Magdi Hassn B. Mussa

Dr. Magdi Hassn B. Mussa

Sheffield Hallam University, Sheffield, UK
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2023 in Eng
Verified
Journal Article
Open access
PDF file
STSarra Takita
Sarra Takita
ANAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
DSDavid Smith
David Smith
In the quest for the development of accurate, reliable, and cost-effective biosensing technology for early diagnostics of prostate cancer, we describe here an electrochemical biosensor combining a simple transducing method of differential pulse voltammetry (DPV) with an RNA-based aptamer labelled with a methylene blue redox group acting as a highly specific bioreceptor to the prostate cancer biomarker PCA3. A series of DPV measurements on screen-printed gold electrodes is functionalised with a redox-labelled aptamer in solutions (either buffer or synthetic urine) containing PCA3 in a wide range of concentrations from 0.1 picomolar (pM) to 10 nanomolar (nM). In these measurements, the current peak values correlate with the concentration of PCA3 and yield a low detection limit (LDL) of 0.1 pM. Furthermore, the binding kinetics study revealed the high affinity of the aptamer to the target PCA3 with the affinity constants KD of about 3.0 × 10−8 molar. In addition, the AFM study showed the increase in the molecular layer roughness caused by the binding of PCA3, which is a large RNA molecular fragment.

14 February 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
STSarra Takita
Sarra Takita
ANAlexei Nabok
Alexei Nabok
ALAnna Lishchuk
Anna Lishchuk
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
DSDavid Smith
David Smith
This is a continuation of our research into the development of novel biosensing technologies for early diagnostics of prostate cancer (PCa). The existing PCa diagnostics based on PSA detection (prostate cancer antigen) in blood serum often yield controversial outcomes and require improvement. At the same time, the long non-coded RNA transcript PCA3 overexpressed in PCa patients’ urine proved to be an ideal biomarker for PCa diagnosis, and recent research mainly focuses on developing biosensors for the detection of PCA3. One of the most promising directions in this research is the use of aptamers as bio-receptors for PCA3. We demonstrated the earlier great potential of electrochemical sensors exploiting aptamer labelled with redox group ferrocene. In this work, we use the RNA-based aptamer specific to 227 nt fragment of lncRNA PCA3 labelled with methylene blue redox label which offers a higher affinity to PCA3 than commonly used DNA-based aptamers. Before proceeding with biosensing experiments, the gold screen-printed electrodes were cleaned by CV scanning in a sulfuric acid solution, which removed surface contaminations and thus improved immobilization of aptamers. The quality of the gold surface was assessed by contact angle measurements. Moreover, the concentration of immobilized aptamers was optimized to achieve the best results in electrochemical measurements. Initial tests were carried out using cyclic voltammograms (CV) measurements and showed a correlation between oxidation/reductions peaks intensities and the concentration of PCA3. Such experiments proved the main concept of the proposed apta-sensing, e.g., the changes of aptamer secondary structure during binding the target (PCA3) resulting in redox labels coming closer to the electrode surface and thus increasing the charge transfer. The lowest recorded concentration of PCA3 was 0.01 nM in CV measurements, which is close to the LDL level for this method. Much more promising results were obtained with the electrochemical impedance spectroscopy (EIS) measurements, which showed remarkable features of increasing sensitivity at low concentrations of PCA3. The extrapolation of data below 0.05 nM level allowed estimating LDL of about 0.4 pM. The results obtained are very encouraging and constitute a major step towards developing a simple, reliable, and cost-effective diagnostic tool for the early detection of prostate cancer.

30 October 2021 in Materials Proceedings
Verified
Conference Paper
Open access
PDF file
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
YRYaqub Rahaq
Yaqub Rahaq
STSarra Takita
Sarra Takita
FZFarah D. Zahoor
Farah D. Zahoor
NFNicholas Farmilo
Nicholas Farmilo
OLOliver Lewis
Oliver Lewis
Silica-based coatings prepared using sol-gel polymerizing technology have been shown to exhibit excellent chemical stability combined with reducing the corrosion of metal substrates, showing promising use in aerospace and marine applications to protect light alloys. Moreover, this technology is an eco-friendly technique route for producing surface coatings, showing high potential for replacing toxic pre-treatment coatings of traditional conversation chromate coatings. This study aims to investigate the enhancement in corrosion protection of a hybrid-organic-inorganic silica-based coating cured at 80 °C by increasing the hydrophobicity to work on the aluminium 2024-T3 alloy. This approach involving a novel silica-based hybrid coating was prepared by introducing 1H,1H,2H,2H-perfluorodecyltriethoxysilane (PFDTES) into the base hybrid formula created from tetraethylorthosilicatesilane (TEOS) and triethoxymethylsilane (MTMS) precursors; this formula was enhanced by introducing a Polydimethylsiloxane polymer (PDMS). The corrosion protection properties of these coatings were examined by being immersed in 3.5% NaCl with electrochemical impedance testing (EIS) and Potentiodynamic polarization scanning (PDPS). The chemical elements confirmation was performed using infrared spectroscopy (ATR-FTIR); all this was supported by analysing the surface morphology before and after the immersion by using scanning electron microscopy (SEM). The results of the electrochemical impedance testing analyses reveal the new open finite-length diffusion circuit element due to electrolyte media diffusion prevented by fluorinated groups. Additionally, it shows increases in corrosion protection arising from the increasing hydrophobicity of the fluorinated coating compared to other formulas cured under similar conditions and bare substrate. Additionally, the modified sol-gel exhibited improved resistance to cracking, while the increased hydrophobicity may also promote self-cleaning.

15 October 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
FZF. Deeba Zahoor
F. Deeba Zahoor
OLOliver Lewis
Oliver Lewis
NFNicholas Farmilo
Nicholas Farmilo
The inherent reactivity of Al–Cu–Mg alloys is such that their use for building structural, maritime, and airplane components with great strength/weight ratios would not be possible without good anti-corrosion systems. These systems could be considered as imitations of the protection mechanism found in the conventional hexavalent chromium-based system, but with additional limited environmental impact, and in particular without toxic or carcinogenic effects. These coatings also are intended to be eco-friendly, using less of the valuable raw materials and energy than more traditional methods. Silica-based hybrid protective coatings have been shown to exhibit excellent chemical stability combined with the ability to reduce the corrosion of metal substrates. However, research shows that sol–gel has some limitations in terms of the period of the anti-corrosive properties. Therefore, this work reports the performance of a silica-based hybrid sol–gel coating encapsulated with benzimidazole (BZI) that can be applied to light alloys to form an inherently inhibited and crack-free coating. This coating was applied on AA 2024-T3 and cured at 80 °C. The high corrosion resistance performance results from the combination of good adhesion, the hydrophobic property of the silica-based hybrid coating, and the presence of the encapsulated (BZI) film-forming volatile corrosion inhibitor, which is released at pores within the coating system, resulting in film-forming, reducing the reaction at cathodic sites. The evaluation of this mechanism is based on using electrochemical testing techniques. The anti-corrosion properties of the coatings were studied when immersed in 3.5% NaCl by using electrochemical impedance spectroscopy (EIS) and potential-dynamic polarization scanning (PDPS). The chemical confirmation was performed by infrared spectroscopy (ATR-FTIR), supported by analyzing the morphology of the surface before and after the immersion testing by using scanning electron microscopy (SEM). The benzimidazole-silica-based hybrid coating exhibited excellent anti-corrosion properties, providing an adherent protective film on the aluminum alloy 2024-T3 samples compared to sol–gel-only and bare metals, as a cost-effective and eco-friendly system.

15 October 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
OLOliver Lewis
Oliver Lewis
OLOliver Lewis
Oliver Lewis
Sol-gel coatings provide environmentally friendly surface protection for metals and can replace toxic pre-treatments such as those based on hexavalent chromium on metal alloys. This project ultimately aims to develop silica-based organic–inorganic sol-gel derived thin film coatings possessing anti-corrosion and anti-fouling properties on aluminium alloy substrates. As with any coating, sample preparation plays a significant role in the performance of a sol-gel coating. Therefore, it was necessary to define a preparation method that combines the removal of contaminants and surface roughening to improve adhesion and reproducibility. Four techniques were investigated: fine abrasive sandpaper cleaning, acetone degreasing only and cleaning with an industrial-available alkaline cleaner for 5 min and 30 min.

15 October 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MMMagdi Hassn B. Mussa
Magdi Hassn B. Mussa
MDMahmoud Dukali
Mahmoud Dukali
YRYaqub Rahaq
Yaqub Rahaq
Corrosion and maintenance anomaly and integrity management systems (AIMS) are now the foundation of many industrial and engineering systems regarding sustainability and long-lasting assets. The oil and gas industry has started developing new, integrated management systems to keep its assets safe from real external failures. However, the overlapping of assets’ integrity responsibilities occur when a conflict of interests, such as production, safety, environmental, and financial interfacing, are inaccurately weighed against each other. This paper will review the case study of the anomaly and integrity management systems implemented on the Sabratha offshore platform. In order to achieve sustainable asset implementation, it is essential to identify the different weights given to the critical factors controlling the operational anomaly and integrity of facilities on offshore platforms and re-classify the potential failures. Therefore, design practices are reviewed. Moreover, inspection techniques and strategies are re-assessed and used to describe the consistent integrity assessment techniques linked to anomaly monitoring and maintenance criteria. Finally, the anomaly and integrity management system design use activity, process models, structures, and flow diagrams are reviewed. This work will be helpful for the further enhancement of a new machine learning system to support this approach.