Composites such as carbon fiber are used extensively by automotive, aerospace, marine, and energy industries due to their strong mechanical properties. However, there are still many areas it is lacking in testing, especially related to its electrophoretic deposition. In this research work, the tensile strength and Young’s modulus of CNT–CF/epoxy composites were measured using the tensile test by varying the electrophoretic deposition (EPD) process parameters. Response surface methodology (RSM) was used to optimize the three main parameters in this EPD process: the volume ratio (water as the basis), deposition voltage, and time to obtain the maximum tensile properties of the composites. There were four volume ratios (0%, 20%, 80% and 100%) used in this design of experiment (DoE) with ratios’ pairs of 0%, 100%, and 20%, 80%. For this study, water and methanol were used as the suspension medium. This design’s deposition voltage and time were 10 to 20 V and 5 to 15 min. ANOVA further verified the responses’ adequacy. The optimum conditions for the first Design of Experiment (DoE) (0% and 100%) were identified as a volume ratio of 99.99% water, deposition voltage of 10 V, and 12.14 min. These conditions provided the maximum strength of these composites with a tensile strength of 7.41 N/mm2 and Young’s modulus of 279.9 N/mm2. Subsequently, for the second DoE (20% and 80%), tensile strength of 7.28 N/mm2 and Young’s modulus of 274.1 N/mm2 were achieved with the ideal conditions: volume ratio of 44.80% water, deposition voltage of 10.04 V, and time of 6.89 min. It can be concluded that the ideal interaction between these three EPD parameters was necessary to achieve composites with good tensile properties.
The Micro gas turbine plant (MGTP) is used for the decentralized supply to the external electric power consumers. Its nominal and heat capacity are 100kW and 200kW respectively. Its critical part is a rotor with the operating speed of 65,000rpm. It consists of two subsystems: a turbocharger rotor (TCR) and a rotor of the starter-generator (SGR) connected by elastic coupling. One of the design requirements for the rotor is the absence of critical speed in the ± 30% operating speed range.In this article the natural and the critical frequencies of the rotor are analyzed.Its natural frequencies evaluated for the whole rotor system and for each of the two subsystems individually. For the TCR such an assessment was obtained through the finite element method (FEM) calculation. Due to the complexity of the SGR design, its natural frequencies were estimated and proved experimentally using LMS modal analysis technology. Also a study of the influence of bearings stiffness on the natural frequencies of the rotor was conducted to identify its acceptable range.The study of the critical speeds of the MGTP rotor was performed in two stages by calculation: an analytical and numerical solution of the test problem obtained firstly in order to confirm the accuracy of FEM calculation in the Ansys Workbench package followed by the critical speeds evaluated through the FEM calculation on solid 3D model.Based on the obtained results, some recommendations on the design of the rotor elements are given to ensure the natural frequencies are in the restrained region
The paper describes the calculated and experimental determination of the oscillation modes of a Coriolis flowmeter. To define the estimated parametric oscillation modes, we formed a model of the volumetric flowmeter finite element. The model allows the evaluation of the impact of changes in the meter size and the medium density on the flowmeter frequency. The results of the calculations of the finite element model were verified by modal tests of the flowmeter