Wietske Verveld

Mrs. Wietske Verveld

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2024 in Food Research International
Verified
Journal Article
Open access
WVWietske Verveld
Wietske Verveld
JWJohanna Rebecca de Wolf
Johanna Rebecca de Wolf
CLChris Legtenberg
Chris Legtenberg
TKTom Knop
Tom Knop
NBNienke Bosschaart
Nienke Bosschaart
Milk fat globules (MFGs) in human milk provide energy to breastfed infants and support infant development. Accurate measurements of MFG size distributions are important to better understand MFG function and origin, as well as the influence of MFG size on milk composition analysis methods. Nevertheless, commonly used laser diffraction systems have never been thoroughly validated for size distribution measurements in human milk. Here, we introduce a new method for determining the size distribution of milk fat globules in human milk, using 3D confocal laser scanning microscopy (CLSM) in combination with fluorescent labeling of MFGs. We validate and compare 3D CLSM to laser diffraction (Mastersizer 2000, Malvern Panalytical), using polystyrene microsphere size standards. Next, we apply both methods to evaluate MFG size distributions in human milk. We show that 3D CLSM can be used to obtain more accurate size distributions between 500 nm and 10 μm compared to laser diffraction. Importantly, MFG size distributions obtained with 3D CLSM contain no secondary population around 1 μm, in contrast to laser diffraction measurements. This suggests that the bimodal MFG distribution obtained by laser diffraction can be an artifact of the built-in fitting algorithm, instead of an actual feature of human milk. This work demonstrates that care should be taken when interpreting size distributions of MFGs measured with laser diffraction and that 3D CLSM is an accurate alternative for measuring size distributions in lactation and dairy research.

20 December 2024 in Foods
Verified
Journal Article
Open access
PDF file
JWJohanna Rebecca de Wolf
Johanna Rebecca de Wolf
KAKawthar Ali
Kawthar Ali
CLChris Legtenberg
Chris Legtenberg
WVWietske Verveld
Wietske Verveld
NBNienke Bosschaart
Nienke Bosschaart
The refractive index (RI) of human milk serum (also known as whey, milk soluble fraction or milk plasma) depends on the individual molecular species dissolved in the serum and their concentrations. Although the human milk serum RI is known to influence milk analysis methods based on light scattering, the RI dependency on human milk serum composition is currently unknown. Therefore, we systematically evaluate how the RI depends on natural variations in macronutrient concentrations in the soluble fraction. We measure RI variations in serum simulating samples with controlled macronutrient concentrations, as well as skimmed and whole fore-, bulk, and hindmilk from 19 donors. For both types of samples, we relate the measured RI to the macronutrient composition. From the serum simulating samples, we observe that the RI depends more on variations in whey protein, than carbohydrate concentrations, while minerals have negligible influence. For all donated samples, the average RI was 1.3470 (range 1.3466–1.3474). Per donor, no significant differences were observed in RI between fore-, bulk, and hindmilk. We conclude that protein and solids-not-fat (i.e., the total contribution of carbohydrates, proteins and minerals present in milk) concentrations are most predictive for human milk serum RI.

29 November 2025 in Journal of Human Lactation
Verified
Journal Article
Open access
WVWietske Verveld
Wietske Verveld
JWJohanna Rebecca de Wolf
Johanna Rebecca de Wolf
CLChris Legtenberg
Chris Legtenberg
NBNienke Bosschaart
Nienke Bosschaart
Background: Human milk sub-sampling protocols are used in lactation research to estimate milk composition, while minimizing interference with normal breastfeeding. However, macronutrient concentrations in human milk can be highly variable, and the accuracy of sub-sampling protocols for a single breastfeed is currently unknown. Aim: We investigated the accuracy of three milk sub-sampling protocols for estimating the macronutrient concentrations of a complete feed: the mean of pre- and post-feed samples, pre-feed samples only, and post-feed samples only. Method: In this observational study, macronutrient concentrations from each sub-sampling protocol were compared to the volume-weighted average of the complete pumping session, based on foremilk, bulk milk, and hindmilk samples from 15 mothers. Macronutrient concentrations of each milk fraction were measured with a human milk analyzer. Additionally, correlations between macronutrient concentrations and lactation characteristics were studied. Results: Macronutrient concentrations from each sub-sampling protocol were strongly correlated with the volume-weighted average reference concentrations. Significant biases were found for the fat concentration (between -1.3 and +1.9 g/dl, depending on the protocol), but not for protein and carbohydrate concentrations. Conclusions: For the fat concentration, none of the three sub-sampling protocols was accurate. The mean of pre- and post-feed samples could, however, be used for high-fat milk samples where measurement errors exceed the bias (+0.3 g/dl). Pre-feed or post-feed samples only should not be used to estimate the fat concentration of a complete feed. For proteins and carbohydrates, one milk sample taken at any moment in a breastfeed is sufficient to represent the concentration in the complete feed.

1 August 2025 in Journal of Biomedical Optics
Verified
Journal Article
Open access
DTDavid Thompson
David Thompson
WVWietske Verveld
Wietske Verveld
GLGuillaume Lajoinie
Guillaume Lajoinie
MVMichel Versluis
Michel Versluis
WSWiendelt Steenbergen
Wiendelt Steenbergen
NBNienke Bosschaart
Nienke Bosschaart
SignificanceMonte Carlo simulation of light propagation in turbid media is important in biomedical optics. Most existing platforms simulate light-tissue interactions in backscattering and planar geometries and are voxel-based, which limits their ability to model curved boundaries accurately. Few platforms incorporate Doppler shifts from flowing media, and they allow limited customization of flow profiles and scattering properties. Although laser Doppler flowmetry (LDF) is common in backscattering-based tissue measurements or low-scattering through-transmission setups, the intermediate case of through-transmission measurements in more scattering samples is underexplored. This case is relevant for applications such as flow quantification in lab-on-a-chip systems and inline flow sensors for biological fluids.AimTo study flow in highly scattering samples (1 to 10 mm−1), we developed a voxel-free Monte Carlo simulation platform for through-transmission LDF: MC-Doppler. We compare simulated and experimental Doppler power spectra.ApproachMC-Doppler uses unit vectors and ray tracing to model light propagation, with fully customizable scattering phase functions and flow fields. It was tested with various suspensions of differently sized polystyrene beads, at flow rates ranging from 0 to 15 mL/min, within a 1 mm diameter glass tube.ResultsSimulated and measured Doppler power spectra matched well for scattering coefficients up to 5 mm−1. Mismatches between the spectra were found near 10 mm−1.ConclusionsMC-Doppler accurately simulates light propagation for through-transmission laser Doppler up to moderate scattering coefficients.

1 January 2025
Verified
Conference Paper
Closed access
PDF file
WVWietske Verveld
Wietske Verveld
JWJohanna R. de Wolf
Johanna R. de Wolf
WPWilma Petersen
Wilma Petersen
NBNienke Bosschaart
Nienke Bosschaart
Human milk fat measurements are crucial for lactation care and research. We present the potential of angular light scattering for fat content quantification, based on goniometric measurements and fat globule sizes of fifty milk samples.

1 January 2026 in Biophotonics Discovery
Verified
Journal Article
Open access
WVWietske Verveld
Wietske Verveld
JWJohanna Rebecca de Wolf
Johanna Rebecca de Wolf
NBNienke Bosschaart
Nienke Bosschaart
SignificanceDespite the numerous benefits of breastfeeding, many mothers quit breastfeeding early due to understudied lactation problems. Optical and photonic techniques provide promising, objective, and non-invasive methods for human milk analysis but require accurate characterization and modeling of light scattering in human milk.AimWe aimed to describe the influences of sample-specific properties on the forward scattering coefficient of human milk samples.ApproachWe composed an experimental dataset of 50 human milk samples, containing the scattering coefficient, fat concentration, serum refractive index, milk fat globule (MFG) refractive index, MFG size distribution, and refractive index and size distribution of non-fat particles per sample. We reconstructed scattering coefficients using Mie theory with sample-specific properties and compared them to experimental values.ResultsThis study confirmed a moderate correlation between experimental and reconstructed scattering coefficients when only the sample-specific fat concentration was considered (Spearman ρ=0.62). Including the sample-specific MFG size distribution significantly improved the correlation (ρ=0.82), while the sample-specific scattering contribution of non-fat particles and refractive index of serum and MFGs had a negligible influence.ConclusionsThe sample-specific fat concentration and MFG size distribution are the most important parameters to consider when developing light scattering models of human milk.