Marc Delghust

Marc Delghust

Auto-generated profile, based on publicly available information

Marc Delghust

Ghent University Belgium

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
SHSam Hamels
Sam Hamels
EHEline Himpe
Eline Himpe
JLJelle Laverge
Jelle Laverge
MDMarc Delghust
Marc Delghust
KBKjartan Van Den Brande
Kjartan Van Den Brande
JAJohan Albrecht
Johan Albrecht

1 May 2013 in Building Research & Information
Verified
Journal Article
Closed access
EHEline Himpe
Eline Himpe
LTLeen Trappers
Leen Trappers
WDWim Debacker
Wim Debacker
MDMarc Delghust
Marc Delghust
JLJelle Laverge
Jelle Laverge
MHMarlies Van Holm
Marlies Van Holm
Most zero-energy concepts focus on a reduction of the non-renewable operational energy use in buildings rather than taking the reduction of their life cycle energy use as a starting point. Nevertheless, the life cycle embodied and end-of-life energy will become more important, especially in buildings with low operational energy. Therefore, the life cycle energy use of a Belgian zero-energy reference house is examined by means of life cycle energy assessment. The influence of design decisions and regulations on the building construction type, the building services, and the performance of the building envelope are investigated. In terms of thermal performance of the building, the results show that the life cycle embodied energy in zero-energy houses with passive or standard thermal performance was not substantially different. From a life cycle energy perspective, passive house requirements are not essential criteria for zero-energy houses in Belgium. On the other hand, large life cycle energy savings were obtained through a proficient selection of all building construction materials and services. For the life cycle embodied energy in building constructions, the best timber frame and masonry houses were equally efficient. Wood pellets and photovoltaic panels were decisive factors in the life cycle embodied energy of building services. Les concepts <> sont axés pour la plupart sur une réduction de l'utilisation de l'énergie d'exploitation non renouvelable dans les bâtiments plutôt que de prendre la réduction de leur consommation d'énergie sur le cycle de vie comme point de départ. Néanmoins, l'énergie grise sur le cycle de vie et l'énergie de fin de vie vont gagner en importance, en particulier dans les bâtiments nécessitant une faible énergie d'exploitation. La consommation d'énergie sur le cycle de vie d'une maison belge «zéro énergie» de référence est donc étudiée au moyen d'un bilan énergétique du cycle de vie. Sont étudiés l'influence des décisions de conception et de la réglementation sur le type de construction du bâtiment, les services au bâtiment, et les performances de l'enveloppe du bâtiment. En termes de performance thermique du bâtiment, les résultats montrent que l'énergie grise sur le cycle de vie n'était pas fondamentalement différente dans les maisons «zéro énergie» offrant des performances thermiques passives ou standard. Du point de vue de l'énergie du cycle de vie, les exigences d'une maison passive ne sont pas des critères essentiels pour des maisons «zéro énergie» en Belgique. En revanche, d'importantes économies d'énergie sur le cycle de vie ont été obtenues par un choix opéré avec compétence de tous les matériaux de construction et services au bâtiment. S'agissant de l'énergie grise sur le cycle de vie dans la construction de bâtiments, les meilleures maisons, qu'elles aient été à ossature bois ou en maçonnerie, ont été tout aussi performantes. Les granulés de bois et les panneaux photovoltaïques ont été des facteurs décisifs concernant l'énergie grise sur le cycle de vie des services aux bâtiments. Mots clés: services aux bâtiments, énergie grise, analyse énergétique du cycle de vie, [construction] passive, bâtiments résidentiels, <>

26 May 2021 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
CLChenxi Liao
Chenxi Liao
MDMarc Delghust
Marc Delghust
PWPawel Wargocki
Pawel Wargocki
JLJelle Laverge
Jelle Laverge
The effects of two window states (closed or open) on the bedroom environment and on sleep quality were investigated. Twenty-seven subjects (14 males and 13 females, 20–33 years old) without sleep disorders and chronic diseases participated. The subjects slept for two consecutive nights with windows open and two consecutive nights with windows closed in four dormitory rooms adapted for the purpose of this study, one person at a time. The order of exposure was balanced among participants. Bed temperature, room temperature, relative humidity (RH), carbon dioxide (CO2), particles (PM2.5), and noise were monitored during sleep. Sleep quality was measured using subjective ratings, a wrist-worn sleep tracker, and (for one group of 14 subjects only) polysomnography (PSG) for home use; snoring in this sub-group and awakenings were also registered. Higher PM2.5 and noise levels were found with windows open, while higher room temperature, RH, and CO2 levels were measured with windows closed. There were no differences between conditions in terms of objectively measured sleep stages but the subjects with the PSG attached snored significantly less and woke up significantly less often when sleeping with windows open. Start sleep time, end sleep time, total sleep time (TST) and time in bed (TIB) measured with the sleep tracker were confirmed by the measurements made using PSG, light sleep (N1 + N2) and sleep latency were in moderate agreement but there was no significant agreement for REM and deep sleep (N3). When sleeping with windows open, the subjects rated the air as fresher but reported higher noise levels, feeling less rested, a worse mental state and well-being, and their replies on the Groningen sleep quality scale indicated poorer sleep quality. There was no clear association between the performance test score and sleep quality. These results suggest that sleeping with windows open can provide some benefits by increasing ventilation with outdoor air, reducing CO2 concentrations, improving air quality as indicated by the subjectively rated air freshness and some of the parameters defining sleep quality, but it may also result in some discomfort if there are episodic loud noise events outdoors. Further studies are required to clarify the role of open windows in achieving good sleep quality.

5 May 2015 in Building Research & Information
Verified
Journal Article
Closed access
MDMarc Delghust
Marc Delghust
WRWina Roelens
Wina Roelens
TTTine Tanghe
Tine Tanghe
YWYves De Weerdt
Yves De Weerdt
AJArnold Janssens
Arnold Janssens
How accurately can official energy performance calculations assess the real energy use in high-performance houses? This question was investigated by analysing 537 dwellings. Data on building characteristics and calculated performance from the Flemish Energy Performance of Buildings (EPB) database were complemented with data from energy utilities and surveys of inhabitants, their socio-demographic characteristics and user behaviours. While the real and theoretical energy uses were strongly correlated, the official calculation method overestimated the heating energy use of most houses while neglecting important electricity end uses. The prediction error varied strongly between individual cases. Two options within the calculation procedure had a significant impact on these prediction errors: the use of default values for the air tightness of the building envelope and the reported return temperature of the space heating system. The simplified calculation of net domestic hot water consumption and the real heating of the master bedrooms also affected prediction accuracy. However, extrapolations are hazardous due to the risk of selection and non-response biases implied by the approach and the need for further research into the causalities. Nonetheless, the findings stress the importance of accurate input data and realistic default values for calculation models used for high-performance buildings.

1 October 2020 in Building and Environment
Verified
Journal Article
Closed access
LGLisa Van Gulck
Lisa Van Gulck
Stijn Van de PutteStijn Van de Putte
Stijn Van de Putte
MDMarc Delghust
Marc Delghust
NBnathan Van Den Bossche
nathan Van Den Bossche
MSMarijke Steeman
Marijke Steeman

31 August 2022 in Building Research & Information
Verified
Journal Article
Closed access
MHMatthias Van Hove
Matthias Van Hove
MDM. Deurinck
M. Deurinck
WLW. Lameire
W. Lameire
JLJ. Laverge
J. Laverge
AJArnold Janssens
Arnold Janssens
MDM. Delghust
M. Delghust
Large-scale statistical studies on the gap between the real and regulatory energy use in residential buildings in Europe have shown that the regulatory calculation overestimated the real energy use, inflated true energy savings and undermined national energy policy making. Using data from 122,680 Flemish existing single-family houses, this research builds further on existing studies by contributing results for Flanders. The study also examines to what extent available aggregated variables explain the real annual total building energy use using statistical linear models and addresses the problem of multicollinearity and the importance of bootstrapped confidence intervals for model quality control. The overestimation of the real total energy use (and potential energy savings) by the Flemish regulatory method is exceedingly large compared to studies from other EU countries. The Flemish labels prove very poor indicators of the real energy use. Statistical linear models explain up to 46.6% of all variability and indicate that a significant extent of multicollinearity had to be corrected. Half of the variability has been left unexplained and has to be attributed to variables that were not available and the fact that the data were insufficiently accurate. Future analysis will explore whether more complex models identify more evidence.