Andrea Coldea

Dr. Andrea Coldea

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Dental Materials
Verified
Journal Article
Open access
TMTina Maleki
Tina Maleki
JMJohn Meinen
John Meinen
ACAndrea Coldea
Andrea Coldea
MRMarcel Reymus
Marcel Reymus
DEDaniel Edelhoff
Daniel Edelhoff
BSBogna Stawarczyk
Bogna Stawarczyk
To investigate the flexural strength (FS), elastic modulus (E), Martens hardness (HM), water sorption (wsp), water solubility (wsl) and degree of conversion (DC) of 3D-printed, milled and injection molded splint materials. Specimens (N = 1140) were fabricated from five 3D-printed (GR-22 flex, GR-10 guide, ProArt Print Splint clear, V-Print Splint, V-Print Splint comfort), five milled (BioniCut, EldyPlus, ProArt CAD Splint clear, Temp Premium Flexible, Thermeo) and two injection molded (PalaXPress clear, Pro Base Cold) materials. FS, E, HM, wsp, wsl and DC were tested initially (24 h, 37 °C, H2O), after water storage (90 d, 37 °C, H2O) as well as after thermal cycling (5000 thermal cycles, 5/55 °C). Data were analyzed with Kolmogorov-Smirnov, Kruskal- Wallis, Mann-Whitney U test and Spearman's correlation (p < 0.05). Initially, the mean flexural strength values ranged from 1.9 to 90.7 MPa for printed, 3.8 to 107 MPa for milled and 99.7 to 102 MPa for injection molded materials. The initial mean elastic modulus values were 0.0 to 2.4 GPa for printed, 0.1 to 2.7 GPa for milled and 2.8 GPa for injection molded materials. The initial mean Martens hardness values were 14.5 to 126 N/mm2 for printed, 50.2 to 171 N/mm2 for milled and 143 to 151 N/mm2 for injection molded materials. Initially, the mean water sorption values ranged from 23.1 to 41.2 μg/mm3 for printed, 4.5 to 23.5 μg/mm3 for milled and from 22.5 to 23.3 μg/ mm3 for injection molded materials. The initial mean water solubility values ranged from 2.2 to 7.1 μg/mm3 for printed, 0.0 to 0.5 μg/mm3 for milled and 0.1 to 0.3 μg/mm3 for injection molded materials. After water storage and thermal cycling most of the values decreased and some increased. The mean DC values ranged initially from 72.3 to 94.5 %, after water storage from 74.2 to 96.8 % and after thermal cycling from 75.6 to 95.4 % for the printed materials. The mechanical and physical properties of printed, milled and injection molded materials for occlusal devices vary and are influenced by aging processes. For clinical applications, materials need to be chosen according to the specific indications.

1 March 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
ACAndrea Coldea
Andrea Coldea
FMFelicitas Mayinger
Felicitas Mayinger
JMJohn Meinen
John Meinen
MHMoritz Hoffmann
Moritz Hoffmann
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
Studies on the mechanical properties of 3-dimensionally (3D) printed denture base polymers with appropriate test methods are lacking. The purpose of this in vitro study was to determine the flexural strength (σf), elastic modulus (E), fracture toughness (KIC), work of fracture (ωe), and Martens hardness (HM) of 3D printed denture base polymers and to compare them with an injection molded material. Three resins for additive (Lucitone Digital Print, LDP; Flexcera Base, FCB and an experimental material, EXP) and 1 for injection molding (IvoBase Hybrid, IBH) fabrication were analyzed. Standardized specimens were fabricated, polished, tempered, and thermal cycled (5 °C to 55 °C) before testing for σf, E, KIC, ωe, and HM. The results were explored by global analysis (α=.05). The Kolmogorov-Smirnov test was used to test for data distribution. Parametric and nonparametric tests followed by pairwise comparison were applied to test for differences between groups. The σf, E, and HM of 3D printed polymers were significantly lower than those of the injection molded, both for the tempered and aged groups. The σf was lowest for FCB and highest for IBH in the tempered state. The KIC and ωe of the tempered EXP and IBH groups were lower compared with those of FCB and LDP. After aging, EXP, FCB, and IBH presented KIC in the same range, but it was lower than for LDP. Compared with the printable polymers, the control group IBH was not affected by artificial aging. The σf, E, and HM of printable polymers were lower than those of the control group, and specimens did not fracture in bend testing. In contrast, KIC and ωe were the highest for a printable polymer. Therefore, tension tests should be considered when testing ductile materials.

7 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
VLValerie Lankes
Valerie Lankes
MRMarcel Reymus
Marcel Reymus
FMFelicitas Mayinger
Felicitas Mayinger
ACAndrea Coldea
Andrea Coldea
ALAnja Liebermann
Anja Liebermann
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.

10 October 2025 in Materials
Verified
Journal Article
Open access
PDF file
MHMoritz Hoffmann
Moritz Hoffmann
ACAndrea Coldea
Andrea Coldea
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
The aim of this study is to evaluate the mechanical properties and long-term stability of 3D-printable resins for permanent fixed dental prostheses (FDPs), focusing on whether material performance is influenced by 3D-printer type or by differences in resin formulations. Specimens (N = 621) were printed. CAD/CAM blocks (BRILLIANT Crios) served as control. Flexural strength (FS) with elastic modulus (E_calc), Weibull modulus (m), Martens’ hardness (HM), indentation modulus (EIT), elastic modulus (E_RFDA), shear modulus (G_RFDA), and Poisson’s Ratio (ν) were measured initially, after water storage (24 h, 37 °C), and after thermocycling (5–55 °C, 10,000×). SEM analysis assessed microstructure. Data were analyzed using Kolmogorov–Smirnov, ANOVA with Scheffe post hoc, Kruskal–Wallis with Mann–Whitney U, and Weibull statistics with maximum likelihood (α = 0.05). A ceramic crown printed with Midas showed higher FS, HM, and EIT values after thermocycling than with Pro55s, and higher E_calc scores across all aging regimes. A Varseo Smile Crown Plus printed with VarseoXS and AsigaMax showed a higher FS value than TrixPrint2, while AsigaMax achieved the highest initial E_calc and E_RFDA values, and VarseoXS did so after thermocycling. HM, EIT, and G_RFDA were higher for TrixPrint2 and AsigaMax printed specimens, while ν varied by system and aging. 3Delta Crown, printed with AsigaMax, showed the highest FS, E_calc, HM, EIT, and m values after aging. VarseoSmile triniQ and Bridgetec showed the highest E_RFDA and G_RFDA values depending on aging, and Varseo Smile Crown Plus exhibited higher ν initially and post-aging. Printer system and resin formulation significantly influence the mechanical and aging behaviors of 3D-printed FDP materials, underscoring the importance of informed material and printer selection to ensure long-term clinical success.

11 November 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
ACAndrea Coldea
Andrea Coldea
MDMustafa Borga Donmez
Mustafa Borga Donmez
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
To evaluate the effect of firing temperature and heating rate on the volumetric shrinkage, translucency, flexural strength, hardness, and fracture toughness of a zirconia veneering ceramic. Zirconia veneering ceramic specimens (N = 45) with varying final temperatures (730 °C, 750 °C, and 770 °C) and heating rates (70 °C/min, 55 °C/min, and 40 °C/min) were fabricated (n = 5). Each specimen's shrinkage, translucency, flexural strength, hardness, and fracture toughness were determined. Two-way analysis of variance, Scheffé test, and Pearson's correlation analysis were used to evaluate data (α = 0.05). The shrinkage (44.9 ± 3.1-47.5 ± 1.6 vol%) and flexural strength (74.1 ± 17.4-107.0 ± 27.1 MPa) were not affected by tested parameters (P ≥ 0.288). The interaction between the main factors affected the translucency, hardness, and fracture toughness of the specimens (P ≤ 0.007). Specimens with 770 °C final temperature and 70 °C/min heating rate had the lowest (21.8 ± 3.2 %) translucency (P ≤ 0.039). The hardness ranged between 4.98 ± 0.51 GPa (730 °C; 70 °C/min) and 5.60 ± 0.37 GPa (770 °C; 70 °C/min). Fracture toughness ranged between 0.54 ± 0.04 MPa√m and 0.67 ± 0.08 MPa√m with the highest values for specimens fired at 730 °C with 70 °C/min (P ≤ 0.001). There was a positive correlation between translucency and hardness (r = 0.335, P = 0.012), and a negative correlation between fracture toughness and all parameters other than shrinkage (translucency: r = -0.693/P < 0.001, flexural strength: r = -0.258/P = 0.046, hardness: r = -0.457/P < 0.001). Heating rate and final temperature should be considered while fabricating veneered zirconia restorations with tested ceramic as they affected the translucency, hardness, and fracture toughness.

8 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
ACAndrea Coldea
Andrea Coldea
JMJohn Meinen
John Meinen
MHMoritz Hoffmann
Moritz Hoffmann
AEAdham Elsayed
Adham Elsayed
Bogna StawarczykBogna Stawarczyk
Bogna Stawarczyk
To investigate the sintering shrinkage behavior of multigeneration, multilayer zirconia materials using geometrical measurements. Seven zirconia CAD/CAM materials were analyzed, comprising two mono-generation zirconia (HTML: Katana Zr, HTML Plus, 3Y-TZP; UTML: Katana Zr, UTML, 5Y-TZP) and five strength-gradient multilayer zirconia (AIDI: optimill 3D PRO Zir; PRIT: Priti multidisc ZrO2 multicolor; UPCE: Explore Esthetic; ZCPC: IPS e.max ZirCAD Prime; ZYML: Katana YML) materials. Cubes (10 × 10 × 10 mm3) were milled in varying positions within the disks. Geometrical measurements were applied before and after dense sintering using a micrometer screw gauge, light microscopy, as well as surface scans and shrinkages were calculated. Data were analyzed using Kolmogorov–Smirnov, five-way ANOVA followed by the Scheffé post hoc test, and partial eta squared, as well as the Kruskal–Wallis test, including Bonferroni correction (p < 0.05). The highest influence on the shrinkage was exerted by the zirconia material (ηP2 = 0.893, p < 0.001), followed by the test method (ηP2 = 0.175, p < 0.001), while the vertical and horizontal position and measurement point showed no impact on the shrinkage results (p = 0.195–0.763) in the global analysis. Depending on the test method, the pooled shrinkage values of all tested zirconia materials varied between 17.7 and 20.2% for micrometer screw gauge, 17.7 and 20.1% for light microscopy, and 17.8 and 21.1% for surface scan measurements. The shrinkage values measured in the upper, middle, and lower multilayered vertical direction did not differ significantly in the global analysis for the multilayer materials. Therefore, a uniform shrinkage of these strength-gradient multilayer zirconia materials within clinically relevant restorations can be assumed.