Daisuke Kawano

Daisuke Kawano

Auto-generated profile, based on publicly available information

Daisuke Kawano

Department of Cardiology Saitama Medical University International Medical Center Hidaka Saitama Japan

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2023 in Journal of Arrhythmia
Verified
Journal Article
Open access
KMKazuhisa Matsumoto
Kazuhisa Matsumoto
DKDaisuke Kawano
Daisuke Kawano
WSWataru Sasaki
Wataru Sasaki
NTNaomichi Tanaka
Naomichi Tanaka
MNMasataka Narita
Masataka Narita
KMKazuo Matsumoto
Kazuo Matsumoto
Background: Recently, a novel contact force (CF) sensing catheter with mesh‐shaped irrigation tip (TactiFlex SE, Abbott) was invented and is expected to be useful for safe and effective radiofrequency ablation. However, this catheter's detailed characteristics of the lesion formation are unknown.Methods: With an in vitro model, TactiFlex SE and its predecessor, FlexAbility SE, were used. A cross‐sectional analysis of 60 s lesions (combination of various energy power settings [30, 40, and 50 W], and CFs [10, 30, and 50 g]) and longitudinal analysis (combination of various powers [40 or 50 W], CFs [10, 30, and 50 g] and ablation times [10, 20, 30, 40, 50, and 60 s]) of both catheters were analyzed and compared.Results: One hundred eighty RF lesions were created in protocol 1 and 300 in protocol 2. The lesion formation, impedance changes, and steam pops characteristics were similar between the two catheters. Higher CFs were related to higher incidences of steam pops. A nonlinear, time‐dependent increase in the lesion depth and diameter was observed for all power and CF settings, and linear, positive correlations between the RF delivery time and lesion volume were observed for all power settings. Compared with 40 W, a 50 W ablation created greater lesions. Longer durations with higher CF settings had a higher steam pop incidence.Conclusions: The lesion formation and incidence of steam pops with TactiFlex SE and FlexAbility SE were similar. A 40 or 50 W ablation with careful CF control not to exceed 30 g in addition to monitoring impedance drops was required to safely create transmural lesions.

29 June 2021 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
DKDaisuke Kawano
Daisuke Kawano
HMHitoshi Mori
Hitoshi Mori
RKRitsushi Kato
Ritsushi Kato
KTKenta Tsutsui
Kenta Tsutsui
YIYoshifumi Ikeda
Yoshifumi Ikeda
KMKazuo Matsumoto
Kazuo Matsumoto

20 November 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
HFHidehira Fukaya
Hidehira Fukaya
HMHitoshi Mori
Hitoshi Mori
JOJun Oikawa
Jun Oikawa
DKDaisuke Kawano
Daisuke Kawano
HNHironori Nakamura
Hironori Nakamura
SFSeiji Fukamizu
Seiji Fukamizu

5 May 2021 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
HMHitoshi Mori
Hitoshi Mori
DKDaisuke Kawano
Daisuke Kawano
NSNaokata Sumitomo
Naokata Sumitomo
SMShota Muraji
Shota Muraji
TNTaisuke Nabeshima
Taisuke Nabeshima
KMKazuo Matsumoto
Kazuo Matsumoto

13 October 2022 in Journal of Arrhythmia
Verified
Journal Article
Open access
DKDaisuke Kawano
Daisuke Kawano
HMHitoshi Mori
Hitoshi Mori
KTKenta Tsutsui
Kenta Tsutsui
HFHidehira Fukaya
Hidehira Fukaya
NTNaomichi Tanaka
Naomichi Tanaka
RKRitsushi Kato
Ritsushi Kato
Background: The local impedance (LI) is an emerging technology that monitors tissue‐catheter coupling during radiofrequency (RF) ablation. The relationships between the LI, RF delivery time, and lesion formation remain unclear.Methods: Using an LI‐enabled RF catheter in an ex vivo experimental model, RF lesions were created combined with various steps in the power (40 and 50 W), CF (10 g, 30 g, and 50 g), and time (10s, 20s, 30s, 40s, 50s, and 60s at 40 W and 5 s, 10s, 20s, 30s, 40s, 50s, and 60s at 50 W). The correlations between the LI drop, lesion size, and RF delivery time were evaluated. The rate of change in the time‐dependent gain in the LI, depth, and diameter and the time to reach 90% decay of the peak dY/dT (time to 90% decay) were assessed.Results: The correlation between the LI drop and ablation time revealed non‐linear changes. The time to a 90% decay in the LI drop differed depending on the RF ablation setting and was always shorter with the 50 W setting than 40 W setting. The LI drop always correlated with the lesion formation under all ablation power settings. Deeper or wider lesions were predominantly created within the time to 90% decay of the LI drop.Conclusion: The LI drop was useful for predicting lesion sizes. Deeper or wider lesions cannot be obtained with a longer ablation than the 90% decay time of the LI drop. A shorter ablation than the 90% decay time of the LI drop would be preferable for an effective ablation.

29 December 2023 in Journal of Arrhythmia
Verified
Journal Article
Open access
HMHitoshi Mori
Hitoshi Mori
AHAkira Hamabe
Akira Hamabe
DKDaisuke Kawano
Daisuke Kawano
TNTsukasa Naganuma
Tsukasa Naganuma
MTMai Tahara
Mai Tahara
RKRitsushi Kato
Ritsushi Kato
Background: The role of the pulmonary veins (PVs) as triggers in atrial fibrillation (AF) is well‐known; however, their detailed electrophysiological properties have not been thoroughly examined.Objective: This study aimed to investigate the electrophysiological properties of the PVs between paroxysmal AF (pAF) and persistent AF (perAF).Methods: Prior to catheter ablation in patients with pAF (n = 51) and perAF (n = 41), a voltage map of the left atrium and PVs was created under sinus rhythm, and the area of the myocardial sleeves in the PVs and their electrophysiological characteristics, including the pacing threshold and effective refractory period (ERP), were compared between the two groups.Results: Compared with perAF, the myocardial sleeves of PVs for pAF were significantly larger for all PVs. The ERP for perAF was significantly shorter than that for pAF for all PVs. The pacing threshold for perAF was significantly higher than that for pAF for the right and left superior PVs.Conclusion: In patients with perAF, a decrease in the normal myocardial sleeves and a shortening of the ERP were observed for all PVs. Those changes in the electrophysiological properties of the PVs might be related to the persistence of AF.