The demand of electricity globally led to the concept of renewable energy resources for power generation that are eco-friendly and freely available from nature. The solar photovoltaic systems and wind-based power generators are considered as primary renewable resources and are called as Distributed Generation units as they are scattered in nature. These are operated with bidirectional converters by providing auxiliary services at grid side and load side in either mode of microgrid operation. Besides, the DC power generation units’ integration gets converted into AC system by means of inverters. These types of systems not only increase voltage and current harmonics, power frequency deviations but also drive the distribution system to risky operating zone. This emphasizes the stipulation of advanced control schemes for microgrid architecture. Consequently, power electronic converters introduce harmonics in the system and affect the system performance. To report these expanded issues, the authors recognized an advanced custom power device entitled distributed power flow controller. The proposed hybrid solar-wind energy system is first studied with a distributed power-flow controller. Later the system is examined by replacing proportional integral controller with fuzzy logic controller (FLC) for shunt control of distributed power-flow controller. To validate the investigations, MATLAB/Simulink software is used.
Distributed generation strengthens distribution network reliability by placing generators close to load centers. The integration of electric vehicle charging stations (EVCSs) with PV systems mitigates the effects of EV charging burden. In this research, the objective is to combineEVCSs with distributed generation (DG) units in the Puducherry smart grid system to obtain optimized locations and enhance their reliability. To determine the right nodes for DGs and EVCSs in an uneven distribution network, the modified decision-making (MDM) algorithm and the model predictive control (MPC) approach are used. The Indian utility 29-node distribution network (IN29NDN), which is an unbalanced network, is used for testing. The effects of PV systems and EVCS units are studied in several settings and at various saturation levels. This study validates the correctness of its findings by evaluating the outcomes of proposed methodological approaches. DIgSILENT Power Factory is used to conduct the simulation experiments. The results show that optimizing the location of the DG unit and the size of the PV system can significantly minimize power losses and make a distribution network (DN) more reliable.
The work is presented in an organized manner. The novelty of the work may be highlighted in an effective way. Results may be presented clearly. Latest references are required. May add few applications as experimental setup is also presented.
The work is presented in an organized manner. The novelty of the work may be highlighted in an effective way. Results may be presented clearly. Latest references are required. May add few applications as experimental setup is also presented.
The work is presented in an organized way with clear explanation. May precise the theoretical content of basic concepts and elaborate the results in detail. References are outdated. Latest references are required to support the work. Please check the...