Min Park
Jung-Min Park
HBHyung-Jun Byun
Hyung-Jun Byun
SKSung-Hun Kim
Sung-Hun Kim
SKSi-Hwan Kim
Si-Hwan Kim
CWChung-Yuen Won
Chung-Yuen Won
Ensuring a protection scheme in a DC distribution system is more difficult to achieve against pole-to-ground faults than in AC distribution system because of the absence of zero crossing points and low line impedance. To complement the major obstacle of limiting the fault current, several compositions have been proposed related to mechanical switching and solid-state switching. Among them, solid-state circuit breakers (SSCBs) are considered to be a possible solution to limit fast fault current. However, they may cause problems in circuit complexity, reliability, and cost-related troubles because of the use of multiple power semiconductor devices and additional circuit configuration to commutate the current. This paper proposes a SSCB with a coupled inductor (SSCB-CI) that has a symmetrical configuration. The circuit is comprised of passive components like commutation capacitors, a CI, and damping resistors. Thus, the proposed SSCB-CI offers the advantages of a simple circuit configuration and fewer utilized power semiconductor devices than the other typical SSCBs in the DC microgrid. For the analysis, six operation states are described for the voltage across the main switches and fault current. The effectiveness of the SSCB-CI against the short-circuit fault is proved via simulation and experimental results in a lab-scale prototype.