3 March 2021 in IEEE Transactions on Sustainable Energy
This paper introduces the modelling foundations to study the fast frequency response (FFR) from utility-scale hydrogen electrolyzers (HEs). Specifically, we propose a dynamic model of the HE electrolysis stack, power-electronics interface, and downstream hydrogen process operational constraints, which is suitable for system-level frequency dynamics studies. We then model and study HE FFR dependency on pre-contingency operating point, size, converter's overloading capability, network location, and active power-frequency controller. Different case studies are run on the Australian multi-area test system via dynamic simulations of a 2030 scenario with 50% renewables and in the context of the August 2018 separation event. Our modelling and results illustrate how grid-scale HEs could support a more secure and resilient operation of low-carbon systems for both credible and extreme outages and the role of different design setups and operating conditions and constraints.
10 June 2022 in IEEE Transactions on Power Systems
This paper presents the modeling foundations to study the capabilities of hydrogen electrolyzers (HEs) to provide frequency control ancillary services (FCAS), including virtual inertia and primary and secondary frequency response. To do so, we propose a general, unified HE dynamic model for the electrolyzer stack circuit, power-electronics interface (PEI), and relevant converter-level control loops. The equivalent circuit of the stack is derived from its current transfer function, with poles and zero obtained from its step response characteristics (e.g., rise/settling time). The stack model also considers relevant physical nonlinearities and downstream hydrogen buffer/process operational constraints. The PEI control loops account for stack model parameters, hydrogen production operational constraints, stack temperature dynamics, and active power reference generation strategy for contingency and regulation frequency support services. Further, we propose a virtual synchronous machine (VSM) control approach to study the VSM HE capabilities to also provide virtual inertia response. We apply the modeling to both alkaline and proton exchange membrane (PEM) technologies, including design of appropriate control schemes. Finally, we assess the FCAS performance of alkaline and PEM HEs via dynamic simulation of the Australian south-east interconnection in a 50%-renewable scenario, also discussing comparison and cooperation with battery energy storage systems.
25 April 2023 in IEEE Transactions on Sustainable Energy
Hydrogen electrloyzers are power-to-gas storage devices that can facilitate large-scale integration of intermittent renewable sources into the future power systems. Due to their fast response and capability to operate in different loading conditions, they can be used as responsive loads providing support to AC grid during transients. This paper suggests taking one step further and using hydrogen electrolyzers to provide grid-forming services to the grid. As a result, the electrolyzer's role is elevated from supporting the grid (responsive load) to actively participating in forming voltage and frequency of the grid. The grid-forming capability of electrolyzer is linked to its hydrogen production constraints, which can potentially pose limitations on the grid-forming services. Besides the grid-forming mode, two additional operating modes, i.e., DC voltage mode and constant power mode, are proposed to ensure a safe operation of the electrolyzer in case of adversary interaction between grid-forming operation and hydrogen production constraints. This paper also studies the impacts of grid-forming services on the electrolyzer's physical features such as hydrogen stack temperature and efficiency. Comprehensive simulations are conducted on a low-inertia test network whose topology is inspired by a portion of the transmission grid in South Australia to confirm the effectiveness of the proposed concept under various operational conditions of the electrolyzer and upstream AC grid. Moreover, the practical feasibility of the proposed control system is experimentally validated by conducting hardware-in-the-loop tests.
28 April 2021 in IEEE Transactions on Power Systems
Utility-scale battery energy storage system (BESS) technologies have huge potential to support system frequency in low-inertia conditions via fast frequency response (FFR) as well as system voltage via dynamic reactive power response. However, technical challenges may emerge in weak grids where low system strength could cause voltage instability, eventually potentially hindering provision of FFR too. This paper provides a systematic and comprehensive analysis of the challenges, and proposes relevant solutions, for BESS in providing FFR and general dynamic active and reactive responses under low system strength conditions. In particular, first we propose a constraint to describe the negative impact of low system strength on BESS phase-locked loop (PLL) stability and possible mitigation solutions. We then investigate the negative impact of large contingencies on BESS DC-link stability and active power control by introducing d-q current-power sensitivity factors and propose a solution based on reactive power prioritization that prevents converter-level instabilities while providing simultaneous active and reactive dynamic responses. Possible negative active/reactive power interactions due to BESS converter capacity constraints and the impact of the BESS operating point are also addressed. All these issues are investigated, and the proposed solutions tested, through explicit mathematical modelling as well as dynamic simulations of the South Australia's Eyre Peninsula weak grid.
1 September 2018 in Journal of the Franklin Institute
11 January 2022 in IEEE Transactions on Power Systems
This work presents the modelling fundamentals to study the dynamics of inverter-based resources (IBRs) in weak distribution grids and derive disturbance performance characteristics describing how they should behave under different conditions. More specifically, with respect to small-signal disturbances we study the possible voltage violations following frequency response from IBRs due to low system strength and also propose specific design requirements for IBR d–q current control to guarantee a stable response. In the context of large-signal disturbances, we highlight how active power-voltage control may not be effective due to a delay imposed by the physical features of the distribution network. Further, we mathematically discuss how IBR reactive power control could enhance its phase-locked loop stability. The proposed disturbance performance characteristics are then integrated into the IBR converter control via a novel voltage-priority reference generation strategy. Simulation results on a real Australian network show the efficacy of the proposed operational and control design requirements, and highlight possible unexpected active/reactive power interactions in weak distribution grids.