Shuai Hou

Shuai Hou

Auto-generated profile, based on publicly available information

Shuai Hou

CSG Electric Power Research Institute Co., Ltd

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2018 in Energies
Verified
Journal Article
Open access
PDF file
LYLin Yang
Lin Yang
WQWeihao Qiu
Weihao Qiu
JHJichao Huang
Jichao Huang
Yanpeng HaoYanpeng Hao
Yanpeng Hao
MFMingli Fu
Mingli Fu
LLLicheng Li
Licheng Li
In this paper, the calculation of the conductor temperature is related to the temperature sensor position in high-voltage power cables and four thermal circuits—based on the temperatures of insulation shield, the center of waterproof compound, the aluminum sheath, and the jacket surface are established to calculate the conductor temperature. To examine the effectiveness of conductor temperature calculations, simulation models based on flow characteristics of the air gap between the waterproof compound and the aluminum are built up, and thermocouples are placed at the four radial positions in a 110 kV cross-linked polyethylene (XLPE) insulated power cable to measure the temperatures of four positions. In measurements, six cases of current heating test under three laying environments, such as duct, water, and backfilled soil were carried out. Both errors of the conductor temperature calculation and the simulation based on the temperature of insulation shield were significantly smaller than others under all laying environments. It is the uncertainty of the thermal resistivity, together with the difference of the initial temperature of each radial position by the solar radiation, which led to the above results. The thermal capacitance of the air has little impact on errors. The thermal resistance of the air gap is the largest error source. Compromising the temperature-estimation accuracy and the insulation-damage risk, the waterproof compound is the recommended sensor position to improve the accuracy of conductor-temperature calculation. When the thermal resistances were calculated correctly, the aluminum sheath is also the recommended sensor position besides the waterproof compound.

22 December 2023 in Polymers
Verified
Journal Article
Open access
PDF file
YZYunpeng Zhan
Yunpeng Zhan
XYXu Yang
Xu Yang
Jiaming YangJiaming Yang
Jiaming Yang
SHShuai Hou
Shuai Hou
MFMingli Fu
Mingli Fu
To achieve exceptional recyclable DC cable insulation material using thermoplastic polypropylene (PP), we have introduced the organic polar molecule styrene-maleic anhydride copolymer (SMA) into PP-based insulation materials following the principles of deep trap modification. PP, PP/SMA, PP/ethylene-octene copolymer (POE), and PP/POE/SMA insulating samples were prepared, and their meso-morphology, crystalline morphology, and molecular structure were comprehensively characterized. The results indicate that SMA can be uniformly dispersed in PP with minimal impact on the crystalline morphology of PP. The DC electrical properties of the materials were tested at temperatures of 30, 50, and 70 °C. The findings demonstrate that the introduction of SMA can improve the DC properties of the material in both PP and PP/POE. The thermal stimulated depolarization current results reveal that SMA can introduce deep traps into the material, thereby improving its DC properties, which is in agreement with the quantum chemical calculation results. Subsequently, a bipolar carrier transport model was employed for coaxial cables to simulate the space charge distribution in the insulation layer of the four sets of insulation samples as well as the actual cable in service. The results highlight that SMA can significantly suppress space charge in PP and PP/POE systems, and it exhibits excellent electric field distortion resistance. In summary, the results illustrate that SMA is expected to be used as an organic deep trap modifier in PP-based cable insulation materials.

10 October 2025 in Energies
Verified
Journal Article
Open access
PDF file
WZWenbo Zhu
Wenbo Zhu
BHBaojun Hui
Baojun Hui
JLJianda Li
Jianda Li
THTao Han
Tao Han
LZLinjie Zhao
Linjie Zhao
SHShuai Hou
Shuai Hou
At present, the development of power cables shows three notable trends: higher voltage, longer distance and more complex environments. Against this backdrop, the limitations of traditional detection techniques in locating local defects have become increasingly apparent. Frequency Domain Reflectometry (FDR) has garnered sustained research attention both domestically and internationally due to its high sensitivity and accuracy in detecting localized defects. This paper aims to compare the defect localization effectiveness of the Fast Fourier Transform (FFT) method and the Inverse Fast Fourier Transform (IFFT) method within FDR. First, the differences between the two methods are analyzed from a theoretical perspective. Then, field tests are conducted on cables of varying voltage levels and lengths, with comparisons made using parameters such as full width at half maximum (FWHM) and signal-to-noise ratio (SNR). The results indicate that the FFT method is more suitable for low-interference or short cables, while the IFFT method is more suitable for high-noise, high-resolution, or long cables.

1 April 2026
Verified
Book Chapter
Closed access
PDF file
SHShuai Hou
Shuai Hou
YZYun-Peng Zhan
Yun-Peng Zhan
LJLei Jia
Lei Jia
MFMing-Li Fu
Ming-Li Fu
YLYan-Fei Li
Yan-Fei Li
LFLing-Meng Fan
Ling-Meng Fan

9 January 2026
Verified
Book Chapter
Closed access
PDF file
ZLZiyu Liu
Ziyu Liu
YZYunpeng Zhan
Yunpeng Zhan
MLMao Li
Mao Li
LLLiyong Lai
Liyong Lai
TXTao Xu
Tao Xu
SHShuai Hou
Shuai Hou

6 January 2026
Verified
Book Chapter
Closed access
PDF file
SHShuai Hou
Shuai Hou
YZYun-Peng Zhan
Yun-Peng Zhan
BHBao-Jun Hui
Bao-Jun Hui
MFMing-Li Fu
Ming-Li Fu
YLYan-Fei Li
Yan-Fei Li
LFLing-Meng Fan
Ling-Meng Fan