11 October 2025 in Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
PDF file
AHAdib Al-Haj Husain
Adib Al-Haj Husain
VMVictor Mergen
Victor Mergen
SSSameena Sandhu
Sameena Sandhu
MWMaximilian Eberhard Hermann Wagner
Maximilian Eberhard Hermann Wagner
TDTristan Thorben Demmert
Tristan Thorben Demmert
HEHarald Essig
Harald Essig
Purpose: To assess postoperative fracture reduction and visualization of titanium-based and bioresorbable osteosynthesis materials in maxillofacial trauma surgery using ultra-high-resolution photon-counting detector computed tomography (PCD-CT) compared with cone-beam computed tomography (CBCT). Methods: Fractures were induced in six cadaveric pig mandibles at the angle, body, and parasymphysis and were stabilized using various titanium and bioresorbable plate systems. Specimens were scanned with CBCT and dose-matched PCD-CT in the ultra-high resolution mode, applying standard and low-dose protocols. Two observers assessed fracture reduction and implant delineation using a 5-point visual analog scale. Fracture gap and osteosynthesis materials were quantitatively measured and compared to ground-truth values. Descriptive statistics and inter-reader agreement (weighted κ) were calculated. Results: PCD-CT enabled excellent assessment of fracture reduction and visualization of osteosynthesis materials, with perfect inter-observer agreement (Median = 5, IQR, 5–5; κ = 1.0, p < 0.001), whereas low-dose CBCT showed reduced image quality and lower reproducibility (Median = 4, IQR, 4–4; κ = 0.92; p < 0.001). Bioresorbable plates were not directly visible using either scanner, but the associated screw drill holes were reliably delineated. PCD-CT achieved the smallest measurement deviations of fracture gap and osteosynthesis materials compared with ground truth, and with superior reproducibility (κ = 0.74–0.84; ICC = 0.95–0.99; all p < 0.001), outperforming CBCT across most parameters. Conclusions: Ultra-high resolution PCD-CT combines superior visualization and precise measurements compared with CBCT even at low radiation dose. With further clinical validation, these findings highlight PCD-CT’s strong potential for perioperative imaging in maxillofacial trauma, particularly benefiting younger patients who require repeated scans.

22 August 2025 in Investigative Radiology
Verified
Journal Article
Open access
Konstantin KlambauerKonstantin Klambauer
Konstantin Klambauer
SBSilvan Daniel Burger
Silvan Daniel Burger
TDTristan Thorben Demmert
Tristan Thorben Demmert
VMVictor Mergen
Victor Mergen
LMLukas Jakob Moser
Lukas Jakob Moser
BSBernhard Schmidt
Bernhard Schmidt
Objectives: The aim of this study was to evaluate the feasibility and reproducibility of a novel deep learning (DL)-based coronary plaque quantification tool with automatic case preparation in patients undergoing ultra-high resolution (UHR) photon-counting detector CT coronary angiography (CCTA), and to assess the influence of temporal resolution on plaque quantification. Materials and Methods: In this retrospective single-center study, 45 patients undergoing clinically indicated UHR CCTA were included. In each scan, 2 image data sets were reconstructed: one in the dual-source mode with 66 ms temporal resolution and one simulating a single-source mode with 125 ms temporal resolution. A novel, DL-based algorithm for fully automated coronary segmentation and intensity-based plaque quantification was applied to both data sets in each patient. Plaque volume quantification was performed at the vessel-level for the entire left anterior descending artery (LAD), left circumflex artery (CX), and right coronary artery (RCA), as well as at the lesion-level for the largest coronary plaque in each vessel. Diameter stenosis grade was quantified for the coronary lesion with the greatest longitudinal extent in each vessel. To assess reproducibility, the algorithm was rerun 3 times in 10 randomly selected patients, and all outputs were visually reviewed and confirmed by an expert reader. Paired Wilcoxon signed-rank tests with Benjamini-Hochberg correction were used for statistical comparisons. Results: One hundred nineteen out of 135 (88.1%) coronary arteries showed atherosclerotic plaques and were included in the analysis. In the reproducibility analysis, repeated runs of the algorithm yielded identical results across all plaque and lumen measurements ( P > 0.999). All outputs were confirmed to be anatomically correct, visually consistent, and did not require manual correction. At the vessel level, total plaque volumes were higher in the 125 ms reconstructions compared with the 66 ms reconstructions in 28 of 45 patients (62%), with both calcified and noncalcified plaque volumes being higher in 32 (71%) and 28 (62%) patients, respectively. Total plaque volumes in the LAD, CX, and RCA were significantly higher in the 125 ms reconstructions (681.3 vs. 647.8 mm 3 , P < 0.05). At the lesion level, total plaque volumes were higher in the 125 ms reconstructions in 44 of 45 patients (98%; 447.3 vs. 414.9 mm 3 , P < 0.001), with both calcified and noncalcified plaque volumes being higher in 42 of 45 patients (93%). The median diameter stenosis grades for all vessels were significantly higher in the 125 ms reconstructions (35.4% vs. 28.1%, P < 0.01). Conclusions: This study evaluated a novel DL-based tool with automatic case preparation for quantitative coronary plaque in UHR CCTA data sets. The algorithm was technically robust and reproducible, delivering anatomically consistent outputs not requiring manual correction. Reconstructions with lower temporal resolution (125 ms) systematically overestimated plaque burden compared with higher temporal resolution (66 ms), underscoring that protocol standardization is essential for reliable DL-based plaque quantification.

10 October 2025 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Open access
SSSameena Sandhu
Sameena Sandhu
AHAdib Al-Haj Husain
Adib Al-Haj Husain
VMVictor Mergen
Victor Mergen
TDTristan Thorben Demmert
Tristan Thorben Demmert
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
MWMaximilian Eberhard Hermann Wagner
Maximilian Eberhard Hermann Wagner
This ex vivo study aimed to compare photon-counting detector computed tomography (PCD-CT) and cone-beam computed tomography (CBCT) at matched standard- and low-dose radiation levels for evaluating perioperative imaging parameters relevant to mandibular fracture stabilization with osteosynthesis plates. Thirty-three osteosynthesis fixations were performed on six porcine mandibles with simulated fractures in the angle, body, and parasymphysis regions. Three types of plate systems (titanium microplates, titanium reconstruction plates, and bioresorbable copolymers) were used, each with varying plate thicknesses. Three blinded observers independently evaluated overall image quality, artifact severity, fracture line visibility, and visualization of peri‑osteosynthesis structures using 5-point visual analog scales. Descriptive statistics and inter-reader agreement (Krippendorff's alpha) were calculated. PCD-CT consistently demonstrated superior overall image quality, reduced artifact severity, and better visualization of fracture lines and peri‑osteosynthetic structures compared to CBCT, particularly using low-dose settings. Bioresorbable plates caused no artifacts in either modality. Inter-observer agreement was good to excellent across all parameters (Krippendorff's α = 0.72-1.0). PCD-CT outperformed CBCT in visualizing mandibular fracture stabilization with various osteosynthesis materials, particularly under low-dose conditions, demonstrating high reliability among observers. These findings indicate that PCD-CT may offer diagnostic advantages in the perioperative setting; however, further clinical studies are needed to confirm its role in imaging oral and maxillofacial trauma.

1 December 2025 in Investigative Radiology
Verified
Journal Article
Open access
TDTristan Thorben Demmert
Tristan Thorben Demmert
Konstantin KlambauerKonstantin Klambauer
Konstantin Klambauer
BSBernhard Schmidt
Bernhard Schmidt
VMVictor Mergen
Victor Mergen
LMLukas J. Moser
Lukas J. Moser
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Background: Blooming artifacts from calcified plaques can obscure the vessel lumen, leading to overestimation of stenosis severity. Spectral coronary angiography with photon-counting detector CT (PCD-CT) provides virtual monoenergetic images (VMIs) for coronary artery disease assessment. While VMIs at high VMI energy levels reduce calcium blooming, iodine contrast is diminished, limiting diagnostic value. This study evaluated whether contrast media with an atomic number higher than iodine (high-Z) preserve vascular contrast using high VMI energy levels, thereby improving the accuracy of stenosis quantification. Methods: A phantom with 4 and 6 mm diameter rods to mimic small diameter vessels containing eccentric calcified plaques causing 25%, 50%, and 75% diameter stenoses was scanned with a dual-source PCD-CT system. Five different contrast media, including iodine, tungsten, holmium, hafnium, and bismuth, were tested. VMIs were reconstructed from 40 to 190 keV in 1-keV steps. Vessel attenuation, contrast-to-noise ratio (CNR), and stenoses were measured. Qualitative assessment of image quality was performed. Results: Iodine attenuation was high at lower VMI energy levels and dropped below 250 HU at >100 keV. Tungsten, holmium, hafnium, and bismuth maintained >250 HU attenuation throughout the entire energy range. Vessel CNR of iodine was high at lower and decreased at higher VMI energy levels, similar to the CNR of holmium and bismuth, though to a lesser extent. In distinction, CNRs of tungsten and hafnium were lower at lower VMI energy levels and increased to a relatively constant level at higher keV. Tungsten CNR increased with energy, approaching ~40 at high keV. Across all contrast media and stenosis degrees, stenoses were overestimated on low VMI energy levels (24% to 32.5% at 40 keV), while the degree of overestimation decreased at higher VMI energy levels (0% to 13.5% at 190 keV). At 190 keV, tungsten, hafnium, and bismuth showed ≤2.5% stenosis overestimation, compared with iodine (10% to 13.5%). Image quality varied between contrast media and energy levels: new very high-Z contrast media achieved higher scores, while iodine peaked at lower keV (55 to 70 keV) and, due to loss of contrast at higher energies, received the lowest overall scores. Conclusions: As compared with iodine, very high-Z contrast media enable superior lumen definition and more accurate stenosis assessment, also at high VMI energy levels, which minimize calcium blooming.

29 January 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AHAdib Al-Haj Husain
Adib Al-Haj Husain
VMVictor Mergen
Victor Mergen
NHNadin Al-Haj Husain
Nadin Al-Haj Husain
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
TDTristan Thorben Demmert
Tristan Thorben Demmert
BSBernd Stadlinger
Bernd Stadlinger
To assess the diagnostic performance of photon-counting detector computed tomography (PCD-CT) and cone-beam computed tomography (CBCT) at dose-matched radi

12 October 2026 in Investigative Radiology
Verified
Journal Article
Open access
DZDaniel Zedler
Daniel Zedler
TDTristan Thorben Demmert
Tristan Thorben Demmert
ARAndré Ritter
André Ritter
TAThomas Allmendinger
Thomas Allmendinger
BSBernhard Schmidt
Bernhard Schmidt
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Objective: Motion artifacts remain a limitation of cardiac CT when assessing both native and prosthetic heart valves, particularly during phases of rapid motion. This may lead to reduced image quality, potentially impairing the evaluation of valvular movement and pathology. The purpose of this study was to evaluate whether a novel reconstruction-based motion correction algorithm improves image quality and reduces motion artifacts of native and prosthetic heart valves compared with standard reconstructions in photon-counting detector CT (PCD-CT). Materials and Methods: In this retrospective single-center study, 57 patients [21 women; median age, 71 (interquartile range, 57 to 78 y)] who underwent clinically indicated 4D cardiac CT for suspected native and prosthetic valvular disease were included. Images were acquired using retrospectively electrocardiography (ECG)-gated spiral dual-source PCD-CT without ECG-pulsing. Images were reconstructed in 10% steps throughout the RR-interval using both standard (TrueStack) and an otherwise identical reconstruction using the novel motion correction algorithm (ZeeFreePlus). Subjective image quality and motion artifacts were independently assessed by 2 blinded, experienced readers using a 4-point visual analog scale for 3 categories: valve frame/annulus, valve leaflets, and valvular pathology. Objective analysis included quantification of the volume of artifacts throughout the cardiac cycle. Results: A total of 68 valves were evaluated, including 57 prosthetic valves (22 transcatheter aortic valve replacements and 19 surgical valves, 11 mitral valves, and 5 tricuspid valve interventions) and 11 native valves. Valvular pathology was present in 29 cases, with the most prevalent being hypoattenuated leaflet thickening in 14/29 (48%). Motion-corrected reconstructions significantly improved image quality and reduced motion artifacts across all cardiac phases and all categories (all, P <0.001). The largest improvements were observed during systole, particularly at 10% of the RR-interval, with significantly greater gains than during diastole ( P <0.05). Improvements were consistent across aortic and atrioventricular prosthetic valves and translated into improved visualization of valvular pathology ( P <0.001). Objective quantitative analysis corroborated the subjective image quality findings by demonstrating reductions in the volumes of motion-induced artifacts when using the algorithm ( P <0.001). Conclusions: A novel motion correction algorithm substantially reduced motion artifacts and improved image quality in both native and prosthetic heart valve imaging with PCD-CT, with the largest improvements in systole. These benefits resulted in enhanced visualization of valvular pathology, potentially reinforcing the growing clinical role of cardiac CT for the assessment of valve disease.