Milk fat globules (MFGs) in human milk provide energy to breastfed infants and support infant development. Accurate measurements of MFG size distributions are important to better understand MFG function and origin, as well as the influence of MFG size on milk composition analysis methods. Nevertheless, commonly used laser diffraction systems have never been thoroughly validated for size distribution measurements in human milk. Here, we introduce a new method for determining the size distribution of milk fat globules in human milk, using 3D confocal laser scanning microscopy (CLSM) in combination with fluorescent labeling of MFGs. We validate and compare 3D CLSM to laser diffraction (Mastersizer 2000, Malvern Panalytical), using polystyrene microsphere size standards. Next, we apply both methods to evaluate MFG size distributions in human milk. We show that 3D CLSM can be used to obtain more accurate size distributions between 500 nm and 10 μm compared to laser diffraction. Importantly, MFG size distributions obtained with 3D CLSM contain no secondary population around 1 μm, in contrast to laser diffraction measurements. This suggests that the bimodal MFG distribution obtained by laser diffraction can be an artifact of the built-in fitting algorithm, instead of an actual feature of human milk. This work demonstrates that care should be taken when interpreting size distributions of MFGs measured with laser diffraction and that 3D CLSM is an accurate alternative for measuring size distributions in lactation and dairy research.
The refractive index (RI) of human milk serum (also known as whey, milk soluble fraction or milk plasma) depends on the individual molecular species dissolved in the serum and their concentrations. Although the human milk serum RI is known to influence milk analysis methods based on light scattering, the RI dependency on human milk serum composition is currently unknown. Therefore, we systematically evaluate how the RI depends on natural variations in macronutrient concentrations in the soluble fraction. We measure RI variations in serum simulating samples with controlled macronutrient concentrations, as well as skimmed and whole fore-, bulk, and hindmilk from 19 donors. For both types of samples, we relate the measured RI to the macronutrient composition. From the serum simulating samples, we observe that the RI depends more on variations in whey protein, than carbohydrate concentrations, while minerals have negligible influence. For all donated samples, the average RI was 1.3470 (range 1.3466–1.3474). Per donor, no significant differences were observed in RI between fore-, bulk, and hindmilk. We conclude that protein and solids-not-fat (i.e., the total contribution of carbohydrates, proteins and minerals present in milk) concentrations are most predictive for human milk serum RI.
Background: Human milk sub-sampling protocols are used in lactation research to estimate milk composition, while minimizing interference with normal breastfeeding. However, macronutrient concentrations in human milk can be highly variable, and the accuracy of sub-sampling protocols for a single breastfeed is currently unknown. Aim: We investigated the accuracy of three milk sub-sampling protocols for estimating the macronutrient concentrations of a complete feed: the mean of pre- and post-feed samples, pre-feed samples only, and post-feed samples only. Method: In this observational study, macronutrient concentrations from each sub-sampling protocol were compared to the volume-weighted average of the complete pumping session, based on foremilk, bulk milk, and hindmilk samples from 15 mothers. Macronutrient concentrations of each milk fraction were measured with a human milk analyzer. Additionally, correlations between macronutrient concentrations and lactation characteristics were studied. Results: Macronutrient concentrations from each sub-sampling protocol were strongly correlated with the volume-weighted average reference concentrations. Significant biases were found for the fat concentration (between -1.3 and +1.9 g/dl, depending on the protocol), but not for protein and carbohydrate concentrations. Conclusions: For the fat concentration, none of the three sub-sampling protocols was accurate. The mean of pre- and post-feed samples could, however, be used for high-fat milk samples where measurement errors exceed the bias (+0.3 g/dl). Pre-feed or post-feed samples only should not be used to estimate the fat concentration of a complete feed. For proteins and carbohydrates, one milk sample taken at any moment in a breastfeed is sufficient to represent the concentration in the complete feed.