Mario Lima

Mr. Mario Lima

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JRJacklyn D. Reis
Jacklyn D. Reis
ASAli Shahpari
Ali Shahpari
RFRicardo Ferreira
Ricardo Ferreira
SZSomayeh Ziaie
Somayeh Ziaie
DNDarlene M. Neves
Darlene M. Neves
António TeixeiraAntónio Teixeira
António Teixeira
In this paper, we numerically and experimentally demonstrate a bidirectional Terabit+ ultradense wavelength-division multiplexing (UDWDM) coherent passive optical network with Nyquist shaped 16-ary quadrature amplitude modulation, offering up to 10 Gb/s service capabilities per user/wavelength in a total spectrum of 12.8 nm over 40 km of standard single-mode fiber. This paper first demonstrates the capability of Nyquist pulse shaping to mitigate crosstalk arising from back-reflections and nonlinear effects in UDWDM networks with coherent transceivers. The latter part of the paper experimentally investigates the bidirectional transmission in terms of receiver sensitivity and nonlinear tolerance under different network transmission capacity conditions, e.g., number of users and bit rate per users.

12 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ABAna Bastos
Ana Bastos
Carlos VicenteCarlos Vicente
Carlos Vicente
Rui Oliveira-SilvaRui Oliveira-Silva
Rui Oliveira-Silva
NSNuno Joao Silva
Nuno Joao Silva
MTMarta Tacão
Marta Tacão
Rute FerreiraRute Ferreira
Rute Ferreira
The development of portable low-cost integrated optics-based biosensors for photonics-on-a-chip devices for real-time diagnosis are of great interest, offering significant advantages over current analytical methods. We report the fabrication and characterization of an optical sensor based on a Mach-Zehnder interferometer to monitor the growing concentration of bacteria in a liquid medium. The device pattern was imprinted on transparent self-patternable organic-inorganic di-ureasil hybrid films by direct UV-laser, reducing the complexity and cost production compared with lithographic techniques or three-dimensional (3D) patterning using femtosecond lasers. The sensor performance was evaluated using, as an illustrative example, E. coli cell growth in an aqueous medium. The measured sensitivity (2 × 10−4 RIU) and limit of detection (LOD = 2 × 10−4) are among the best values known for low-refractive index contrast sensors. Furthermore, the di-ureasil hybrid used to produce this biosensor has additional advantages, such as mechanical flexibility, thermal stability, and low insertion losses due to fiber-device refractive index mismatch (~1.49). Therefore, the proposed sensor constitutes a direct, compact, fast, and cost-effective solution for monitoring the concentration of lived-cells.

21 March 2003 in Journal of Optics A: Pure and Applied Optics
Verified
Journal Article
Closed access
Orlando FrazãoOrlando Frazão
Orlando Frazão
MLMario Lima
Mario Lima
JSJosé Luís Santos
José Luís Santos

22 October 2018 in ACS Omega
Verified
Journal Article
Open access
ABAna Bastos
Ana Bastos
BMBarry McKenna
Barry McKenna
MLMario Lima
Mario Lima
PAPaulo S. André
Paulo S. André
Luís CarlosLuís Carlos
Luís Carlos
Rute FerreiraRute Ferreira
Rute Ferreira
Visible-light communications (VLCs) based on white light-emitting diodes (LEDs) are emerging as a low-cost and energy-efficient alternative solution to wireless communications. As white emitting LEDs use a combination of a long-lived yellow emission combined with the faster response of a blue emitting LED (∼460 nm), VLC technology requires amplification of the blue component to improve the signal-to-noise ratio. We report the fabrication and characterization of planar and channel waveguides based on a blue-emitting polyfluorene conjugated polyelectrolyte, namely, poly[9,9-bis(4-sulfonylbutoxyphenyl)fluorene-2,7-diyl-alt-1,4-phenylene] (PBS-PFP) incorporated into diureasil organic–inorganic hybrids for optical amplification in VLC. Taking advantage of the diureasil host as a UV self-patternable material, direct UV laser writing was used to pattern channel waveguides with a larger refractive index (Δn=0.09) compared to the nonexposed region, enabling confinement and guidance of the PBS-PFP emission with a maximum optical gain efficiency value of 1.62 ± 0.02 cm μJ–1. This value is among the best figures of merit known for polymeric materials with additional advantages added by the diureasil hybrid host, namely, mechanical flexibility, thermal stability, and low insertion losses due to the nearly null refractive index contrast between the optical fiber and the amplification device, establishing the proposed approach as a promising cost-effective solution for optical amplification in VLCs.

23 June 2022 in IEEE Access
Verified
Journal Article
Open access
CTCátia Tavares
Cátia Tavares
JSJoao Oliveira E. Silva
Joao Oliveira E. Silva
AMAndre Mendes
Andre Mendes
LRLeonor Rebolo
Leonor Rebolo
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
Paulo AntunesPaulo Antunes
Paulo Antunes
People spend more and more time sitting and this habit has been shown to cause spine pathologies. Thus, the scientific community and the industry have become interested in instrumented chairs development to detect incorrect user postures. In this work we present the development and implementation of invisibles and non-intrusive plastic optical fiber sensor cells to monitor the posture and evaluate the ergonomic behavior of a seated person. The low-cost plastic optical fiber (POF) based sensing devices developed in this work, were implemented in an office chair, to evaluate the workers posture throughout their work day. In addition to the sensors, Android and PC software applications were developed, to provide real time feedback and alerts to the user whenever an inadequate posture is detected, or the seating position is the same for a long time. The proposed approach was evaluated in a study involving six users, and results show that it can detect the user’s position with 96.6% accuracy.

15 May 2023 in IEEE Access
Verified
Journal Article
Open access
CTCátia Tavares
Cátia Tavares
JSJoão Oliveira E. Silva
João Oliveira E. Silva
AMAndré Mendes
André Mendes
LRLeonor Rebolo
Leonor Rebolo
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
Paulo AntunesPaulo Antunes
Paulo Antunes
There is a growing tendency for people to spend more and more hours of their day sitting. This position leads to an increase in the postural problems in the population. For workers who have to spend long hours at work, in a seated position, investment should be directed towards the development of equipment that improves their working conditions, such as smart instrumented chairs with warnings of changes in position. With this work we propose a standard office chair instrumentation approach, designed to allow monitoring physiological parameters such as: posture of the seated person (user); body temperature; and respiratory frequency. The system also allows monitoring environmental parameters such as: temperature; relative humidity; atmospheric concentration of carbon dioxide (CO 2 ); noise; and light levels. The chair enables the interaction with control equipment to adjust the comfort level, advising the need for rest time, repositioning notifications, and the real time visualization of data, using applications for Windows and Android. The system was tested by six users and evaluated in the detection of six different postures for each user, while sitting on the chair, presenting an 100% accuracy on the posture detection and a maximum of 18% error on the physiological parameters sensing. Experimental results show the adequate functionality of the instrumented chair, which could contribute to the prevention of pathologies associated with improper posture and the improvement of work productivity.