Egon Burian

Dr. Egon Burian


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2025 in Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
PDF file
AHAdib Al-Haj Husain
Adib Al-Haj Husain
VMVictor Mergen
Victor Mergen
SSSameena Sandhu
Sameena Sandhu
MWMaximilian Eberhard Hermann Wagner
Maximilian Eberhard Hermann Wagner
TDTristan Thorben Demmert
Tristan Thorben Demmert
HEHarald Essig
Harald Essig
Purpose: To assess postoperative fracture reduction and visualization of titanium-based and bioresorbable osteosynthesis materials in maxillofacial trauma surgery using ultra-high-resolution photon-counting detector computed tomography (PCD-CT) compared with cone-beam computed tomography (CBCT). Methods: Fractures were induced in six cadaveric pig mandibles at the angle, body, and parasymphysis and were stabilized using various titanium and bioresorbable plate systems. Specimens were scanned with CBCT and dose-matched PCD-CT in the ultra-high resolution mode, applying standard and low-dose protocols. Two observers assessed fracture reduction and implant delineation using a 5-point visual analog scale. Fracture gap and osteosynthesis materials were quantitatively measured and compared to ground-truth values. Descriptive statistics and inter-reader agreement (weighted κ) were calculated. Results: PCD-CT enabled excellent assessment of fracture reduction and visualization of osteosynthesis materials, with perfect inter-observer agreement (Median = 5, IQR, 5–5; κ = 1.0, p < 0.001), whereas low-dose CBCT showed reduced image quality and lower reproducibility (Median = 4, IQR, 4–4; κ = 0.92; p < 0.001). Bioresorbable plates were not directly visible using either scanner, but the associated screw drill holes were reliably delineated. PCD-CT achieved the smallest measurement deviations of fracture gap and osteosynthesis materials compared with ground truth, and with superior reproducibility (κ = 0.74–0.84; ICC = 0.95–0.99; all p < 0.001), outperforming CBCT across most parameters. Conclusions: Ultra-high resolution PCD-CT combines superior visualization and precise measurements compared with CBCT even at low radiation dose. With further clinical validation, these findings highlight PCD-CT’s strong potential for perioperative imaging in maxillofacial trauma, particularly benefiting younger patients who require repeated scans.

21 June 2025 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Open access
AHAdib Al-Haj Husain
Adib Al-Haj Husain
NLNynke Lie
Nynke Lie
SSSameena Sandhu
Sameena Sandhu
MWMaximilian Eberhard Hermann Wagner
Maximilian Eberhard Hermann Wagner
BSBernd Stadlinger
Bernd Stadlinger
HEHarald Essig
Harald Essig
This systematic review evaluates the current literature on state-of-the-art radiation-free MRI techniques for managing dental, oral, and maxillofacial trauma, comparing their diagnostic performance to conventional X-ray-based imaging. Two reviewers conducted an investigation using the PICOS search strategy across multiple databases, including MEDLINE, EMBASE, BIOSIS, Web of Science, Cochrane Library, LILACS, and BBO Dentistry. Twenty-nine studies were included: 12 on orbital trauma, 10 on condylar, subcondylar, or TMJ trauma, five on mandibular fractures, and one each on temporal bone and dental trauma. MRI was performed at post-traumatic, postoperative, or both stages. Despite variability in scan parameters, field strengths, and coil configurations, the results highlight MRI's growing potential in trauma assessment. CT-like and Black Bone MRI sequences enable simultaneous visualization of hard and soft tissues at trauma sites, providing diagnostic insights comparable to X-ray-based techniques. However, despite their superior soft-tissue assessment, they remain less effective at depicting intricate bony pathoanatomical conditions. This diagnostic approach can improve the long-term benefit-to-risk ratio, particularly for younger, radio-sensitive patients requiring repeated imaging and long-term follow-up. However, a modality- and protocol-oriented approach is essential to balance clinical conditions, radiation exposure, and diagnostic accuracy and efficiency, to ensure optimal patient outcomes in comprehensive trauma management.

28 July 2025 in Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
PDF file
AHAdib Al-Haj Husain
Adib Al-Haj Husain
PKPeter A.W.H. Keßler
Peter A.W.H. Keßler
NLNynke Lie
Nynke Lie
SDSamuel Drack
Samuel Drack
EBEgon Burian
Egon Burian
HEHarald Essig
Harald Essig
Purpose: To assess the effectiveness and feasibility of MRI-based delineation of fracture-prone regions in the oral and maxillofacial region using Black Bone and CT-like MRI protocols optimized for dentomaxillofacial imaging with a dedicated 15-channel mandibular coil. Methods: In this prospective study, healthy volunteers underwent 3T MRI using five protocols: DESS, SPACE STIR, SPACE SPAIR, T1-VIBE Dixon, and UTE. Eight trauma-prone regions, including the nasal septum, orbit, naso-orbito-ethmoidal (NOE) complex, zygomaticomaxillary complex, Le Fort regions, mandible, condyle, and dentoalveolar complex, were assessed. Image quality, artifacts, anatomical delineation, and bone-to-soft-tissue contrast were rated on a five-point Likert scale by three independent observers. Descriptive statistics and inter-rater agreement (intraclass correlation coefficients (ICCs)) were calculated. Results: Sixteen participants (37.2 ± 12.9 years; 12 males, 4 females) were included, resulting in 80 MRI volumes and 640 regions for evaluation. UTE and VIBE-DIXON sequences achieved the highest ratings for image quality, artifact susceptibility, and anatomical delineation across most fracture-prone regions (ICC: 0.793–1; all p < 0.001). UTE excelled in visualizing NOE and Le Fort regions, while VIBE-DIXON performed best in mandibular and orbital imaging. Bone-to-soft-tissue contrast was highest in UTE and VIBE-DIXON, highlighting their diagnostic potential in simultaneous soft and hard tissue imaging. Inter-rater agreement was consistently high (ICC: 0.772–0.976; all p < 0.001). Conclusion: Dedicated trauma-specific MRI protocols show promising potential as a radiation-free modality for maxillofacial trauma imaging, particularly in young adults and pediatric patients. The strengths of each protocol highlight the need for tailored sequence selection to optimize diagnostic accuracy and personalized care. Trial registration number : Swiss National Clinical Trials Portal: SNCTP000005246.

27 December 2025 in Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
PDF file
AHAdib Al-Haj Husain
Adib Al-Haj Husain
SSSameena Sandhu
Sameena Sandhu
MWMaximilian Eberhard Hermann Wagner
Maximilian Eberhard Hermann Wagner
EBEgon Burian
Egon Burian
NLNynke Lie
Nynke Lie
HEHarald Essig
Harald Essig
Purpose: To compare the diagnostic performance of computed tomography (CT) and magnetic resonance imaging (MRI) for surgically relevant parameters in mandibular trauma, evaluating five in-house-optimized MRI protocols with a dedicated 15-channel mandibular coil. Methods: Fifteen patients with 30 acute mandibular fractures underwent 3T MRI using five optimized protocols: UTE, StarVIBE, Dark Bone, DESS, and STIR. Three independent observers qualitatively rated image quality, fracture line visibility, cortical delineation, and bone-to-soft-tissue contrast on a five-point visual analog scale (5 = best, 1 = lowest). Quantitative analysis included measurement of the maximum distance of the fracture gap. Descriptive statistics and inter-observer agreement (Krippendorff’s α) were calculated. Results: CT enabled rapid and accurate fracture detection in all cases. Among MRI protocols, UTE (85% of fractures correctly identified and accurately diagnosed) and StarVIBE (75%) demonstrated the best diagnostic performance, with excellent fracture line visibility, sharp cortical delineation, and strong inter-observer agreement (α = 0.7–1.0.7.0). Dark Bone and DESS provided variable results, while STIR was the least suitable for fracture depiction despite good soft-tissue contrast. Quantitative assessment of fracture gap distance showed the highest accuracy with StarVIBE, demonstrating minimal deviation compared to CT (0.13–0.21 mm; p > 0.05). Conclusion: While CT remains the standard in emergency settings and for delineating complex osseous pathologies, MRI, combining CT-like and water-sensitive sequences, offers a promising radiation-free alternative for simultaneous visualization of hard and soft tissues. This approach may facilitate comprehensive radiation-free trauma evaluation, improve detection of concomitant injuries, and further support individualized clinical decision-making. Trial registration number: Swiss National Clinical Trials Portal: SNCTP000006343, ClinicalTrials.gov ID: NCT07012850.

10 October 2025 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
SSSameena Sandhu
Sameena Sandhu
AHAdib Al-Haj Husain
Adib Al-Haj Husain
VMVictor Mergen
Victor Mergen
TDTristan Thorben Demmert
Tristan Thorben Demmert
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
MWMaximilian Eberhard Hermann Wagner
Maximilian Eberhard Hermann Wagner
This ex vivo study aimed to compare photon-counting detector computed tomography (PCD-CT) and cone-beam computed tomography (CBCT) at matched standard- and low-dose radiation levels for evaluating perioperative imaging parameters relevant to mandibular fracture stabilization with osteosynthesis plates. Thirty-three osteosynthesis fixations were performed on six porcine mandibles with simulated fractures in the angle, body, and parasymphysis regions. Three types of plate systems (titanium microplates, titanium reconstruction plates, and bioresorbable copolymers) were used, each with varying plate thicknesses. Three blinded observers independently evaluated overall image quality, artifact severity, fracture line visibility, and visualization of peri‑osteosynthesis structures using 5-point visual analog scales. Descriptive statistics and inter-reader agreement (Krippendorff's alpha) were calculated. PCD-CT consistently demonstrated superior overall image quality, reduced artifact severity, and better visualization of fracture lines and peri‑osteosynthetic structures compared to CBCT, particularly using low-dose settings. Bioresorbable plates caused no artifacts in either modality. Inter-observer agreement was good to excellent across all parameters (Krippendorff's α = 0.72-1.0). PCD-CT outperformed CBCT in visualizing mandibular fracture stabilization with various osteosynthesis materials, particularly under low-dose conditions, demonstrating high reliability among observers. These findings indicate that PCD-CT may offer diagnostic advantages in the perioperative setting; however, further clinical studies are needed to confirm its role in imaging oral and maxillofacial trauma.

6 August 2025 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
EBEgon Burian
Egon Burian
NSNico Sollmann
Nico Sollmann
JCJulio Carballido-Gamio
Julio Carballido-Gamio
Fragility fractures represent a significant global health burden and can arise from osteoporosis (1). While areal bone mineral density (aBMD) derived from dual-energy X-ray absorptiometry (DXA) has long been the diagnostic standard, approximately 50% of fractures occur in individuals with aBMD above the osteoporotic threshold, underscoring limitations of DXA-derived aBMD in capturing the multifaceted nature of bone fragility (2)(3)(4)(5). This necessitates a shift towards comprehensive imaging techniques and/or parameters that offer deeper insights into bone quality such as microarchitecture and biomechanical factors. This research topic explored recent advancements, persistent challenges, and future directions in this evolving field.Conventional DXA provides a two-dimensional (2D) projection, simplifying bone geometry and material properties, but with measurements confounded by bone size (2). However, extracting sophisticated structural information from existing DXA scans could enhance its utility. The "Minimal Model" (MM) of hip structure, derived from DXA Hip Structural Analysis (HSA) variables like Femoral Neck Width (FNW), Sigma, and Delta, offers crucial biomechanical insights beyond simple aBMD. Zhao et al. demonstrated that the MM significantly improved hip fracture discrimination (area under the curve [AUC] = 0.838) compared to BMD alone (AUC = 0.781) in Chinese adults, with increases in FNW, Sigma, and Delta independently associated with higher hip fracture risk (6). This study indicated that detailed structural geometry, even from 2D imaging, might provide superior predictive power.Quantitative computed tomography (QCT) offers three-dimensional (3D) volumetric imaging, enabling separate analysis of cortical and trabecular bone and measuring volumetric BMD (vBMD) without projection errors (2,4). Furthermore, QCT enables assessments of bone shape and cortical bone thickness, and estimates of bone strength through finite element analysis (FEA) (7). However, the spatial resolution of QCT scans at the proximal femur and spine is not enough to visualize trabecular bone microarchitecture and its higher radiation dose and required FEA expertise limit its routine clinical use. Leveraging routine CT scans, Hounsfield Units (HU) are emerging as a valuable metric for osteoporosis assessments. Chen et al. showed that anterior column HU values were significantly lower in osteoporotic vertebral compression fractures (OVCFs) and correlated strongly with DXA T-scores (r = 0.643) and aBMD (r = 0.656) (8). Crucially, anterior column HU demonstrated the highest correlation with vertebral compression degrees (r=0.727) and superior predictive ability for severe OVCFs (grade 3), with an optimal cutoff of 59.07 HU (AUC = 0.913) (8). This opportunistic approach provided a localized bone quality assessment that could directly inform clinical decisions like short-term absolute bed rest post-fracture. Chemical shift encoding-based water-fat separation MRI (CSE-MRI) is a non-invasive, radiation-free tool for assessing bone and muscle composition (5, 9, 10). Stohldreier et al. investigated 6-month changes in proton density fat fraction (PDFF) and T2* of paraspinal muscles (PSM) and vertebral bone marrow (VBM; T11-L4) as predictive biomarkers for incidental VCFs (11). They found that PDFF significantly increased in both PSM and VBM in patients who subsequently developed VCFs, even when opportunistic CT-based BMD remained unchanged. This suggests fatty degeneration is a crucial, early biomarker for bone fragility, challenging sole reliance on BMD Decreasing PSM T2* was also identified as a risk factor (11). This innovative MRI application shifts assessment from purely structural to detecting metabolic and compositional changes, potentially enabling earlier risk stratification.Image-based biomechanical approaches, particularly FEA, aim to directly assess bone strength by simulating fracture-inducing forces. FE models, constructed from DXA or QCT data, estimate stress and strain distributions via computational modeling to predict bone strength and fracture loads (12,13). In this regard, DXA-based FEA is accessible and comes at low radiation exposure, but relies on simplified 2D geometry. QCT-based FEA offers detailed 3D insights but incurs higher costs and radiation as well as expertise. Despite theoretical superiority, biomechanical models still face significant barriers to clinical integration. Key challenges include: (1) accurate material property characterization: current imaging struggles to quantify non-mineral components (collagen, water) crucial for bone toughness and viscoelasticity, leading to incomplete material data for FE models ( 14); (2) modeling bone anisotropy: most FE models use simplified isotropic assumptions, overlooking bone's directional strength variations, which limits accuracy in simulating multi-directional fall forces (14); and (3) realistic fall simulations: real-world falls are unpredictable, influenced by random triggers and complex individual-specific muscle reflexes that are difficult to accurately replicate in simulations (14). These fundamental scientific and engineering hurdles necessitate continued research in advanced imaging, material science, and computational modeling for FEA to reach its full clinical potential.Fracture risk extends beyond bone integrity, involving soft tissues and systemic health. Ahmed Mohamed et al. conducted a meta-analysis that revealed that preoperative thoracolumbar fascia injury (TLFI), diagnosed by MRI, may be a frequently overlooked complication in OVCFs (28% incidence) that significantly increases residual back pain post-percutaneous vertebral augmentation (odds ratio = 4.79) (15). This highlights the need for a holistic assessment, including soft tissue integrity, for comprehensive pain management.Furthermore, bone fragility is intertwined with systemic diseases. Jin et al. demonstrated that in patients with Parkinson's disease (PD),...