Renata Bende

Dr. Renata Bende

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Alexandru PopaAlexandru Popa
Alexandru Popa
FBFelix Bende
Felix Bende
Roxana SirliRoxana Sirli
Roxana Sirli
Alina PopescuAlina Popescu
Alina Popescu
VBVictor Bâldea
Victor Bâldea
Ioan SporeaIoan Sporea
Ioan Sporea
Non-alcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide. This study aimed to evaluate the performance of four ultrasound-based techniques for the non-invasive multiparametric (MPUS) assessment of liver fibrosis (LF), steatosis (HS), and inflammation in patients with NAFLD. We included 215 consecutive adult patients with NAFLD (mean age: 54.9 ± 11.7; 54.5% were male), in whom LF, HS, and viscosity were evaluated in the same session using four new ultrasound-based techniques embedded on the Aixplorer MACH 30 system: ShearWave Elastography (2D-SWE.PLUS), Sound Speed Plane-wave UltraSound (SSp.PLUS), Attenuation Plane-wave UltraSound (Att.PLUS), and Viscosity Plane-wave UltraSound (Vi.PLUS). Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) (FibroScan) were considered as control. All elastographic measurements were performed according to guidelines. Valid liver stiffness measurements (LSM) were obtained in 98.6% of patients by TE, in 95.8% of patients by 2D-SWE.PLUS/Vi.PLUS, and in 98.1% of patients by Att.PLUS/SSp.PLUS, respectively. Therefore, 204 subjects were included in the final analysis. A strong correlation between LSMs by 2D-SWE.PLUS and TE (r = 0.89) was found. The best 2D-SWE.PLUS cut-off value for the presence of significant fibrosis (F ≥ 2) was 7 kPa. Regarding steatosis, SSp.PLUS correlated better than Att.PLUS with CAP values: (r = −0.74) vs. (r = 0.45). The best SSp.PLUS cut-off value for predicting the presence of significant steatosis was 1524 m/s. The multivariate regression analysis showed that Vi.PLUS values were associated with BMI and LSM by 2D-SWE.PLUS. In conclusion, MPUS was useful for assessing fibrosis, steatosis, and inflammation in a single examination in patients with NAFLD.

18 February 2021 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
FBFelix Bende
Felix Bende
Ioan SporeaIoan Sporea
Ioan Sporea
Roxana SirliRoxana Sirli
Roxana Sirli
VBVictor Bâldea
Victor Bâldea
ALAlin Lazăr
Alin Lazăr
Alina PopescuAlina Popescu
Alina Popescu
Aim: Nonalcoholic Fatty Liver Disease (NAFLD) is increasing in frequency in daily practice and evaluation of liver steatosis, fibrosis and inflammation severity are essential for prognosis assessment. The aim was to evaluate the usefulnessof a new liver steatosis quantification system - Ultrasound-Guided Attenuation Parameter (UGAP) from General Electric Healthcare, using Controlled Attenuation Parameter (CAP) as the reference method.Material and method: 179 consecutive subjects, in whom liver steatosis was assessed in the same session using UGAP, implemented on LOGIQ E10 system (GE Healthcare), and CAP (FibroScan, EchoSens). To discriminate between steatosis stages by CAP, we used the cut-offs recommended by the manufacturer: S1 (mild) – 230 dB/m, S2 (moderate) – 275 dB/m, S3 (severe) – 300 dB/m.Results: We classified our cohort by means of CAP into the following groups: S0 (no steatosis): 48/176 (27.2%), S1 (mild): 56/176 (31.6%), S2 (moderate): 14/176 (7.3%) and S3 (severe): 59/176 (33.9%). The mean UGAP values increased with the steatosis grade and for each group were the following: S0: 198.3±25.7 dB/m, S1: 216.86±26.3 dB/m, S2: 237.79±26.3 dB/m, and S3: 270.8±31.62 dB/m respectively (p<0.001). A very good positive correlation was found between UGAP and CAP values (r=0.73, p<0.0001). The best cut-off values for predicting different grades of liver steatosis using CAP as the reference were: S1 - 192.5 dB/m (AUC 0.83); S2 – 231 dB/m (AUC 0.90) and S3 – 248 dB/m (AUC 0.91).Conclusion: UGAP seems to be a good method for liver steatosis quantification and correlates strongly with CAP values.

Verified
Journal Article
Open access
PDF file
FBFelix Bende
Felix Bende
Cristina TudoranCristina Tudoran
Cristina Tudoran
Ioan SporeaIoan Sporea
Ioan Sporea
FRFofiu Renata
Fofiu Renata
VBVictor Bâldea
Victor Bâldea
MTMariana Tudoran
Mariana Tudoran
(1) Background: Patients suffering from the novel coronavirus 2019 (COVID-19) disease could experience several extra-pulmonary involvements, including cardiovascular complications and liver injury. This study aims to evaluate the presence of cardiac and liver alterations in patients with post-acute COVID-19 syndrome using transthoracic echocardiography (TTE) and liver elastography (LE). (2) Methods: A total of 97 subjects recovering from COVID-19, attending the hospital’s specialized outpatient clinic for persisting symptoms at 3 to 11 weeks after the acute illness, were included in this study. They all had a basal COVID-19 assessment, and subsequently, a clinical evaluation, laboratory tests, TTE, and LE. (3) Results: considering the presence of pulmonary injury during COVID-19, patients were divided into two groups. Although none of them had altered systolic function, we evidenced pulmonary hypertension, diastolic dysfunction, increased liver stiffness, viscosity, and steatosis in around one-third of the patients, with significantly higher values in subjects with pulmonary injury compared to those without. (4) Conclusion: persisting symptoms characterizing the post-acute COVID-19 syndrome could be explained by residual cardiac and hepatic lesions, which were worse in more severe COVID-19 forms. These patients may be at risk of developing liver fibrosis and cardiac alterations and should be investigated in the first 12 weeks after the onset of the infection.

24 February 2020 in Medical Ultrasonography
Verified
Journal Article
Open access
PDF file
CFCamelia Foncea
Camelia Foncea
Alina PopescuAlina Popescu
Alina Popescu
RLRaluca Lupusoru
Raluca Lupusoru
FRFofiu Renata
Fofiu Renata
Roxana SirliRoxana Sirli
Roxana Sirli
Ioan SporeaIoan Sporea
Ioan Sporea
Aim: To evaluate the feasibility of two elastographic methods, point Shear Wave Elastography (pSWE) and two dimensional Shear Wave Elastography (2D-SWE), integrated in the same ultrasound machine, for liver fibrosis (LF) assessment, using Transient Elastography (TE) as the reference method.Material and methods: We included in the study 115 subjects in which LF was evaluated in the same session by TE (FibroScan, EchoSens), pSWE and 2D-SWE (Samsung-Medison RS85). Reliable liver stiffness (LS) measurements were defined: for TE the median value of 10 measurements with interquartile range (IQR/M)≤30%,while for pSWE and 2D-SWE the median value of 10 measurements, with a reliability measurement index (RMI)≥0.5 and IQR/M≤30%. For classification of LF severity we used TE as the reference method with the following cut-offs: F2≥7kPa, F3≥9.5kPa and F4≥12kPa.Results: Reliable measurements by TE were obtained in 98.2% of cases (113/115), by pSWE in 93.9% of cases (108/115) and by 2D-SWE in 92.1% of cases (106/115), so the final analysis included 101 patients. We divided the cohort into 3 groups: fibrosis 5.9 kPa [AUROC=0.95, 95%CI(0.89;0.98), p8 kPa [AUROC=0.98, 95%CI(0.94;0.99), p6.1 kPa [AUROC=0.93, 95%CI(0.86;0.97), p7.6 kPa [AUROC=0.98, 95%CI(0.93;0.99), p<0.0001, Se=100%, Sp=91.5%, PPV=72%, NPV=100%]. We observed strong correlations between LS values obtained by TE and 2D-SWE (r=0.85), between TE and pSWE (r=0.88) and between pSWE and 2D-SWE (r=0.90) (p=0.37), respectively. There were no significant differences between the mean values obtained by pSWE and 2D-SWE (p=0.96).Conclusion: The pSWE and 2D-SWE are feasible methods for assessing liver fibrosis, both techniques strongly correlating with TE results.

26 February 2023 in Biology
Verified
Journal Article
Open access
PDF file
Cristina TudoranCristina Tudoran
Cristina Tudoran
FRFofiu Renata
Fofiu Renata
FBFelix Bende
Felix Bende
CGCatalina Giurgi-Oncu
Catalina Giurgi-Oncu
AEAlexandra Enache
Alexandra Enache
MTMARIANA TUDORAN
MARIANA TUDORAN
(1) Background: Throughout the COVID-19 pandemic, it became obvious that individuals suffering with obesity, diabetes mellitus (T2DM), and metabolic syndrome (MS) frequently developed persisting cardiovascular complications, which were partially able to explain the onset of the long-COVID-19 syndrome. (2) Methods: Our aim was to document, by transthoracic echocardiography (TTE), the presence of cardiac alterations in 112 patients suffering from post-acute COVID-19 syndrome and T2DM, MS, and/or obesity, in comparison to 91 individuals without metabolic dysfunctions (MD); (3) Results: in patients with MD, TTE borderline/abnormal left (LVF) and/or right ventricular function (RVF), alongside diastolic dysfunction (DD), were more frequently evidenced, when compared to controls (p ˂ 0.001). Statistically significant associations between TTE parameters and the number of factors defining MS, the triglyceride-glucose (TyG) index, the severity of the SARS-CoV-2 infection, and the number of persisting symptoms (p ˂ 0.001) were noted. Significant predictive values for the initial C-reactive protein and TyG index levels, both for the initial and the 6-month follow-up levels of these TTE abnormalities (p ˂ 0.001), were highlighted by means of a multivariate regression analysis. (4) Conclusions: in diabetic patients with MS and/or obesity with comorbid post-acute COVID-19 syndrome, a comprehensive TTE delineates various cardiovascular alterations, when compared with controls. After 6 months, LVF and RVF appeared to normalize, however, the DD—although somewhat improved—did persist in approximately a quarter of patients with MD, possibly due to chronic myocardial changes.

5 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Cristina Mihaela RoiCristina Mihaela Roi
Cristina Mihaela Roi
Corina PaulCorina Paul
Corina Paul
ABAndreea Borlea
Andreea Borlea
FRFofiu Renata
Fofiu Renata
Florin BorcanFlorin Borcan
Florin Borcan
Dana StoianDana Stoian
Dana Stoian
Chronic autoimmune thyroiditis (CAT) is the most common thyroid disorder in the pediatric population. Ultrasound evaluation may suggest the diagnosis. Additionally, shear-wave elastography (SWE) proved to be a valuable additional diagnosis tool in adults with CAT by assessing thyroid stiffness (TS). This study aims to assess its use also in detecting children with CAT. The study group consisted of 50 children with confirmed diagnosis of CAT, who were compared to the control group, consisting of 50 children with no thyroid pathology and with an adult group of 50 subjects with CAT. The evaluation included, besides bioimmunochemical evaluation, also thyroid ultrasound evaluation and elastography measurements in the same session (Aixplorer Mach 30, Supersonic imagine, France). The mean TS values were significantly lower for children in the CAT group compared to adults with CAT (15.51 ± 4.76 kPa vs. 20.96 ± 6.31 kPa; p < 0.0001) and higher compared to the healthy aged matched controls (15.51 ± 4.76 kPa vs. 10.41 ± 2.01 kPa; p < 0.0001). SWE elastography definitely seems a promising technique in the evaluation of children with autoimmune thyroid pathology.