Anna Lishchuk

Dr. Anna Lishchuk


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2023 in Eng
Verified
Journal Article
Open access
PDF file
STSarra Takita
Sarra Takita
ANAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
DSDavid Smith
David Smith
In the quest for the development of accurate, reliable, and cost-effective biosensing technology for early diagnostics of prostate cancer, we describe here an electrochemical biosensor combining a simple transducing method of differential pulse voltammetry (DPV) with an RNA-based aptamer labelled with a methylene blue redox group acting as a highly specific bioreceptor to the prostate cancer biomarker PCA3. A series of DPV measurements on screen-printed gold electrodes is functionalised with a redox-labelled aptamer in solutions (either buffer or synthetic urine) containing PCA3 in a wide range of concentrations from 0.1 picomolar (pM) to 10 nanomolar (nM). In these measurements, the current peak values correlate with the concentration of PCA3 and yield a low detection limit (LDL) of 0.1 pM. Furthermore, the binding kinetics study revealed the high affinity of the aptamer to the target PCA3 with the affinity constants KD of about 3.0 × 10−8 molar. In addition, the AFM study showed the increase in the molecular layer roughness caused by the binding of PCA3, which is a large RNA molecular fragment.

14 February 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
STSarra Takita
Sarra Takita
ANAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
DSDavid Smith
David Smith
This is a continuation of our research into the development of novel biosensing technologies for early diagnostics of prostate cancer (PCa). The existing PCa diagnostics based on PSA detection (prostate cancer antigen) in blood serum often yield controversial outcomes and require improvement. At the same time, the long non-coded RNA transcript PCA3 overexpressed in PCa patients’ urine proved to be an ideal biomarker for PCa diagnosis, and recent research mainly focuses on developing biosensors for the detection of PCA3. One of the most promising directions in this research is the use of aptamers as bio-receptors for PCA3. We demonstrated the earlier great potential of electrochemical sensors exploiting aptamer labelled with redox group ferrocene. In this work, we use the RNA-based aptamer specific to 227 nt fragment of lncRNA PCA3 labelled with methylene blue redox label which offers a higher affinity to PCA3 than commonly used DNA-based aptamers. Before proceeding with biosensing experiments, the gold screen-printed electrodes were cleaned by CV scanning in a sulfuric acid solution, which removed surface contaminations and thus improved immobilization of aptamers. The quality of the gold surface was assessed by contact angle measurements. Moreover, the concentration of immobilized aptamers was optimized to achieve the best results in electrochemical measurements. Initial tests were carried out using cyclic voltammograms (CV) measurements and showed a correlation between oxidation/reductions peaks intensities and the concentration of PCA3. Such experiments proved the main concept of the proposed apta-sensing, e.g., the changes of aptamer secondary structure during binding the target (PCA3) resulting in redox labels coming closer to the electrode surface and thus increasing the charge transfer. The lowest recorded concentration of PCA3 was 0.01 nM in CV measurements, which is close to the LDL level for this method. Much more promising results were obtained with the electrochemical impedance spectroscopy (EIS) measurements, which showed remarkable features of increasing sensitivity at low concentrations of PCA3. The extrapolation of data below 0.05 nM level allowed estimating LDL of about 0.4 pM. The results obtained are very encouraging and constitute a major step towards developing a simple, reliable, and cost-effective diagnostic tool for the early detection of prostate cancer.

Verified
Journal Article
Open access
PDF file
STSarra Takita
Sarra Takita
Alexei NabokAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
DSDavid Smith
David Smith
This work is a continuation of our research into the development of simple, reliable, and cost-effective methods for the early diagnosis of prostate cancer (PCa). The proposed method is based on the electrochemical detection of the PCA3 biomarker of PCa (long non-coded RNA transcript expressed in urine) using a specific aptamer labeled with a redox group (methylene blue). The electrochemical measurements (cyclic voltammograms) obtained from electrodes functionalized with the aptamer were complemented in this work by another biosensing technique: total internal reflection ellipsometry (TIRE). In addition to proving the concept of the detection of PCA3 in low concentrations down to 90 pM, this study improved our understanding of the processes by which PCA3 binds to its specific aptamer. The high specificity of the binding of PCA3 to the aptamer was assessed by studying the binding kinetics, which yielded an affinity constant (KD) of 2.58 × 10−9 M. Additional XPS measurements confirmed the strong covalent binding of aptamers to gold and showed spectral features associated with PCA3 to aptamer binding.

11 April 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
ECEvelin Csanyi
Evelin Csanyi
DHDeborah Hammond
Deborah Hammond
BBBenjamin Bower
Benjamin Bower
EJEdwin Johnson
Edwin Johnson
ALAnna Lishchuk
Anna Lishchuk
GLGraham Leggett
Graham Leggett
X-ray photoelectron spectroscopy (XPS) depth-profiling with an argon gas cluster ion source (GCIS) was used to characterize the spatial distribution of chlorophyll a (Chl) within a poly(cysteine methacrylate) (PCysMA) brush grown by surface-initiated atom-transfer radical polymerization (ATRP) from a planar surface. The organization of Chl is controlled by adjusting the brush grafting density and polymerization time. For dense brushes, the C, N, S elemental composition remains constant throughout the 36 nm brush layer until the underlying gold substrate is approached. However, for either reduced density brushes (mean thickness 20 nm) or mushrooms grown with reduced grafting densities (mean thickness 6-9 nm), elemental intensities decrease continuously throughout the brush layer, because photoelectrons are less strongly attenuated for such systems. For all brushes, the fraction of positively charged nitrogen atoms (N+/N0) decreases with increasing depth. Chl binding causes a marked reduction in N+/N0 within the brushes and produces a new feature at 398.1 eV in the N1s core-line spectrum assigned to tetrapyrrole ring nitrogen atoms coordinated to Zn2+. For all grafting densities, the N/S atomic ratio remains approximately constant as a function of brush depth, which indicates a uniform distribution of Chl throughout the brush layer. However, a larger fraction of repeat units bound to Chl is observed at lower grafting densities, reflecting a progressive reduction in steric congestion that enables more uniform distribution of the bulky Chl units throughout the brush layer. In summary, XPS depth-profiling using a GCIS is a powerful tool for characterization of these complex materials.

10 April 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
ECEvelin Csanyi
Evelin Csanyi
DHDeborah Hammond
Deborah Hammond
BBBenjamin Bower
Benjamin Bower
EJEdwin Johnson
Edwin Johnson
ALAnna Lishchuk
Anna Lishchuk
GLGraham Leggett
Graham Leggett
X-ray photoelectron spectroscopy (XPS) depth-profiling with an argon gas cluster ion source (GCIS) was used to characterize the spatial distribution of chlorophyll a (Chl) within a poly(cysteine methacrylate) (PCysMA) brush grown by surface-initiated atom-transfer radical polymerization (ATRP) from a planar surface. The organization of Chl is controlled by adjusting the brush grafting density and polymerization time. For dense brushes, the C, N, S elemental composition remains constant throughout the 36 nm brush layer until the underlying gold substrate is approached. However, for either reduced density brushes (mean thickness 20 nm) or mushrooms grown with reduced grafting densities (mean thickness 6-9 nm), elemental intensities decrease continuously throughout the brush layer, because photoelectrons are less strongly attenuated for such systems. For all brushes, the fraction of positively charged nitrogen atoms (N+/N0) decreases with increasing depth. Chl binding causes a marked reduction in N+/N0 within the brushes and yields a new feature at 398.1 eV in the N1s spectrum assigned to tetrapyrrole ring nitrogen atoms coordinated to Zn2+. For all grafting densities, the N/S ratio remains approximately constant as a function of brush depth, which indicates a uniform distribution of Chl throughout the brush layer. However, a larger fraction of repeat units bound to Chl is observed at lower grafting densities, reflecting a progressive reduction in steric congestion that enables more uniform distribution of the bulky Chl units throughout the brush layer. In summary, XPS depth-profiling using a GCIS is a powerful tool for characterization of these complex materials.

19 April 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
STSarra Takita
Sarra Takita
Alexei NabokAlexei Nabok
Alexei Nabok
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
ASAbdalrahem Ab Shtawa
Abdalrahem Ab Shtawa
ALAnna Lishchuk
Anna Lishchuk
DSDavid Smith
David Smith
Prostate cancer (PCa) remains one of the most prevalent urological malignancies worldwide, with early and accurate diagnosis being critical for improving patient outcomes. Traditional screening approaches, such as digital rectal examination and prostate-specific antigen (PSA) testing, have long served as frontline tools; however, their limited specificity and sensitivity contribute to high rates of false positives, unnecessary biopsies, and overtreatment. Recent UK guidelines and international consensus increasingly question the role of PSA-based population screening, advocating for risk-stratified pathways and multiparametric MRI as first-line investigations. In parallel, advances in molecular biology have identified promising cancer-specific biomarkers, such as prostate cancer antigen 3 (PCA3) and transmembrane protease serine 2 (TMPRSS2:ERG), that outperform PSAs in terms of specificity and prognostic value. These developments have catalysed innovation in biosensor technologies, enabling rapid, cost-effective, and non-invasive detection of single and multiplex biomarkers in urine and serum. Electrochemical and optical affinity-based biosensors offer transformative potential for the development of personalised point-of-care platforms and diagnostics, reducing the reliance on invasive procedures and improving clinical decision-making. The latter can be augmented with artificial intelligence (AI) tools. This review critically examines the limitations of PSAs, synthesises evidence on novel biomarkers and imaging-led strategies, and evaluates the design, performance, and translational challenges of biosensor-based assays. Furthermore, it outlines future directions, including standardisation, large-scale clinical validation, and integration of multiplex biosensors with AI for precision diagnostics. By bridging molecular insights with engineering innovations, these approaches promise to redefine PCa screening and enable accurate, patient-centred care.