Fangjun Bao

Dr. Fangjun Bao


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
YXYue Xin
Yue Xin
BLBernardo T. Lopes
Bernardo T. Lopes
JWJunJie Wang
JunJie Wang
JWJie Wu
Jie Wu
MZManMan Zhu
ManMan Zhu
AEAhmed Elsheikh
Ahmed Elsheikh
Purpose: The objective of this study is to evaluate the in vivo corneal biomechanical response to three laser refractive surgeries.Methods: Two hundred and twenty-seven patients who submitted to transepithelial photorefractive keratectomy (tPRK), femtosecond laser-assisted in-situ keratomileusis (FS-LASIK), or small-incision lenticule extraction (SMILE) were included in this study. All cases were examined with the Corvis ST preoperatively (up to 3 months) and postoperatively at 1, 3, and 6 months, and the differences in the main device parameters were assessed. The three groups were matched in age, gender ratio, corneal thickness, refractive error corrections, optical zone diameter, and intraocular pressure. They were also matched in the preoperative biomechanical metrics provided by the Corvis ST including stiffness parameter at first applanation (SP-A1), integrated inverse radius (IIR), deformation amplitude (DA), and deformation amplitude 2 mm away from apex and the apical deformation (DARatio2mm).Results: The results demonstrated a significant decrease post-operation in SP-A1 and significant increases in IIR, DA, and DARatio2mm (p < 0.05), all of which indicated reductions in overall corneal stiffness. Inter-procedure comparisons provided evidence that the smallest overall stiffness reduction was in the tPRK group, followed by the SMILE, and then the FS-LASIK group (p < 0.05). These results remained valid after correction for the change in CCT between pre and 6 months post-operation and for the percentage tissue altered. In all three surgery groups, higher degrees of refractive correction resulted in larger overall stiffness losses based on most of the biomechanical metrics.Conclusion: The corneal biomechanical response to the three surgery procedures varied significantly. With similar corneal thickness loss, the reductions in overall corneal stiffness were the highest in FS-LASIK and the lowest in tPRK.

27 March 2014 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
YLYi Li
Yi Li
FBFangjun Bao
Fangjun Bao
The purpose of this study was to evaluate the interocular symmetry of several biometric parameters between both eyes. The symmetry between the right and left eye of 397 subjects in 14 biometric parameters, spherical equivalent of refractive error (SE), Jackson crossed cylinder power of refractive error astigmatism with axes at 90° and 180° (RJ0) and at 45° and 135° (RJ45), best-corrected visual acuity (BCVA), average corneal curvature (CC), Jackson crossed cylinder power of corneal astigmatism (CJ0 and CJ45), corneal asphericity coefficient (Q), intraocular pressure (IOP), central corneal thickness (CCT), axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and vitreous chamber depth (VCD), was assessed by comparative data analysis. Aside from RJ0 (p = 0.00), RJ45 (p = 0.02) and Q (p = 0.00), the overall interocular differences of other biometric parameters between fellow eyes were not significant (p > 0.05). The interocular correlation and Bland-Altman plots showed a good agreement between fellow eyes in 14 biometric parameters. Correlations between interocular differences in SE and that in RJ0 (p = 0.03), CC (p = 0.00), AL (p = 0.00) and VCD (p = 0.00) were statistically significant. There were similar strong linear relationships between refractive error astigmatism vectors and corneal astigmatism vectors in bilateral eyes. There were negative correlations of RJ45 and CJ45 between bilateral eyes. A potentially clinically important interocular symmetry in SE, BCVA, CC, CJ0, CJ45, IOP, CCT, AL, ACD, LT and VCD is found in this research, while the differences of RJ0, RJ45 and Q between left and right eyes seem a bit large. The negative interocular relationships of RJ45 and CJ45 demonstrate moderate mirror symmetry exists among fellow eyes. High interocular symmetry in bilateral eyes may be helpful in intraocular lens power calculation, intraocular pressure evaluation, post-operative visual acuity and refraction prediction at the time the fellow eye is undergoing refractive surgery.

31 March 2023 in Frontiers in Neuroscience
Verified
Journal Article
Open access
LFLei Fan
Lei Fan
JWJunjie Wang
Junjie Wang
QLQi Li
Qi Li
ZSZhenhao Song
Zhenhao Song
JDJinhui Dong
Jinhui Dong
Xiaofei WangXiaofei Wang
Xiaofei Wang
This study aimed to investigate the eye movement characteristics and visual fatigue of virtual reality games with different interaction modes. Eye movement data were recorded using the built-in eye tracker of the VR device and eye movement parameters were calculated from the recorded raw data. The Visual Fatigue Scales and Simulator Sickness Questionnaire were used to subjectively assess visual fatigue and overall discomfort of the VR experience. Sixteen male and 17 female students were recruited for this study. Results showed that both the primary and 360 mode of VR could cause visual fatigue after 30 min of gameplay, with significant differences observed in eye movement behavior between the two modes. The primary mode was more likely to cause visual fatigue, as shown by objective measurements of blinking and pupil diameter. Fixation and saccade parameters also showed significant differences between the two modes, possibly due to the different interaction modes employed in the 360 mode. Further research is required to examine the effects of different content and interactive modes of VR on visual fatigue, as well as to develop more objective measures for assessing it.

22 January 2015 in Eye and Vision
Verified
Journal Article
Open access
PDF file
DWDominic Williams
Dominic Williams
Yalin ZhengYalin Zheng
Yalin Zheng
FBFangjun Bao
Fangjun Bao
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh
Optical coherence tomography (OCT) is a non-invasive imaging system that can be used to obtain images of the anterior segment. Automatic segmentation of these images will enable them to be used to construct patient specific biomechanical models of the human eye. These models could be used to help with treatment planning and diagnosis of patients. A novel graph cut technique using regional and shape terms was developed. It was evaluated by segmenting 39 OCT images of the anterior segment. The results of this were compared with manual segmentation and a previously reported level set segmentation technique. Three different comparison techniques were used: Dice’s similarity coefficient (DSC), mean unsigned surface positioning error (MSPE), and 95% Hausdorff distance (HD). A paired t-test was used to compare the results of different segmentation techniques. When comparison with manual segmentation was performed, a mean DSC value of 0.943 ± 0.020 was achieved, outperforming other previously published techniques. A substantial reduction in processing time was also achieved using this method. We have developed a new segmentation technique that is both fast and accurate. This has the potential to be used to aid diagnostics and treatment planning.

1 March 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
WLWeicong Lu
Weicong Lu
YLYue Li
Yue Li
GSGiacomo Savini
Giacomo Savini
BSBenhao Song
Benhao Song
QHQingjie Hu
Qingjie Hu
JHJinhai Huang
Jinhai Huang
To assess the repeatability and agreement of anterior segment measurements between an optical biometer (IOLMaster 700) using swept-source optical coherence tomography and a Scheimpflug-Placido tomographer (Sirius) in patients scheduled for corneal refractive surgery. Eye Hospital of Wenzhou Medical University, Zhejiang, China. Prospective case series. The parameters, including the central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth, keratometry (K) values, astigmatism, J0 (Jackson cross-cylinder with axes at 180 degree and 90 degrees) and J45 vectors (Jackson cross-cylinder with axes at 45 degrees and 135 degrees), and horizontal corneal diameter, were measured 3 times per instrument. The intraobserver repeatability was assessed using test-retest repeatability, the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Paired t tests were used to compare the difference between the 2 methods. Agreement was evaluated using Bland-Altman analyses. The study enrolled 100 right eyes. All measurements of the 2 devices showed high repeatability. The CoV of all measured parameters was less than 0.93 and the ICC value was more than 0.85. The paired t test did not show a significant difference in CCT, astigmatism, J0 or J45 vector. The mean ACD and aqueous depth were statistically lower with the optical biometer; however, the 95% limits of agreement (LoA) were low (from -0.20 to -0.03 mm). The K and corneal diameter values obtained using the optical biometer were higher by 0.1 diopter and 0.1 mm, respectively, but with narrow 95% LoA. The optical biometer and the Scheimpflug-Placido tomographer showed high repeatability for all anterior segment measurements. The measured parameters showed good agreement and could be used interchangeably.

24 October 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
YMYuan-Yuan Miao
Yuan-Yuan Miao
XMXiao-Min Ma
Xiao-Min Ma
ZQZhan-Xin Qu
Zhan-Xin Qu
AEAshkan Eliasy
Ashkan Eliasy
BWBo-Wen Wu
Bo-Wen Wu
FBFangjun Bao
Fangjun Bao
This study seeks to evaluate the ability of the updated stress strain index (SSIv2) and other Corvis ST biomechanical parameters in distinguishing between keratoconus at different disease stages and normal eyes. Diagnostic accuracy analysis to distinguish disease stages. 1084 eyes were included and divided into groups of normal (199 eyes), forme fruste keratoconus (FFKC, 194 eyes), subclinical keratoconus (SKC, 113 eyes), mild clinical keratoconus (CKC-Ⅰ, 175 eyes), moderate clinical keratoconus (CKC-Ⅱ, 204 eyes), and severe clinical keratoconus (CKC-Ⅲ, 199 eyes). Each eye was subjected to a Corvis ST examination to determine the central corneal thickness (CCT), biomechanically corrected intraocular pressure (bIOP), SSIv2 (updated stress-strain index), and other 8 Corvis parameters including the stress-strain index (SSIv1), stiffness parameter at first applanation (SP-A1), first applanation time (A1T), Ambrósio relational thickness to the horizontal profile (ARTh), integrated inverse radius (IIR), maximum deformation amplitude (DAM), ratio between deformation amplitude at the apex and at 2 mm nasal and temporal (DARatio2), and Corvis biomechanical index (CBI). The sensitivity and specificity of these parameters in diagnosing keratoconus were analyzed through receiver operating characteristic curves. Before and after correction for CCT and bIOP, SSIv2 and ARTh were significantly higher and IIR and CBI were significantly lower in the normal group than in the FFKC group, SKC group and the 3 CKC groups (all P < .05). There were also significant correlations between the values of SSIv2, ARTh, IIR, CBI, and the CKC severity (all P < .05). AUC of SSIv2 was significantly higher than all other Corvis parameters in distinguishing normal eyes from FFKC, followed by IIR, ARTh and CBI. Corvis ST's updated stress-strain index, SSIv2, demonstrated superior performance in differentiating between normal and keratoconic corneas, and between corneas with different keratoconus stages. Similar, but less pronounced, performance was demonstrated by the IIR, ARTh and CBI.