SASI BHUSHAN M. A.

Mr. SASI BHUSHAN M. A.

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
SASASI BHUSHAN M. A.
SASI BHUSHAN M. A.
SMSudhakaran Mahalingam
Sudhakaran Mahalingam
SDSattianadan Dasarathan
Sattianadan Dasarathan
MEMariappane Egambarame
Mariappane Egambarame
A peak shaving approach in selected industrial loads helps minimize power usage during high demand hours, decreasing total energy expenses while improving grid stability. A battery energy storage system (BESS) can reduce peak electricity demand in distribution networks. Quasi-dynamic load flow analysis (QLFA) accurately assesses the maximum loading conditions in distribution networks by considering factors such as load profiles, system topology, and network constraints. Achieving maximum peak shaving requires optimizing battery charging and discharging cycles based on real-time energy generation and consumption patterns. Seamless integration of battery storage with solar photovoltaic (PV) systems and industrial processes is essential for effective peak shaving strategies. This paper proposes a model predictive control (MPC) scheme that can effectively perform peak shaving of the total industrial load. Adopting an MPC-based algorithm design framework enables the development of an effective control strategy for complex systems. The proposed MPC methodology was implemented and tested on the Indian Utility 29 Node Distribution Network (IU29NDN) using the DIgSILENT Power Factory environment. Additionally, the analysis encompasses technical and economic results derived from a simulated storage operation and, taking Puducherry State Electricity Department tariff details, provides significant insights into the application of this method.

Verified
Journal Article
Open access
PDF file
SASASI BHUSHAN M. A.
SASI BHUSHAN M. A.
SMSudhakaran Mahalingam
Sudhakaran Mahalingam
SDSattianadan Dasarathan
Sattianadan Dasarathan
SVSowmyasree Vemuri
Sowmyasree Vemuri
Distributed generation strengthens distribution network reliability by placing generators close to load centers. The integration of electric vehicle charging stations (EVCSs) with PV systems mitigates the effects of EV charging burden. In this research, the objective is to combineEVCSs with distributed generation (DG) units in the Puducherry smart grid system to obtain optimized locations and enhance their reliability. To determine the right nodes for DGs and EVCSs in an uneven distribution network, the modified decision-making (MDM) algorithm and the model predictive control (MPC) approach are used. The Indian utility 29-node distribution network (IN29NDN), which is an unbalanced network, is used for testing. The effects of PV systems and EVCS units are studied in several settings and at various saturation levels. This study validates the correctness of its findings by evaluating the outcomes of proposed methodological approaches. DIgSILENT Power Factory is used to conduct the simulation experiments. The results show that optimizing the location of the DG unit and the size of the PV system can significantly minimize power losses and make a distribution network (DN) more reliable.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
SASASI BHUSHAN M. A.
SASI BHUSHAN M. A.
SMSudhakaran Mahalingam
Sudhakaran Mahalingam
Time-series quasi-dynamic load flow analysis becomes mandatory to determine voltage profiles across various nodes in modern distribution network to meet out the standards and requirements of the consumers. This paper describes the necessity of time- series load flow analysis (LFA) for a practical distribution network in Puducherry smart grid system by considering seasonal load variations in the union territory of Puducherry, India. The suitability of this load flow analysis is demonstrated on the IEEE 69, IEEE 37, IEEE 34 node test systems and compared with the practical Indian utility 29 node distribution network (IU29NDN) in Puducherry smart grid system having unbalanced load patterns and nexus among the sources of energy. A Modified Decision Making (MDM) algorithm has been proposed in this paper for determining the size and placement of solar photo voltaic (SPV) system as distributed generation (DG) in the distribution network (DN) to improve the voltage profile of the nodes with sensitive loads. Quasi-dynamic load flow simulations are performed for the test systems over a period of 24 hours with 15-minute step size to estimate the variations in the node voltage, real power and reactive power flows in the distribution networks subjected to seasonal load variations. Furthermore, a harmonic power flow is illustrated, which considers nonlinear loads and distribution network harmonics to elucidate harmonic power flow and obtain harmonics in voltage, current and harmonic distortion in IU29NDN active and reactive powers. The study was further extended to mitigate the harmonics by optimal placement of shunt capacitors (SCs) in all the test systems by incorporating MDM algorithm.