Daniel Ch. Haspinger

Dr. Daniel Ch. Haspinger

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2021 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
DHDaniel Ch. Haspinger
Daniel Ch. Haspinger
SKSandra Klinge
Sandra Klinge
Gerhard A. HolzapfelGerhard A. Holzapfel
Gerhard A. Holzapfel
The interior of a eukaryotic cell is a highly complex composite material which consists of water, structural scaffoldings, organelles, and various biomolecular solutes. All these components serve as obstacles that impede the motion of vesicles. Hence, it is hypothesized that any alteration of the cytoskeletal network may directly impact or even disrupt the vesicle transport. A disruption of the vesicle-mediated cell transport is thought to contribute to several severe diseases and disorders, such as diabetes, Parkinson’s and Alzheimer’s disease, emphasizing the clinical relevance. To address the outlined objective, a multiscale finite element model of the diffusive vesicle transport is proposed on the basis of the concept of homogenization, owed to the complexity of the cytoskeletal network. In order to study the microscopic effects of specific nanoscopic actin filament network alterations onto the vesicle transport, a parametrized three-dimensional geometrical model of the actin filament network was generated on the basis of experimentally observed filament densities and network geometries in an adenocarcinomic human alveolar basal epithelial cell. Numerical analyzes of the obtained effective diffusion properties within two-dimensional sampling domains of the whole cell model revealed that the computed homogenized diffusion coefficients can be predicted statistically accurate by a simple two-parameter power law as soon as the inaccessible area fraction, due to the obstacle geometries and the finite size of the vesicles, is known. This relationship, in turn, leads to a massive reduction in computation time and allows to study the impact of a variety of different cytoskeletal alterations onto the vesicle transport. Hence, the numerical simulations predicted a 35% increase in transport time due to a uniformly distributed four-fold increase of the total filament amount. On the other hand, a hypothetically reduced expression of filament cross-linking proteins led to sparser filament networks and, thus, a speed up of the vesicle transport.

Verified
Journal Article
Open access
PDF file
MKMarcela Kuniakova
Marcela Kuniakova
ZNZuzana Varchulová Nováková
Zuzana Varchulová Nováková
DHDaniel Ch. Haspinger
Daniel Ch. Haspinger
JNJustyna A. Niestrawska
Justyna A. Niestrawska
MKMartin Klein
Martin Klein
SŽStanislav Žiaran
Stanislav Žiaran
This study evaluates the effects of two decellularization protocols, enzyme-detergent (ED) and detergent-detergent (DD), on the structural and biomechanical properties of human urethral tissue. Urethral samples from 18 individuals were divided into ED (n = 7) and DD (n = 11) groups, with native samples (n = 3) serving as controls. Histological and ultrastructural analyses confirmed that both protocols effectively removed cellular content while preserving essential extracellular matrix (ECM) elements, such as collagen and elastic fibers. Immunohistochemical staining for collagen IV and fibronectin revealed no significant differences between decellularized and native tissues, indicating intact ECM structure. Biomechanical testing demonstrated that DD-treated tissues had significantly lower Cauchy stress (1494.8 ± 518.4 kPa) when compared to native tissues (2439.7 ± 578.7 kPa, p = 0.013), while ED-treated tissues were similar to both groups. Both decellularized groups exhibited reduced stretch at failure and elastic modulus compared to native tissues. Cytotoxicity assays using adipose-derived stem cells demonstrated no signs of toxicity in either protocol. Overall, both ED and DD protocols effectively preserved the urethral ECM structure and mechanical properties, making them suitable for potential use in tissue-engineered grafts and for biobanking purposes. Further research is needed to refine and optimize decellularization methods to improve scaffold recellularization and ensure clinical safety and efficacy.

15 November 2025 in Injury
Verified
Journal Article
Open access
AMAnnika Hela Meuser
Annika Hela Meuser
Andreas HöchAndreas Höch
Andreas Höch
PHPetr Henyš
Petr Henyš
CKChristian Kleber
Christian Kleber
DHDaniel Ch. Haspinger
Daniel Ch. Haspinger
NHNiels Hammer
Niels Hammer
This study aimed to analyse the load-deformation behaviour of pelves treated with external fixation following AO61C1.3a pelvic injury. Designing a biomechanical setup , the load-bearing capacity of pelves was assessed across varying pin configurations (two, three, or four external fixator pins). Mechanical parameters such as stiffness, peak-to-peak, valley-to-valley, fracture line, total displacement, deformation, and maximum load were derived to quantify pelvis stability. The 3-pin configuration demonstrated superior stability with significantly smaller pubis and sacral fracture displacements under all loading conditions (p<0.001), and was the only configuration below the clinical failure threshold. Notably, this configuration minimised fracture movement despite global outcome parameters showing no significant differences between the groups. These findings highlight the importance of fracture-specific stability over global stiffness in ensuring effective fixation. The results indicate that optimal biomechanical resistance to C1.3a pelvic instability is achieved through a combination of two pins on the injured side and a single pin on the stable hemipelvis using contemporary pin devices. This study offers the biomechanical basis required to facilitate the design and execution of clinical trials addressing pelvic ring injuries.

23 September 2026 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SOSabine Otto
Sabine Otto
CRCarolina Radetzky
Carolina Radetzky
DHDaniel Ch. Haspinger
Daniel Ch. Haspinger
NJNorbert Jakse
Norbert Jakse
JNJustyna A. Niestrawska
Justyna A. Niestrawska
VAVeronica Alexandra Antipova
Veronica Alexandra Antipova
This study investigated the regional and direction-specific tensile properties of native human oral mucosal tissues. Tissue specimens were harvested from three distinct maxillary regions, namely the hard palate, attached gingiva, and alveolar mucosa from 11 partially dentate donors, totaling 34 specimens. Using the osmotic stress protocol to standardize water content, specimens underwent uniaxial tensile testing. Mechanical parameters, including elastic modulus, Cauchy stress and stretch at failure, were calculated and statistically analyzed. The attached gingiva yielded a higher elastic modulus than the alveolar mucosa and a greater Cauchy stress at failure than both the alveolar mucosa and the hard palate, while stretch at failure was similar across all regions examined. No statistically significant direction-dependent differences were detected within the investigated regions. The attached gingiva demonstrated greater variability in elastic modulus and stress values. Collagen fiber coherency and rupture patterns differed between anatomical regions; however, collagen coherency showed no significant overall correlation with elastic modulus or Cauchy stress at failure. Furthermore, failure patterns appear to be site-specific. The present study constitutes the first comprehensive morpho-mechanical characterization of human maxillary mucosa, thereby providing novel insight into region-specific mechanical resilience. These findings hold significant relevance for the optimization of prosthetic design, the advancement of oral biomechanical understanding, and the refinement of computational models in both clinical and bioengineering contexts.

23 May 2026 in Biology
Verified
Journal Article
Open access
PDF file
DHDaniel Ch. Haspinger
Daniel Ch. Haspinger
SBStefan Budde
Stefan Budde
NHNiels Hammer
Niels Hammer
JZJohannes Zeichen
Johannes Zeichen
Implantation of a femoral stem in total hip arthroplasty alters physiological load transfer within the proximal femur. Short-stem designs aim to preserve bone stock and maintain proximal load sharing, yet the influence of femoral neck resection height and its interaction with femoral morphology on primary stability remain insufficiently understood. This in vitro biomechanical study investigated these effects using 33 human femora classified as Dorr B or C. In a paired design, a cemented calcar-guided short stem was implanted with either a low (standard) or +5 mm higher femoral neck resection. Specimens underwent cyclic fatigue loading to assess reversible and irreversible micromotion and interface strain, followed by ultimate compression to quantify global fixation strength. Primary stability was assessed by reversible and irreversible translation of the prosthetic head center of rotation and by cortical interface strain measurements using digital image correlation. Overall fixation strength and irreversible deformation remained comparable across resection heights and Dorr types. In contrast, resection height and femoral morphology influenced reversible micromotion and interface strain, with higher resection reducing reversible micromotion, particularly in Dorr C femora and shifting lateral interface strain toward compression. These findings suggest that surgical technique and femoral morphology mainly affect local, reversible bone–cement–implant mechanics rather than global fixation strength.