Sarra Takita

Dr. Sarra Takita

Sheffield Hallam University, MERI Material and Engineering Research Institute & BMRC Biomolecular Sciences Research Centre
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
Alexei NabokAlexei Nabok
Alexei Nabok
HAHisham Abu-Ali
Hisham Abu-Ali
STSarra Takita
Sarra Takita
DSDavid Smith
David Smith
This paper reports on a feasibility study of electrochemical in-vitro detection of prostate cancer biomarker PCA3 (prostate cancer antigen 3) in direct assay with specific RNA aptamer labelled with a redox group (ferrocene) and immobilized on a screen-printed gold electrode surface. The cyclic voltammograms and electrochemical impedance spectroscopy methods yield encouraging results on the detection of PCA3 in a range of concentrations from 1 μg/mL down to 0.1 ng/mL in buffer solutions. Both anodic and cathodic current values in cyclic voltammograms measurements and charge transfer resistance values in electrochemical impedance spectroscopy experiments correlate with the PCA3 concentration in the sample. Kinetics studies of the binding of the PCA3 to our aptamer demonstrated high specificity of the reaction with a characteristic affinity constant of approximately 4·10−10 molar. The results of this work provide a background for the future development of novel, highly sensitive and cost-effective diagnostic methodologies for prostate cancer detection.

16 March 2024 in Biosensors and Bioelectronics: X
Verified
Journal Article
Open access
STSarra Takita
Sarra Takita
ANAlexi Nabok
Alexi Nabok
MMMagdi Mussa
Magdi Mussa
MKMatthew Kitchen
Matthew Kitchen
ALAnna Lishchuk
Anna Lishchuk
DSDavid Smith
David Smith

14 February 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
STSarra Takita
Sarra Takita
ANAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
DSDavid Smith
David Smith
This is a continuation of our research into the development of novel biosensing technologies for early diagnostics of prostate cancer (PCa). The existing PCa diagnostics based on PSA detection (prostate cancer antigen) in blood serum often yield controversial outcomes and require improvement. At the same time, the long non-coded RNA transcript PCA3 overexpressed in PCa patients’ urine proved to be an ideal biomarker for PCa diagnosis, and recent research mainly focuses on developing biosensors for the detection of PCA3. One of the most promising directions in this research is the use of aptamers as bio-receptors for PCA3. We demonstrated the earlier great potential of electrochemical sensors exploiting aptamer labelled with redox group ferrocene. In this work, we use the RNA-based aptamer specific to 227 nt fragment of lncRNA PCA3 labelled with methylene blue redox label which offers a higher affinity to PCA3 than commonly used DNA-based aptamers. Before proceeding with biosensing experiments, the gold screen-printed electrodes were cleaned by CV scanning in a sulfuric acid solution, which removed surface contaminations and thus improved immobilization of aptamers. The quality of the gold surface was assessed by contact angle measurements. Moreover, the concentration of immobilized aptamers was optimized to achieve the best results in electrochemical measurements. Initial tests were carried out using cyclic voltammograms (CV) measurements and showed a correlation between oxidation/reductions peaks intensities and the concentration of PCA3. Such experiments proved the main concept of the proposed apta-sensing, e.g., the changes of aptamer secondary structure during binding the target (PCA3) resulting in redox labels coming closer to the electrode surface and thus increasing the charge transfer. The lowest recorded concentration of PCA3 was 0.01 nM in CV measurements, which is close to the LDL level for this method. Much more promising results were obtained with the electrochemical impedance spectroscopy (EIS) measurements, which showed remarkable features of increasing sensitivity at low concentrations of PCA3. The extrapolation of data below 0.05 nM level allowed estimating LDL of about 0.4 pM. The results obtained are very encouraging and constitute a major step towards developing a simple, reliable, and cost-effective diagnostic tool for the early detection of prostate cancer.

Verified
Journal Article
Open access
PDF file
STSarra Takita
Sarra Takita
Alexei NabokAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
DSDavid Smith
David Smith
This work is a continuation of our research into the development of simple, reliable, and cost-effective methods for the early diagnosis of prostate cancer (PCa). The proposed method is based on the electrochemical detection of the PCA3 biomarker of PCa (long non-coded RNA transcript expressed in urine) using a specific aptamer labeled with a redox group (methylene blue). The electrochemical measurements (cyclic voltammograms) obtained from electrodes functionalized with the aptamer were complemented in this work by another biosensing technique: total internal reflection ellipsometry (TIRE). In addition to proving the concept of the detection of PCA3 in low concentrations down to 90 pM, this study improved our understanding of the processes by which PCA3 binds to its specific aptamer. The high specificity of the binding of PCA3 to the aptamer was assessed by studying the binding kinetics, which yielded an affinity constant (KD) of 2.58 × 10−9 M. Additional XPS measurements confirmed the strong covalent binding of aptamers to gold and showed spectral features associated with PCA3 to aptamer binding.

30 June 2021 in Chemistry Proceedings
Verified
Conference Paper
Open access
PDF file
STSarra Takita
Sarra Takita
Alexei NabokAlexei Nabok
Alexei Nabok
DSDavid Smith
David Smith
ATAnna Tsargorodska
Anna Tsargorodska
The most common prostate cancer (PCa) diagnostics, which are based on detection of prostate-specific antigens (PSA) in blood, have specificity limitations often resulting in both false-positive and false-negative results; therefore, improvement in PCa diagnostics using more specific PCa biomarkers is of high importance. Studies have shown that the long noncoding RNA Prostate Cancer Antigen 3 (lncPCA3) that is over-expressed in the urine of prostate cancer patients is an ideal biomarker for non-invasive early diagnostics of PCa. Geno-sensors based on aptamer bioreceptors (aptasensors) offer cost- and time-effective, and precise diagnostic tools for detecting PCa biomarkers. In this study, we report on further developments of RNA-based aptasensors exploiting optical (spectroscopic ellipsometry) measurements in comparison with electrochemical (CV and IS) measurements published earlier. These sensors were made by immobilization of thiolated CG-3 RNA aptamers on the surface of gold. Instead of a redox-labelled aptamer used previously in electrochemical measurements, a non-labelled aptamer was used here in a combination with total internal reflection ellipsometry (TIRE) measurements. The results obtained by these two methods were compared. The method of TIRE is potentially highly sensitive and comparable in that respect with electrochemical methods capable of detection of PCA3 in sub-pM levels of concentration. The required selectivity is provided by the high affinity of PCA3-to-aptamer binding with KD in the 10−9 M range. The spectroscopic ellipsometry measurements provided additional information on the processes of PCA3 to aptamer binding.

30 October 2021 in Materials Proceedings
Verified
Conference Paper
Open access
PDF file
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
YRYaqub Rahaq
Yaqub Rahaq
STSarra Takita
Sarra Takita
FZFarah D. Zahoor
Farah D. Zahoor
NFNicholas Farmilo
Nicholas Farmilo
OLOliver Lewis
Oliver Lewis
Silica-based coatings prepared using sol-gel polymerizing technology have been shown to exhibit excellent chemical stability combined with reducing the corrosion of metal substrates, showing promising use in aerospace and marine applications to protect light alloys. Moreover, this technology is an eco-friendly technique route for producing surface coatings, showing high potential for replacing toxic pre-treatment coatings of traditional conversation chromate coatings. This study aims to investigate the enhancement in corrosion protection of a hybrid-organic-inorganic silica-based coating cured at 80 °C by increasing the hydrophobicity to work on the aluminium 2024-T3 alloy. This approach involving a novel silica-based hybrid coating was prepared by introducing 1H,1H,2H,2H-perfluorodecyltriethoxysilane (PFDTES) into the base hybrid formula created from tetraethylorthosilicatesilane (TEOS) and triethoxymethylsilane (MTMS) precursors; this formula was enhanced by introducing a Polydimethylsiloxane polymer (PDMS). The corrosion protection properties of these coatings were examined by being immersed in 3.5% NaCl with electrochemical impedance testing (EIS) and Potentiodynamic polarization scanning (PDPS). The chemical elements confirmation was performed using infrared spectroscopy (ATR-FTIR); all this was supported by analysing the surface morphology before and after the immersion by using scanning electron microscopy (SEM). The results of the electrochemical impedance testing analyses reveal the new open finite-length diffusion circuit element due to electrolyte media diffusion prevented by fluorinated groups. Additionally, it shows increases in corrosion protection arising from the increasing hydrophobicity of the fluorinated coating compared to other formulas cured under similar conditions and bare substrate. Additionally, the modified sol-gel exhibited improved resistance to cracking, while the increased hydrophobicity may also promote self-cleaning.