Kazuhisa Matsumoto

Dr. Kazuhisa Matsumoto

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2023 in Journal of Arrhythmia
Verified
Journal Article
Open access
KMKazuhisa Matsumoto
Kazuhisa Matsumoto
DKDaisuke Kawano
Daisuke Kawano
WSWataru Sasaki
Wataru Sasaki
NTNaomichi Tanaka
Naomichi Tanaka
MNMasataka Narita
Masataka Narita
KMKazuo Matsumoto
Kazuo Matsumoto
Background: Recently, a novel contact force (CF) sensing catheter with mesh‐shaped irrigation tip (TactiFlex SE, Abbott) was invented and is expected to be useful for safe and effective radiofrequency ablation. However, this catheter's detailed characteristics of the lesion formation are unknown.Methods: With an in vitro model, TactiFlex SE and its predecessor, FlexAbility SE, were used. A cross‐sectional analysis of 60 s lesions (combination of various energy power settings [30, 40, and 50 W], and CFs [10, 30, and 50 g]) and longitudinal analysis (combination of various powers [40 or 50 W], CFs [10, 30, and 50 g] and ablation times [10, 20, 30, 40, 50, and 60 s]) of both catheters were analyzed and compared.Results: One hundred eighty RF lesions were created in protocol 1 and 300 in protocol 2. The lesion formation, impedance changes, and steam pops characteristics were similar between the two catheters. Higher CFs were related to higher incidences of steam pops. A nonlinear, time‐dependent increase in the lesion depth and diameter was observed for all power and CF settings, and linear, positive correlations between the RF delivery time and lesion volume were observed for all power settings. Compared with 40 W, a 50 W ablation created greater lesions. Longer durations with higher CF settings had a higher steam pop incidence.Conclusions: The lesion formation and incidence of steam pops with TactiFlex SE and FlexAbility SE were similar. A 40 or 50 W ablation with careful CF control not to exceed 30 g in addition to monitoring impedance drops was required to safely create transmural lesions.

1 November 2024 in EP Europace
Verified
Journal Article
Open access
RWRyuta Watanabe
Ryuta Watanabe
KNKoichi Nagashima
Koichi Nagashima
YSYasuhiro Shirai
Yasuhiro Shirai
TKTakayuki Kitai
Takayuki Kitai
TOTakuya Okada
Takuya Okada
YOYasuo Okumura
Yasuo Okumura
Aims: Catheter ablation (CA) of idiopathic ventricular arrhythmias (VAs) from the epicardial left ventricular summit is challenging. The endocardial approach targets two sites: the endocardial closest site (ECS) to the epicardial earliest activation site (epi-EAS) and the endocardial earliest activation site (endo-EAS). We aimed to differentiate between cases where CA at the ECS was effective and where CA at the endo-EAS yielded success. Methods and results: Fifty-eight patients (47 men; age 60 ± 13 years) were analysed with VAs in which the EAS was observed in the coronary venous system (CVS). Overall, VAs were successfully eliminated in 42 (72%) patients: 8 in the CVS, 8 where the ECS matched with the endo-EAS, 11 at the ECS, and 15 at the endo-EAS. A successful ECS ablation was associated with a shorter epi-EAS–ECS distance (10.2 ± 4.7 vs. 18.8 ± 5.3 mm; P < 0.001) and shorter epi-EAS–left main coronary trunk (LMT) ostial distance (20.3 ± 7.6 vs. 30.3 ± 8.4 mm; P = 0.005), with optimal cut-off values of ≤12.6 and ≤24.0 mm, respectively. A successful endo-EAS ablation was associated with an earlier electrogram at the endo-EAS [23 (8, 36) vs. 15 (0, 19) ms preceding the QRS; P < 0.001] and shorter epi-EAS–endo-EAS interval [6 (1, 8) vs. 22 (12, 25) ms; P < 0.001], with optimal cut-off values of ≥18 and ≤9 ms, respectively. Conclusion: Shorter anatomical distances between the epi-EAS and ECS, and between the epi-EAS and LMT ostium, predict a successful ECS ablation. The prematurity of the endo-EAS electrogram and a shorter interval between the epi-EAS and endo-EAS predicted a successful endo-EAS ablation.

1 June 2009
Verified
Journal Article
Closed access
HIHironori Inoue
Hironori Inoue
MUMasahiro Ueno
Masahiro Ueno
HYHiroyuki Yamamoto
Hiroyuki Yamamoto
KMKazuhisa Matsumoto
Kazuhisa Matsumoto
KTKoji Tao
Koji Tao
RSRyuzo Sakata
Ryuzo Sakata

1 October 2006 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Open access
PDF file
KMKazuhisa Matsumoto
Kazuhisa Matsumoto
ITIsao Tsuneyoshi
Isao Tsuneyoshi
YIYoshifumi Iguro
Yoshifumi Iguro
TKTamahiro Kinjo
Tamahiro Kinjo
GYGoichi Yotsumoto
Goichi Yotsumoto
RSRyuzo Sakata
Ryuzo Sakata
Objective: There are few data available on the effect of ultrasonic skeletonization with the harmonic scalpel on internal thoracic artery (ITA) and g

13 August 2024 in Journal of Arrhythmia
Verified
Journal Article
Open access
WSWataru Sasaki
Wataru Sasaki
NTNaomichi Tanaka
Naomichi Tanaka
KMKazuhisa Matsumoto
Kazuhisa Matsumoto
DKDaisuke Kawano
Daisuke Kawano
MNMasataka Narita
Masataka Narita
RKRitsushi Kato
Ritsushi Kato
Background: CARTONET® enables automatic ablation site classification and reconnection site prediction using machine learning. However, the accuracy of the site classification model and trends of the site prediction model for potential reconnection sites are uncertain.Methods: We studied a total of 396 cases. About 313 patients underwent pulmonary vein isolation (PVI), including a cavotricuspid isthmus (CTI) ablation (PVI group) and 83 underwent PVI and additional ablation (i.e., box isolation) (PVI+ group). We investigated the sensitivity and positive predictive value (PPV) for automatic site classification in the total cohort and compared these metrics for PV lesions versus non‐PV lesions. The distribution of potential reconnection sites and confidence level for each site was also investigated.Results: A total of 29,422 points were analyzed (PV lesions [n = 22 418], non‐PV lesions [n = 7004]). The sensitivity and PPV of the total cohort were 71.4% and 84.6%, respectively. The sensitivity and PPV of PV lesions were significantly higher than those of non‐PV lesions (PV lesions vs. non‐PV lesions, %; sensitivity, 75.3 vs. 67.5, p < .05; PPV, 91.2 vs. 67.9, p < .05). CTI and superior vena cava could not be recognized or analyzed. In the potential reconnection prediction model, the incidence of potential reconnections was highest in the posterior, while the confidence was the highest in the roof.Conclusion: The automatic site classification of the CARTONET®R12.1 model demonstrates relatively high accuracy in pulmonary veins excluding the carina. The prediction of potential reconnection sites feature tends to anticipate areas with poor catheter stability as reconnection sites.

13 March 2025 in Journal of Arrhythmia
Verified
Journal Article
Open access
MKMaiko Kuroda
Maiko Kuroda
MNMichio Nagashima
Michio Nagashima
MNMasataka Narita
Masataka Narita
WSWataru Sasaki
Wataru Sasaki
NTNaomichi Tanaka
Naomichi Tanaka
RKRitsushi Kato
Ritsushi Kato
Background: Technological development has improved the battery longevity of cardiac implantable electronic devices (CIEDs). However, there have been no reports on the extent of the improvement in battery longevity in the real world. Methods: Patients who underwent CIED exchanges from February 2006 to June 2023 were included in this study. The actual battery longevity calculated from the implantation date to the battery replacement date and the predicted battery longevity based on manufacturer reports were investigated. All patients were divided into five groups according to their initial implantation dates. After excluding the first and last groups, the data among the middle three groups (P1, P2, P3) were compared. Results: A total of 3119 patients (pacemakers [PMs], 2138; ICDs, 477; cardiac resynchronization therapy pacemakers [CRTPs], 121; cardiac resynchronization therapy defibrillators [CRTDs], 383) were enrolled in this study. The predicted device longevity improved over time for all devices, but in recent analyses, it has been overestimated compared to the actual device longevity for PMs, ICDs, and CRTPs. The actual device longevity of PMs, ICDs, and CRTDs exhibited an extension in the early two periods (P1 vs. P2), but no extension was observed in the most recent two periods (P2 vs. P3). CRTPs showed no improvement in any of the periods. Conclusion: The battery longevity has improved by only about 1 year over the past nearly 15 years. Moreover, the discrepancy between the predicted and actual battery longevity suggests that a reevaluation of the methods for calculating the predicted battery longevity may be necessary.