Jyunghyun Lee

Prof. Jyunghyun Lee


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
Qun WeiQun Wei
Qun Wei
HPHee-Joon Park
Hee-Joon Park
JLJyunghyun Lee
Jyunghyun Lee
In this paper, a user-friendly and low-cost wireless health monitoring system that measures skin temperature from the back of the body for monitoring the core body temperature is proposed. To measure skin temperature accurately, a semiconductor-based microtemperature sensor with a maximum accuracy of ±0.3°C was chosen and controlled by a high-performance/low-power consumption Acorn-Reduced Instruction Set Computing Machine (ARM) architecture microcontroller to build the temperature measuring device. Relying on a 2.4 GHz multichannel Gaussian frequency shift keying (GFSK) RF communication technology, up to 100 proposed temperature measuring devices can transmit the data to one receiver at the same time. The shell of the proposed wireless temperature-measuring device was manufactured via a 3D printer, and the device was assembled to conduct the performance tests and in vivo experiments. The performance test was conducted with a K-type temperature sensor in a temperature chamber to observe temperature measurement performance. The results showed an error value between two devices was less than 0.1°C from 25 to 40°C. For the in vivo experiments, the device was attached on the back of 10 younger male subjects to measure skin temperature to investigate the relationship with ear temperature. According to the experimental results, an algorithm based on the curve-fitting method was implemented in the proposed device to estimate the core body temperature by the measured skin temperature value. The algorithm was established as a linear model and set as a quadratic formula with an interpolant and with each coefficient for the equation set with 95% confidence bounds. For evaluating the goodness of fit, the sum of squares due to error (SSE), R-square, adjusted R-square, and root mean square error (RMSE) values were 33.0874, 0.0212, 0.0117, and 0.3998, respectively. As the experimental results have shown, the mean value for an error between ear temperature and estimated core body temperature is about ±0.19°C, and the mean bias is 0.05 ± 0.14°C when the subjects are in steady status.

15 September 2017 in Computer Assisted Surgery
Verified
Journal Article
Open access
KSKi Woong Seong
Ki Woong Seong
SNSung Dae Na
Sung Dae Na
YPYoung Sik Park
Young Sik Park
HPHee-Joon Park
Hee-Joon Park
MKMyoung Nam Kim
Myoung Nam Kim
JLJyunghyun Lee
Jyunghyun Lee
The increase in mortality associated with arrhythmia is an inevitable problem of modern society such as westernized eating habits and an increase in stress due to industrialization, and the related social costs are increasing. In this regard, the supply of automatic external defibrillator (AED) used outside hospitals is increasing mainly in public institutions, and AED is a medical practice performed by non-medical personnel. Therefore, studies on arrhythmia detection algorithm to make accurate clinical judgment for proper use are increasing. In this paper, we propose a time domain analysis method to detect arrhythmia in real time and implement AED by porting it to programmable gate array and digital signal processor. The analysis of the phase domain improves the detection rate of R-peak using the differentiated electrocardiogram (ECG) waveform rather than the existing ECG waveform and makes it easy to distinguish the normal ECG from the arrhythmia signal in the phase domain. The proposed algorithm was verified by simulation using Labview and ModelSim, and it was verified that the proposed algorithm works effectively by performing animal experiments using the implemented AED.

25 March 2021 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
SBSang Kwang Bang
Sang Kwang Bang
KSKi Woong Seong
Ki Woong Seong
MKMyoung Nam Kim
Myoung Nam Kim
JLJyunghyun Lee
Jyunghyun Lee
BACKGOROUND AND OBJECTIVE: Cardiovascular disorders are increasing because of poor eating habits, excessive drinking, and lack of exercise. Some of the typical cardiovascular surgical procedures utilize catheters. Catheter-based procedures require the surgeons to have extensive experience and high proficiency at performing vascular interventions. However, the learning period to acquire such proficiency is lengthy and the opportunities for practical training and mastery are insufficient. Therefore, due to insufficient skill, dangerous situations with damage or rupture of the patient’s blood vessels may occur, thereby increasing the risk of medical accidents. Hence, it is necessary to have experience and proficiency for performing vascular interventions. Thus, it is necessary to develop a simulator to shorten learning time and reduce medical accidents. METHODS: In this study, we developed a position detection system for the simulator to use physical models to learn cardiovascular surgical intervention techniques. The developed system uses changes in the output values of a Hall sensor based on the position of a permanent magnet. RESULTS AND CONCLUSIONS: From the changing output values, the distance calculation equation is derived, and the position of the permanent magnet is effectively estimated from the calculations. The performance of the position detecting system was tested, and the results proved that the system could be sufficiently used as a simulator.

1 January 2018 in Filomat
Verified
Journal Article
Open access
PDF file
YPYoung Sik Park
Young Sik Park
Sungdae NaSungdae Na
Sungdae Na
Qun WeiQun Wei
Qun Wei
KSKiWoong Seong
KiWoong Seong
JLJyunghyun Lee
Jyunghyun Lee
JCJin-Ho Cho
Jin-Ho Cho
Recently, various technologies and sciences are developed for fourth industrial revolution which includes artificial intelligence, robotics, internet of things, 3-D printing, and autonomous transportation. The autonomous transportation is one of the fourth industrial technology, and has been studying for safety driving. Accurate lane detection and lane departure warning system is very important for autonomous transportation. However, conventional methods have some problems of applying real-driving such as extracting miss lanes under cloudy weather and vehicle disturbance situations. In order to solve the real driving problems, we propose a new lane detection technique for lane departure and forward collision warning system using a single in-vehicle camera. The proposed method consists of triangular lane model, feature points extraction method. In the near field, a triangular lane model is used to approximate a pair of lane boundaries. Subsequently, feature points extraction method based on hyperbola curve model is applied to obtain lane curvature in the far field. Mathematical B-spline applied to feature points for curved lane fitting. Simulation results show that the proposed lane detection and tracking method has good performance.

19 May 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KSKiWoong Seong
KiWoong Seong
JCJin-Ho Cho
Jin-Ho Cho
MKMyoung Nam Kim
Myoung Nam Kim
DSDong Ho Shin
Dong Ho Shin
JLJyunghyun Lee
Jyunghyun Lee
We demonstrated that focusing an ultrasonic beam on the eardrum can overcome the high-frequency sensitivity limitations and acoustic distortion of conventional hearing aid receivers. Multilayer PZT was used for an ultrasonic receiver that operates at low voltage and enters the external auditory canal, and a 3 mm radius radiator was designed to radiate the focused parametric acoustic signal to the center of the eardrum based on an acoustic analysis according to the frequency. To this end, an ultrasonic earphone consisting of a radiator attached to multilayer PZT and a 130 kHz parametric ultrasonic modulator was implemented; vibration and sound pressure were measured using a laser vibrometer and a tube-type microphone. The proposed parametric ultrasonic receiver generates an average sound pressure of 70 dB SPL at a frequency of 1~10 kHz with a 10 Vpeak applied voltage; this was implemented to provide a higher output in the range of 5 kHz and above, which is difficult to cover with existing receivers.

25 March 2021 in Technology and Health Care
Verified
Journal Article
Open access
PDF file
JKJong Hoon Kim
Jong Hoon Kim
MPMin Gyu Park
Min Gyu Park
QWQun Wei
Qun Wei
KSKi Woong Seong
Ki Woong Seong
JLJyunghyun Lee
Jyunghyun Lee
BACKGROUND: Sound normally enters the ear canal, passes through the middle ear, and stimulates the cochlea through the oval window. Alternatively, the cochlea can be stimulated in a reverse manner, namely round window stimulation. The reverse stimulation is not well understood, partly because in classic lumped-parameter models the path of reverse drive during the round window stimulation is usually not considered. OBJECTIVE: The study goal is to gain a better understanding of the hearing mechanism during round window stimulation. METHODS: A piezo actuator was coupled to the oval and round window of the guinea pigs. The auditory brainstem response produced by the forward and reverse stimulation at four frequencies was recorded. RESULTS: The results show that the input voltage of the actuator required at the hearing threshold in the round window drive was higher than that in the oval window drive. In order to understand the data, we designed a lumped-parameter cochlear model that can simulate both forward and reverse drive. The model-predicted results were consistent with the experimental results. CONCLUSIONS: The response of the auditory system to stimulus of oval window and round window was quantified through animal experimentation, and guinea pigs were used as experimental animals. When the same stimulus was applied to the oval window and round window of the cochlea, the ABR signals were compared. A lumped parameter model was designed to incorporate the sound transmission paths in both oval and round window stimulation. The simulated results are consistent with those of animal experiments. This model will be useful in understanding the inner-ear response in round window.