Stijn Van de Putte

Mr. Stijn Van de Putte

Architecture & Urban Planning, Ghent University, Ghent, Belgium
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Building and Environment
Verified
Journal Article
Closed access
LGLisa Van Gulck
Lisa Van Gulck
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
MDMarc Delghust
Marc Delghust
NBnathan Van Den Bossche
nathan Van Den Bossche
MSMarijke Steeman
Marijke Steeman

1 November 2015 in Energy Procedia
Verified
Journal Article
Open access
EHEline Himpe
Eline Himpe
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
JLJelle Laverge
Jelle Laverge
AJArnold Janssens
Arnold Janssens
The first year commissioning activities in 4 multi-family buildings from a zero-carbon neighbourhood is presented, with focus on the operation of the ventilation systems, the indoor climate and user acceptance. The key parameters to detect the main system failures are identified and the effect of the detected defects and failures on the energy performance of the dwellings is explored using dynamic simulations and monitoring data. It is concluded that commissioning of the building systems during occupancy is a vital part of the operational lifetime of a building project in order to achieve the high building performance targets in reality

30 June 2020 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
WBWolf Bracke
Wolf Bracke
MDMarc Delghust
Marc Delghust
MSMarijke Steeman
Marijke Steeman
AJArnold Janssens
Arnold Janssens
Often there is a significant difference between the actually measured and theoretically calculated energy use. The deviation between the two can be a result of errors in design, construction or commissioning, due to the technical performance of building components and installations that don’t meet the design requirements. But equally, incorrect assumptions in the calculation can largely affect the results, for example the user influence that is simulated in a different way. This paper presents the analysis of data from an on-site monitoring system of two case study multi-family buildings that were deeply refurbished. It points out that the calculated energy use for space heating was largely underestimated, while there was an overestimation of the energy use for domestic hot water. The high indoor temperature and the low occupancy of the apartments were identified as the key parameters to explain this striking difference between the theoretical design and the actual situation.

1 January 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
MSMarijke Steeman
Marijke Steeman
AJArnold Janssens
Arnold Janssens
The building energy performance gap, resulting from a discrepancy between the actual energy use and theoretical calculations, remains a persistent issue in building design. This study examines the energy performance of three multifamily buildings with a collective heating system powered by gas boilers and solar collectors: two that underwent deep renovation and one newly built. An extensive on-site monitoring system provides detailed data on both the heating demand and the final energy use. To ensure comparability, the total energy use of each unit is normalised using the energy signature method. The findings show the large spread of actual energy demands due to a wide variation in user profiles. The majority of dwellings have an actual energy use that is significantly higher than calculated, which is largely attributable to space heating. The gap is further exacerbated by substantial heat losses within the building’s heating system and by limited gains from the solar collectors, indicating discrepancies between design models and operational realities. To bridge this gap, there is a need for rigorous commissioning processes, at least during the initial operation phase start-up and ideally continuously. This can ensure more effective utilisation of renewable energy sources and reduce energy inefficiencies.

30 June 2020 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
LGLisa Van Gulck
Lisa Van Gulck
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
NBNathan Van Den Bossche
Nathan Van Den Bossche
MSMarijke Steeman
Marijke Steeman
This paper examines the environmental and financial impact of façade renovation strategies designed for change and how taking into account each of these aspects will lead to different renovation decisions. In a first part of the paper the optimal construction method for different façade renovation strategies is searched from the environmental point of view. This is done through life cycle analysis (LCA). In a second part of the paper the financial impact of the results obtained with LCA is determined. This is done with life cycle costing (LCC). The results show that although both LCA and LCC are life cycle studies that follow similar principles and boundaries this does not mean that LCA and LCC based decisions will coincide. For the environmental score the operational energy of a building has the largest impact and energy efficiency measures will often be beneficial. For the financial cost the investment cost is the most important impact and energy efficiency measures will only pay off to a certain extent. Decisions that are based solely on the financial cost may thus lead to sub-optimal solutions from an environmental point of view.

6 December 2024
Verified
Book Chapter
Closed access
PDF file
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
NMNiels Maenhout
Niels Maenhout
MSMarijke Steeman
Marijke Steeman
AJArnold Janssens
Arnold Janssens