5 August 2024 in IEEE Transactions on Biomedical Engineering
Background : Handheld laser speckle contrast imaging (LSCI) is crucial in clinical settings, but motion artifacts (MA) can compromise perfusion image reliability. Current prevention and suppression methods are often impractical or complex. Machine vision techniques, promising in medical imaging, could improve signal quality, but their use in suppressing MA is still unexplored. Objective : We propose an innovative method based on linear regression for MA correction (MAC) in LSCI and validate it in vivo. Methods : We performed paired handheld and mounted LSCI measurements on 14 subjects with psoriasis using the previously validated handheld perfusion imager (HAPI). By marking lesion boundaries for clinical purposes, the HAPI used a monochromatic camera for both speckle imaging and motion detection, simplifying hardware requirements. Accurate estimation of relative displacements between the test object and LSCI probe allowed us to apply MAC to the perfusion images. Results : Local perfusion values correlated with applied speed were used to calculate and correct MA. The difference between mean perfusion in handheld and mounted modes after MAC significantly decreased (median error 14.2 perfusion units (p.u.) on lesions before correction ( $p< 0.0005$ ) and 0.5 p.u. after correction ( $p=0.2$ )). Conclusion : The findings provide evidence for robust handheld LSCI and validate the MA technique in psoriasis case. Of the two causes of MA-onsurface speeds and wavefront tilt-we address the former and correct mean perfusion, assuming constant temporal perfusion at each location. Significance : We describe a practical, non-contact, marker-free technique for reliable handheld perfusion imaging, supporting further clinical translation in plastic surgery and burns.
7 August 2023 in Biomedical Optics Express
We propose a new, user-friendly and accessible approach for fabricating thin phantoms with controllable absorption properties in magnitude, spectral shape, and spatial distribution. We utilize a standard office laser color printer to print on polyurethane thin films (40 – 60 μm), commonly available as medical film dressings and ultrasound probe covers. We demonstrate that the optical attenuation and absorption of the printed films correlate linearly with the printer input settings (opacity), which facilitates a systematic phantom design. The optical and acoustic properties of these polyurethane films are similar to biological tissue. We argue that these thin phantoms are applicable to a wide range of biomedical applications. Here, we introduce two potential applications: (1) homogeneous epidermal melanin phantoms and (2) spatially resolved absorbers for photoacoustic imaging. We characterize the thin phantoms in terms of optical properties, thickness, microscopic structure, and reproducibility of the printing process.
7 November 2024 in Food Research International
Milk fat globules (MFGs) in human milk provide energy to breastfed infants and support infant development. Accurate measurements of MFG size distributions are important to better understand MFG function and origin, as well as the influence of MFG size on milk composition analysis methods. Nevertheless, commonly used laser diffraction systems have never been thoroughly validated for size distribution measurements in human milk. Here, we introduce a new method for determining the size distribution of milk fat globules in human milk, using 3D confocal laser scanning microscopy (CLSM) in combination with fluorescent labeling of MFGs. We validate and compare 3D CLSM to laser diffraction (Mastersizer 2000, Malvern Panalytical), using polystyrene microsphere size standards. Next, we apply both methods to evaluate MFG size distributions in human milk. We show that 3D CLSM can be used to obtain more accurate size distributions between 500 nm and 10 μm compared to laser diffraction. Importantly, MFG size distributions obtained with 3D CLSM contain no secondary population around 1 μm, in contrast to laser diffraction measurements. This suggests that the bimodal MFG distribution obtained by laser diffraction can be an artifact of the built-in fitting algorithm, instead of an actual feature of human milk. This work demonstrates that care should be taken when interpreting size distributions of MFGs measured with laser diffraction and that 3D CLSM is an accurate alternative for measuring size distributions in lactation and dairy research.
11 June 2021 in OSA Continuum
Laser speckle contrast imaging (LSCI) is a non-invasive and affordable technique to visualize skin perfusion. Handheld use of the system facilitates measurements on various skin areas in a flexible manner. However, movement artefacts caused by handheld operation or test subject movements hamper its performance. In this work, we study the influence of the laser beam type in handheld-LSCI by evaluating the speckle contrast on static objects for beams with planar, spherical or scrambled wavefronts, and for movement artefacts caused by tilting or translation of wavefronts. We show that the scrambled waves made by often-used engineered diffusers lead to significantly larger movement artefacts than planar or spherical waves.
3 April 2020 in Biomedical Optics Express
Functional performance of handheld laser speckle contrast imaging (LSCI) is compromised by movement artefacts. Here we quantify the movements of a handheld LSCI system employing electromagnetic (EM) tracking and measure the applied translational, tilt and on-surface laser beam speeds. By observing speckle contrast on static objects, the magnitudes of translation and tilt of wavefronts are explored for various scattering levels of the objects. We conclude that for tissue mimicking static phantoms, on-surface speeds play a dominant role to wavefront tilt speed in creation of movement artefacts. The ratio depends on the optical properties of the phantom. Furthermore, with the same applied speed, the drop in the speckle contrast increases with decreasing reduced scattering coefficient, and hence the related movement artefact increases.
29 January 2025 in Journal of Physics: Photonics
Wavefront shaping (WFS) is a technique for controlling the propagation of light. With applications ranging from microscopy to free-space telecommunication, this research field is expanding rapidly. As the field advances, it stands out that many breakthroughs are driven by the development of better software that incorporates increasingly advanced physical models and algorithms. Typical WFS software involves a complex combination of low-level hardware control, signal processing, calibration, troubleshooting, simulation, and the WFS algorithm itself. This complexity makes it hard to compare different algorithms and to extend existing software with new hardware or algorithms. Moreover, the complexity of the software can be a significant barrier for end users of microscopes to adopt WFS. OpenWFS addresses these challenges by providing a modular Python library that separates hardware control from the WFS algorithm itself. Using these elements, a WFS algorithm can be written in a minimal amount of code, with OpenWFS taking care of low-level hardware control, synchronization, and troubleshooting. Algorithms can be used on different hardware or in a completely simulated environment without changing the code. Moreover, we provide full integration with the Micro-Manager microscope control software, enabling WFS experiments to be executed from a user-friendly graphical user interface.