Oscar Silva

Mr. Oscar Silva

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
DMDonato Luna Moreno
Donato Luna Moreno
OSOscar Silva
Oscar Silva
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Mezcal is a traditional Mexican spirit produced by distilling fermented agave, with a unique taste directly related to its volatile compound composition. Thus, the present research proposed the surface plasmon resonance (SPR) technique as a potential method to differentiate mezcals, studying several parameters at angular interrogations and at a fixed angle. The study evaluated eight mezcals from different agave species using SPR and gas chromatography-mass spectrometry (GC-MS). Despite the similarities in mezcal spirits corresponding to the same ethanol content and the same artisanal method, it was possible to obtain well-differentiated characteristics by SPR parameters, such as the width of the curve, the resonant angle, and reflectance intensities. Therefore, it was possible to demonstrate the potential use of the SPR technique as a rapid first approach to a screening test to differentiate types of spirits.

5 December 2024 in Optics
Verified
Journal Article
Open access
PDF file
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
DMDonato Luna Moreno
Donato Luna Moreno
This paper outlines the design and fabrication of a portable optomechatronic system based on the theta-2theta configuration, which explores various optical characterization techniques for transparent materials and dielectric thin films. These techniques include Brewster angle and Abelès-Brewster angle measurements, critical angle measurements, and the surface plasmon resonance technique. The system consists of a mechanical assembly of rotating stages, a semiconductor laser, a photodiode connected to a data acquisition card, and a user interface for controlling the stepper motor rotation stages. Utilizing a BK7 substrate, the motorized stage achieved a resolution of 0.010. The Brewster angle measured was 56.550, with a refractive index (n) of 1.5137. The relative error obtained was Δn/n = 3.82 × 10−4, with a sensitivity of 164.27 RIU/degree and an accuracy of 0.37/degree. Furthermore, the discrepancies between theoretical and experimental refractive indices for different prisms at 639 nm ranged from ±7 × 10−4 to ±73 × 10−4. After testing various samples, the system demonstrated its capability to perform fast, precise, and non-invasive measurements. Its portability allows for use in diverse environments and applications.

15 July 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
DMDonato Luna Moreno
Donato Luna Moreno
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
OSOscar Silva
Oscar Silva
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
Microplastics (MP) have been found not only in the environment but also in living beings, including humans. As an initial step in MP detection, a method is proposed to measure the effective refractive index of a solution containing 5 µm diameter spherical polystyrene particles (SPSP) in distilled water, based on the surface plasmon resonance (SPR) technique and Mie scattering theory. The reflectances of the samples are obtained with their resonance angles and depths that must be normalized and adjusted according to the reference of the air and the distilled water, to subsequently find their effective refraction index corresponding to the Mie scattering theory. The system has an optical sensor with a Kretschmann–Raether configuration, consisting of a semicircular prism, a thin gold film, and a glass cell for solution samples with different concentrations (0.00, 0.20, 0.05, 0.50, and 1.00%). The experimental result provided a good linear fit with an R2 = 0.9856 and a sensitivity of 7.2863 × 10−5 RIU/% (refractive index unit per percentage of fill fraction). The limits of detection (LOD) and limit of quantification (LOQ) were determined to be 0.001% and 0.0035%, respectively. The developed optomechatronic system and its applications based on the SPR and Scattering enabled the effective measurement of the refractive index and concentration of solutions containing 5 µm diameter SPSP in distilled water.

10 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
DMDonato Luna Moreno
Donato Luna Moreno
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
OSOscar Silva
Oscar Silva
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
Microplastics (MP) have been found not only in the environment but also in living beings, including humans. As an initial step in MP detection, a method is proposed to measure the effective refractive index of a solution containing 5 µm diameter spherical polystyrene particles (SPSP) in distilled water, based on surface plasmon resonance (SPR) technique and Mie scattering theory. The reflectances of the samples are obtained with their resonance angles and depths that must be normalized and adjusted according to the reference of the air and the distilled water, to subsequently find its effective refraction index corresponding to the Mie scattering theory. The system has an optical sensor with a Kretschmann-Raether configuration, consisting of a semicircular prism, a thin gold film, and a cell for solutions samples with different concentrations (0.00, 0.20, 0.05, 0.50 and 1.00 %). The experimental result provided a good linear fit with an R2=0.986, a sensitivity of 7.4526 ×10-5 RIU/%, LOD=0.001% and LOQ=0.0035%. The optomechatronic system and the applications developed for the SPR-Scattering theory allowed us to measure the effective refractive index and concentration for solutions with 5 µm diameter SPSP in distilled water.

11 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
AAARACELI SÁNCHEZ ALVAREZ
ARACELI SÁNCHEZ ALVAREZ
OROsvaldo Rodríguez-Quiroz
Osvaldo Rodríguez-Quiroz
GQGabriela Elizabeth Quintanilla-Villanueva
Gabriela Elizabeth Quintanilla-Villanueva
MRMelissa Rodríguez-Delgado
Melissa Rodríguez-Delgado
Juan Francisco Villarreal-ChiuJuan Francisco Villarreal-Chiu
Juan Francisco Villarreal-Chiu
DMDonato Luna Moreno
Donato Luna Moreno
This paper describes the design and fabrication of a portable optomechatronic system based on the theta-2theta system that explores different optical characterization techniques of transparent materials and dielectric thin films, such as Brewster and Abelès-Brewster angle measurements, critical angle measurements, and surface plasmon resonance technique. The system consists of a mechanical system of rotating stages, a semiconductor laser, a photodiode with a data acquisi-tion card, and a user interface to control stepper motor rotation stages. After measuring with different samples, it is demonstrated that the system can perform fast, precise, non-invasive measurements and, being portable, it can be used in different environments and applications.