Microcirculatory obstruction is a hallmark of severe malaria, but mechanisms of parasite sequestration are only partially understood. Here, we developed a robust three-dimensional microvessel model that mimics the arteriole-capillary-venule (ACV) transition consisting of a narrow 5- to 10-μm-diameter capillary region flanked by arteriole- or venule-sized vessels. Using this platform, we investigated red blood cell (RBC) transit at the single cell and at physiological hematocrits. We showed normal RBCs deformed via in vivo–like stretching and tumbling with negligible interactions with the vessel wall. By comparison, Plasmodium falciparum–infected RBCs exhibited virtually no deformation and rapidly accumulated in the capillary-sized region. Comparison of wild-type parasites to those lacking either cytoadhesion ligands or membrane-stiffening knobs showed highly distinctive spatial and temporal kinetics of accumulation, linked to velocity transition in ACVs. Our findings shed light on mechanisms of microcirculatory obstruction in malaria and establish a new platform to study hematologic and microvascular diseases.
Falloposcopy is the endoscopic examination of the fallopian tubes, which are challenging to access due to their deep body location, small opening from the uterus, and lumen filled with plicae. We and others have developed endoscopes that are inserted through the uterus guided by a hysteroscope into the tubal ostium. To better understand how to utilize these endoscopes either as standalone devices or in concert with everting delivery balloons, a preliminary study of anatomy and mechanical behavior was performed ex vivo on porcine and human fallopian tubes. Segments of fallopian tubes from the isthmus, ampulla and infundibulum were inflated with saline either to bursting or held at sub-burst pressures with saline or a saline-filled balloon. Formalin fixed, paraffin embedded tissue sections stained with Masson’s trichrome were examined for damage to the mucosa and muscularis. Porcine fallopian tubes tolerated saline pressurization at 15 psi for 1 minute without morphological damage. Balloon inflation to 15 psi caused no apparent damage to the muscle layer or rupture of the fallopian tube, but balloon movement within the tube can denude the mucosal epithelial layer. Human fallopian tubes averaged higher burst pressure values than porcine tubes. Under pressurization, the external tube diameter expanded by minimal to moderate amounts. Human and porcine tissues were similar in histological appearance. These studies suggest that moderate pressurization is acceptable but will not appreciably expand the fallopian tube diameter. The results also indicate that pigs are a reasonable model to study damage from falloscopy as seen in human tissue.
We have developed endoscopes for the fallopian tubes that contain multispectral fluorescence imaging, optical coherence tomography, and/or cell collecting wires. The ability to expand the lumen of the fallopian tube with saline or balloon pressure has been proposed as a method for assuring high quality imaging and increasing the lumen diameter. Using ex vivo porcine and human tissue, we found that fallopian tubes can tolerate pressurization of up to 15 psi. Movement of balloons within the fallopian tube can denude the epithelial layer. The external diameter of tubes expanded by a minimal amount under pressurization, indicating sub-mm diameter endoscopes are required.