We describe a novel experimental device, the VaMa (Vatavuk and Marić) artificial intraocular lens (IOL) capsule, and a method that enables all IOL types to be implanted in the bag. We present the application of the device and the procedure in patients with aphakia and native capsule damage and without efficient capsular support. The VaMa device and the method facilitate IOL exchange due to refractive errors and, in the case of their invention, the implementation of superior IOLs in the future. The postoperative results after the implantation of the VaMa capsule along with IOLs in three patients are promising, with significant visual improvement and without adverse events 7 to 10 months postoperatively.
The aim of this study was to explore diplopia as a symptom of undetected COVID-19 infection or as a possible side effect of COVID-19 vaccination. We examined 380 patients with diplopia admitted to the Department of Ophthalmology of the University Hospital Centre Sestre milosrdnice in Zagreb, Croatia, from July 2020 to June 2022. After excluding patients with confirmed organic underlying diplopia causes or monocular diplopia, we linked the patient information with the national COVID-19 and vaccination registries. Among the 91 patients included in this study, previously undetected COVID-19 infection as the possible cause of diplopia was confirmed in five of them (5.5%). An additional nine patients (9.9%) were vaccinated within one month from the onset of their symptoms, while the remaining 77 had neither and were therefore considered as controls. The breakdown according to the mechanism of diplopia showed no substantial difference between the vaccinated patients and the controls. We detected marginally insignificant excess abducens nerve affection in the COVID-positive group compared with that in the controls (p = 0.051). Post-vaccination diplopia was equally common in patients who received vector-based or RNA-based vaccines (21.4 vs. 16.7%; p = 0.694). COVID-19 testing should be performed for all cases of otherwise unexplained diplopia. The risk of post-vaccination diplopia was similar in both types of vaccines administered, suggesting a lack of evidence linking specific vaccine types to diplopia.
Purpose: To describe a slit-modified 23-gauge infusion trocar designed to enable early postoperative hypotony-free sclerotomy closure by allowing scleral suturing prior to complete trocar removal, and to report initial clinical outcomes in eyes with proliferative diabetic retinopathy with or without vitreous hemorrhage (PDR+H and PDR). Methods: A standard 23-gauge metallic (titanium) trocar was modified by creating a longitudinal slit that permits passage of a suture needle while the trocar remains partially engaged within the scleral tunnel. At the end of pars plana vitrectomy, a transscleral suture was placed through the slit with the knot prepared prior to trocar removal, followed by simultaneous trocar extraction and suture tightening. Eighteen consecutive patients undergoing vitrectomy for PDR (14 with vitreous hemorrhage [PDR+H], 4 without) were included. Intraocular pressure (IOP) was recorded preoperatively, immediately after sclerotomy closure (postoperative baseline), and at 8 and 24 hours postoperatively. Primary outcomes were postoperative IOP stability and wound leakage. Secondary outcomes included early hypotony, postoperative hemorrhage, choroidal effusion, and the need for additional suturing. Results: All procedures were completed without intraoperative complications. Mean IOP was 14.83 ± 2.50 mmHg preoperatively, 13.33 ± 1.53 mmHg immediately after closure, 14.17 ± 3.01 mmHg at 8 hours, and 15.17 ± 1.79 mmHg at 24 hours. No cases of wound leakage or early postoperative hypotony were observed in either subgroup. One eye exhibited a transient IOP increase at 8 hours; no choroidal effusion, postoperative hemorrhage, or need for secondary suturing occurred. Endotamponade consisted of balanced salt solution (BSS) in 8 eyes, SF6 in 7 eyes, silicone oil in 2 eyes, and air in 1 eye. Conclusions: The slit-modified infusion trocar enables secure, hypotony-free closure of the infusion sclerotomy by eliminating the open-wound interval during trocar removal. This simple biomedical device modification provides stable early postoperative IOP across different tamponade agents and appears safe and feasible in high-risk eyes with PDR.