Christopher Simmons

Dr. Christopher Simmons


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
GBGokul Balagopal
Gokul Balagopal
LWLakitha Omal Harindha Wijeratne
Lakitha Omal Harindha Wijeratne
JWJohn Waczak
John Waczak
PDPrabuddha Madusanka Hathurusinghe Dewage
Prabuddha Madusanka Hathurusinghe Dewage
MIMazhar Iqbal
Mazhar Iqbal
David J LaryDavid J Lary
David J Lary
This study calibrates an affordable, solar-powered LoRaWAN air quality monitoring prototype using the research-grade Palas Fidas Frog sensor. Motivated by the need for sustainable air quality monitoring in smart city initiatives, this work integrates low-cost, self-sustaining sensors with research-grade instruments, creating a cost-effective hybrid network that enhances both spatial coverage and measurement accuracy. To improve calibration precision, the study leverages the Super Learner machine learning technique, which optimally combines multiple models to achieve robust PM (Particulate Matter) monitoring in low-resource settings. Data was collected by co-locating the Palas sensor and LoRaWAN devices under various climatic conditions to ensure reliability. The LoRaWAN monitor measures PM concentrations alongside meteorological parameters such as temperature, pressure, and humidity. The collected data were calibrated against precise PM concentrations and particle count densities from the Palas sensor. Various regression models were evaluated, with the stacking-based Super Learner model outperforming traditional approaches, achieving an average test R2 value of 0.96 across all target variables, including 0.99 for PM2.5 and 0.91 for PM10.0. This study presents a novel approach by integrating Super Learner-based calibration with LoRaWAN technology, offering a scalable solution for low-cost, high-accuracy air quality monitoring. The findings demonstrate the feasibility of deploying these sensors in urban areas such as the Dallas-Fort Worth metroplex, providing a valuable tool for researchers and policymakers to address air pollution challenges effectively.

26 November 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XYXiaohe Yu
Xiaohe Yu
David J LaryDavid J Lary
David J Lary
CSChristopher Simmons
Christopher Simmons
In this study, we present a nationwide machine learning model for hourly PM2.5 estimation for the continental United States (US) using high temporal resolution Geostationary Operational Environmental Satellites (GOES-16) Aerosol Optical Depth (AOD) data, meteorological variables from the European Center for Medium Range Weather Forecasting (ECMWF) and ancillary data collected between May 2017 and December 2020. A model sensitivity analysis was conducted on predictor variables to determine the optimal model. It turns out that GOES16 AOD, variables from ECMWF, and ancillary data are effective variables in PM2.5 estimation and historical reconstruction, which achieves an average mean absolute error (MAE) of 3.0 μg/m3, and a root mean square error (RMSE) of 5.8 μg/m3. This study also found that the model performance as well as the site measured PM2.5 concentrations demonstrate strong spatial and temporal patterns. Specifically, in the temporal scale, the model performed best between 8:00 p.m. and 11:00 p.m. (UTC TIME) and had the highest coefficient of determination (R2) in Autumn and the lowest MAE and RMSE in Spring. In the spatial scale, the analysis results based on ancillary data show that the R2 scores correlate positively with the mean measured PM2.5 concentration at monitoring sites. Mean measured PM2.5 concentrations are positively correlated with population density and negatively correlated with elevation. Water, forests, and wetlands are associated with low PM2.5 concentrations, whereas developed, cultivated crops, shrubs, and grass are associated with high PM2.5 concentrations. In addition, the reconstructed PM2.5 surfaces serve as an important data source for pollution event tracking and PM2.5 analysis. For this purpose, from May 2017 to December 2020, hourly PM2.5 estimates were made for 10 km by 10 km and the PM2.5 estimates from August through November 2020 during the period of California Santa Clara Unite (SCU) Lightning Complex fires are presented. Based on the quantitative and visualization results, this study reveals that a number of large wildfires in California had a profound impact on the value and spatial-temporal distributions of PM2.5 concentrations.

21 January 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XYXiaohe Yu
Xiaohe Yu
David J LaryDavid J Lary
David J Lary
CSChristopher Simmons
Christopher Simmons
LWLakitha Omal Harindha Wijeratne
Lakitha Omal Harindha Wijeratne
PM2.5, a type of fine particulate with a diameter equal to or less than 2.5 micrometers, has been identified as a major source of air pollution, and is associated with many health issues. Research on utilizing various data sources, such as remote sensing and in situ sensors, for PM2.5 concentrations modeling remains a hot topic. In this study, the Next Generation Weather Radar (NEXRAD) is used as a supplementary weather data source, along with European Centre for Medium-Range Weather Forecasts (ECMWF), solar angles, and Geostationary Operational Environmental Satellite (GOES16) Aerosol Optical Depth (AOD) to model high spatial-temporal PM2.5 concentrations. PM2.5 concentrations as well as in situ weather condition variables are collected from the 31 sensors that are deployed in the Dallas Metropolitan area. Four machine learning models with different predictor variables are developed based on an ensemble approach. Since in situ weather observations are not widely available, ECMWF is used as an alternative data source for weather conditions in studies. Hence, the four established models are compared in three groups. Both models in this first group use weather variables collected from deployed sensors, but one uses NEXRAD and the other does not. In the second group, the two models use weather variables retrieved from ECMWF, one using NEXRAD and one without. In the third group, one model uses weather variables from ECMWF, and the other uses in situ weather variables, both without NEXRAD. The first two environmental groups investigate how NEXRAD can enhance model performances with weather variables collected from in situ observations and ECMWF, respectively. The third group explores how effective using ECMWF as an alternative source of weather conditions. Based on the results, the incorporation of NEXRAD achieves an R2 score of 0.86 and 0.83 for groups 1 and 2, respectively, for an improvement of 2.8% and 9.6% over those models without NEXRAD. For group three, the use of ECMWF as an alternative source of in situ weather observations results in a 0.13 R2 drop. For PM2.5 estimation, weather variables including precipitation, temperature, pressure, and surface pressure from ECMWF and deployed sensors, as well as NEXRAD velocity, are shown to be significant factors.

4 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GBGokul Balagopal
Gokul Balagopal
LWLakitha Omal Harindha Wijeratne
Lakitha Omal Harindha Wijeratne
JWJohn Waczak
John Waczak
PDPrabuddha Madusanka Hathurusinghe Dewage
Prabuddha Madusanka Hathurusinghe Dewage
MIMazhar Iqbal
Mazhar Iqbal
David J LaryDavid J Lary
David J Lary
This study calibrates an affordable, solar-powered LoRaWAN air quality monitoring prototype using the research-grade Palas Fidas Frog sensor. By leveraging the Super Learner machine learning technique, it develops cost-effective sensors for accurate PM (Particulate Matter) monitoring in low-resource settings. Data was collected by co-locating the Palas sensor and LoRaWAN devices under various climatic conditions over multiple days to ensure reliable calibration. The LoRaWAN air quality monitor integrates sensors that measure PM concentrations and meteorological parameters, including temperature, pressure, and humidity. The collected data were calibrated using precise PM concentrations and particle count density measured by the Palas sensor. Various regression models were evaluated, with the stacking model (Super Learner) demonstrating superior performance. By combining simple and complex models, the stacking model achieved the most accurate predictions, with an average test R2 value of 0.96 across all target variables. Specifically, it achieved R2 values of 0.99 for PM2.5 and 0.91 for PM10.0, demonstrating near-research-grade accuracy and underscoring the robustness of the calibration. This study offers a practical and scalable solution for cost-effective air quality monitoring, with significant potential for deployment in the Dallas-Fort Worth metroplex and similar urban areas.

3 March 2025 in Air
Verified
Journal Article
Open access
PDF file
GBGokul Balagopal
Gokul Balagopal
LWLakitha Omal Harindha Wijeratne
Lakitha Omal Harindha Wijeratne
JWJohn Waczak
John Waczak
PDPrabuddha Madusanka Hathurusinghe Dewage
Prabuddha Madusanka Hathurusinghe Dewage
MIMazhar Iqbal
Mazhar Iqbal
David J LaryDavid J Lary
David J Lary
This study aims to determine the optimal frequency for monitoring airborne pollutants in densely populated urban areas to effectively capture their temporal variations. While environmental organizations worldwide typically update air quality data hourly, there is no global consensus on the ideal monitoring frequency to adequately resolve pollutant (particulate matter) time series. By applying temporal variogram analysis to particulate matter (PM) data over time, we identified specific measurement intervals that accurately reflect fluctuations in pollution levels. Using January 2023 air quality data from the Joppa neighborhood of Dallas, Texas, USA, temporal variogram analysis was conducted on three distinct days with varying PM2.5 (particulate matter of size ≤ 2.5 μm in diameter) pollution levels. For the most polluted day, the optimal sampling interval for PM2.5 was determined to be 12.25 s. This analysis shows that highly polluted days are associated with shorter sampling intervals, highlighting the need for highly granular observations to accurately capture variations in PM levels. Using the variogram analysis results from the most polluted day, we trained machine learning models that can predict the sampling time using meteorological parameters. Feature importance analysis revealed that humidity, temperature, and wind speed could significantly impact the measurement time for PM2.5. The study also extends to the other size fractions measured by the air quality monitor. Our findings highlight how local conditions influence the frequency required to reliably track changes in air quality.

15 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
LWLakitha Omal Harindha Wijeratne
Lakitha Omal Harindha Wijeratne
DKDaniel Kiv
Daniel Kiv
JWJohn Waczak
John Waczak
PDPrabuddha Madusanka Hathurusinghe Dewage
Prabuddha Madusanka Hathurusinghe Dewage
GBGokul Balagopal
Gokul Balagopal
David J LaryDavid J Lary
David J Lary
The goal of this study is to describe a design architecture for a self-powered IoT (Internet of Things) sensor network that is currently being deployed at various locations throughout the Dallas-Fort Worth metroplex to measure and report on Particulate Matter (PM) concentrations. This system leverages diverse low-cost PM sensors, enhanced by machine learning for sensor calibration, with LoRaWAN connectivity for long-range data transmission. Sensors are GPS-enabled, allowing precise geospatial mapping of collected data, which can be integrated with urban air quality forecasting models and operational forecasting systems. To achieve energy self-sufficiency, the system uses a small-scale solar-powered solution, allowing it to operate independently from the grid, making it both cost-effective and suitable for remote locations. This novel approach leverages multiple operational modes based on power availability to optimize energy efficiency and prevent downtime. By dynamically adjusting system behavior according to power conditions, it ensures continuous operation while conserving energy during periods of reduced supply. This innovative strategy significantly enhances performance and resource management, improving system reliability and sustainability. This IoT network provides localized real-time air quality data, which has significant public health benefits, especially for vulnerable populations in densely populated urban environments. The project demonstrates the synergy between IoT sensor data, machine learning-enhanced calibration, and forecasting methods, contributing to scientific understanding of microenvironments, human exposure, and public health impacts of urban air quality. In addition, this study emphasizes open source design principles, promoting transparency, data quality, and reproducibility by exploring cost-effective sensor calibration techniques and adhering to open data standards. The next iteration of the sensors will include edge processing for short-term air quality forecasts.