1 March 2017 in Journal of Biomedical Optics
A miniature wide-field multispectral endoscopic imaging system was developed enabling reflectance and fluorescence imaging over a broad wavelength range. At 0.8-mm diameter, the endoscope can be utilized for natural orifice imaging in small lumens such as the fallopian tubes. Five lasers from 250 to 642 nm are coupled into a diameter multimode fiber and transmitted to the endoscope distal tip for illumination. Ultraviolet and blue wavelengths excite endogenous fluorophores, which can provide differential fluorescence emission images for health and disease. Visible wavelengths provide reflectance images that can be combined for pseudo-white-light imaging and navigation. Imaging is performed by a diameter three-element lens system connected to a 3000-element fiber. The lens system was designed for a 70-deg full field of view, working distance from 3 mm to infinity, and 40% contrast at the Nyquist cutoff of the fiber bundle. Measured performance characteristics are near design goals. The endoscope was utilized to obtain example monochromatic, pseudo-white-light, and composite fluorescence images of phantoms and porcine reproductive tract. This work shows the feasibility of packaging a highly capable multispectral fluorescence imaging system into a miniature endoscopic system that may have applications in early detection of cancer.
9 September 2021 in Journal of Histotechnology
JDJoceline Dominguez-Cooks
+1
Falloposcopy is the endoscopic examination of the fallopian tubes, which are challenging to access due to their deep body location, small opening from the uterus, and lumen filled with plicae. We and others have developed endoscopes that are inserted through the uterus guided by a hysteroscope into the tubal ostium. To better understand how to utilize these endoscopes either as standalone devices or in concert with everting delivery balloons, a preliminary study of anatomy and mechanical behavior was performed ex vivo on porcine and human fallopian tubes. Segments of fallopian tubes from the isthmus, ampulla and infundibulum were inflated with saline either to bursting or held at sub-burst pressures with saline or a saline-filled balloon. Formalin fixed, paraffin embedded tissue sections stained with Masson’s trichrome were examined for damage to the mucosa and muscularis. Porcine fallopian tubes tolerated saline pressurization at 15 psi for 1 minute without morphological damage. Balloon inflation to 15 psi caused no apparent damage to the muscle layer or rupture of the fallopian tube, but balloon movement within the tube can denude the mucosal epithelial layer. Human fallopian tubes averaged higher burst pressure values than porcine tubes. Under pressurization, the external tube diameter expanded by minimal to moderate amounts. Human and porcine tissues were similar in histological appearance. These studies suggest that moderate pressurization is acceptable but will not appreciably expand the fallopian tube diameter. The results also indicate that pigs are a reasonable model to study damage from falloscopy as seen in human tissue.