Armin Kasumovic

Dr. Armin Kasumovic

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
IKInes Matoc Kasumovic
Ines Matoc Kasumovic
KKKim Kasa
Kim Kasa
AKArmin Kasumovic
Armin Kasumovic
APAnte Prpić
Ante Prpić
AVAnte Vukojević
Ante Vukojević
ZVZoran Vatavuk
Zoran Vatavuk
The aim of this study is to assess the effectiveness of a 12-week doxycycline treatment for thyroid eye disease (TED), an autoimmune condition associated with thyroid dysfunction. In this randomized controlled clinical trial, 82 patients were randomly assigned at a 1:1 ratio to receive doxycycline (50 mg) or to undergo no treatment. Various metrics, including margin reflex distance (MRD1 and MRD2), eyelid aperture, levator muscle function, lagophthalmos, proptosis, ocular motility, diplopia, and Graves’ ophthalmopathy-specific quality-of-life (GO-QOL) scale scoring were assessed. Exclusion criteria were uncontrolled systemic diseases, tetracycline allergies, pregnancy, lactation, or age below 18. The mean age was 51.6 years (SD), 87.8% of participants were female, and all were Caucasians. By week 12, the doxycycline group exhibited a significant improvement rate based on MRD2 (from 4 to 15 participants with physiological findings), clinical activity score (from 7 to 35 participants with non-active disease), and GO-QOL (from 51.22% to 70.73% of participants with a good life quality). Doxycycline showcased anti-inflammatory and immunomodulatory effects in treating TED, suggesting its potential efficacy for TED and other orbit inflammatory conditions. However, these results warrant further validation through future research involving extended follow-up periods and larger cohorts.

1 January 2024 in Case Reports in Oncology
Verified
Journal Article
Open access
PDF file
OZOgnjen Zrinšćak
Ognjen Zrinšćak
AKArmin Kasumovic
Armin Kasumovic
IKIva Krolo
Iva Krolo
RIRenata Ivekovic
Renata Ivekovic
MRMaja Malenica Ravlić
Maja Malenica Ravlić
ZVZoran Vatavuk
Zoran Vatavuk
Introduction: This study is a case of solitary clear cell renal cell carcinoma (ccRCC) eyelid metastasis in a 66-year-old man as the first sign of a primary tumor. ccRCC usually spreads to the lungs, mediastinum, bones, liver, and brain, while ocular metastases are rare. Case Presentation: Solitary metastasis presented as a solid mass in the central third of the upper eyelid, which has been growing for 3 weeks. Treatment included tumor removal and blepharoplasty. Histopathological examination showed metastasis of clear cell renal carcinoma. A thorough examination revealed a primary tumor on the lower pole of the right kidney. A right nephrectomy was performed, and histopathology showed ccRCC. Postoperative examinations showed no signs of local or systemic disease. Sunitinib malate was administered to the patient. Conclusion: The eyelid metastasis in this case was still solitary and had been discovered before the existence of the primary tumor was known. Ocular metastasis of renal carcinoma is a rare initial manifestation of the disease and therefore requires a multidisciplinary approach in the treatment of these patients.

29 September 2026 in Medicina
Verified
Journal Article
Open access
PDF file
AKArmin Kasumovic
Armin Kasumovic
IKInes Matoc Kasumovic
Ines Matoc Kasumovic
ABAida Kasumovic Becirevic
Aida Kasumovic Becirevic
IMIvan Merdzo
Ivan Merdzo
AJAjla Jahić
Ajla Jahić
SKSanja Sefić Kasumović
Sanja Sefić Kasumović
Background and Objectives: Diabetes mellitus (DM) may induce structural and biochemical changes in the cornea that can potentially affect corneal transparency. This study aimed to compare corneal optical density (COD) between patients with type 2 diabetes mellitus (T2DM) and healthy controls and to evaluate its association with disease duration. Materials and Methods: This observational cross-sectional study included 90 eyes of 90 participants, with only one eye per participant included in the analysis. The study population comprised 45 eyes from patients with T2DM and 45 age- and gender-matched healthy control eyes. The study was conducted at a specialized ophthalmology center between September 2025 and April 2026. All participants underwent a comprehensive ophthalmic examination followed by corneal densitometry and pachymetry assessment using the Pentacam AXL (Oculus Optikgeräte GmbH, Wetzlar, Germany). COD was analyzed across the total, anterior, central, and posterior corneal layers within the 0–2 mm, 2–6 mm, and 6–10 mm annular zones. COD values and central corneal thickness (CCT) were compared between groups, and correlations between disease duration and COD parameters were evaluated. Results: No statistically significant differences in COD were observed between patients with T2DM and healthy controls across any of the analyzed corneal layers or annular zones (all p > 0.05). CCT also did not differ significantly between groups (p = 0.817). No significant correlations were identified between disease duration and COD parameters (all p > 0.05). Conclusions: In this age- and gender-matched cohort, patients with T2DM did not demonstrate statistically significant differences in corneal densitometry or CCT compared with healthy controls. Disease duration was not significantly associated with COD, suggesting that other factors, including long-term glycaemic control and disease severity, may contribute to diabetes-related corneal alterations.

7 October 2026 in Medicina
Verified
Journal Article
Open access
PDF file
ABAida Kasumovic Becirevic
Aida Kasumovic Becirevic
AKArmin Kasumovic
Armin Kasumovic
IKInes Matoc Kasumovic
Ines Matoc Kasumovic
IMIvan Merdzo
Ivan Merdzo
AKAna Kovač
Ana Kovač
SKSanja Sefić Kasumović
Sanja Sefić Kasumović
Background and Objectives: Diabetes mellitus (DM) is associated with structural and biochemical changes in the cornea that may influence its biomechanical behavior. This study aimed to compare corneal biomechanical properties between healthy individuals and patients with type 2 DM. Materials and Methods: This observational cross-sectional study was conducted at a specialized ophthalmology center from September 2025 to April 2026 and included 115 eyes, which were divided into two groups: 60 healthy control eyes and 55 eyes of patients with DM type 2 (DM2 group). All subjects underwent a complete ophthalmological examination and corneal biomechanical screening using Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). The study included participants aged 50–70 years, with central corneal thickness from 500 to 600 μm, and normal ocular findings. Exclusion criteria included a history of any previous corneal disease, uveitis, glaucoma, spherical refractive errors exceeding ±3.00 D, cylindrical refractive errors exceeding 3.00 D, prior ocular surgery, contact lens wear and systemic connective tissue diseases. Results: DM2 group was older than the control group (median age 63 years [IQR 57–68] vs. 56 years [IQR 54–59], p < 0.001). In unadjusted comparisons, deformation amplitude at highest concavity (DA HC) was higher in the DM2 group (1.05 [0.98–1.09] vs. 0.98 [0.91–1.06] mm, p = 0.002), as was integrated radius (IR) (8.00 [7.53–8.40] vs. 7.50 [6.60–8.60] mm−1, p = 0.032), whereas radius of curvature at highest concavity (RC HC) (7.41 [6.77–7.86] vs. 7.52 [7.10–8.04] mm, p = 0.038) and stiffness parameter at first applanation (SP-A1) (115.50 [102.18–128.40] vs. 122.50 [107.90–142.90] mmHg/mm, p = 0.023) were lower. After adjustment for age, gender, central corneal thickness and intraocular pressure, only DA HC remained independently associated with DM2 status (β = 0.033 mm, 95% CI 0.007–0.058; p = 0.012). Conclusions: Patients with type 2 DM exhibited a corneal biomechanical profile characterized by greater corneal deformability, reflected by higher DA HC and IR values and lower RC HC and SP-A1 values in unadjusted comparisons. Of these parameters, increased DA HC remained independently associated with DM2 after multivariable adjustment. These findings highlight the complexity of diabetes-related corneal biomechanical alterations and suggest that they may not uniformly manifest as increased corneal stiffness.

19 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
GMGoran Marić
Goran Marić
DMDanny Mammo
Danny Mammo
AVAnte Vukojević
Ante Vukojević
AKArmin Kasumovic
Armin Kasumovic
MGMia Zorić Geber
Mia Zorić Geber
ZVZoran Vatavuk
Zoran Vatavuk
Purpose: The aim of this study is to describe a slit-modified 23-gauge infusion trocar designed to enable early postoperative hypotony-free sclerotomy closure by allowing scleral suturing prior to complete trocar removal, and to report initial clinical outcomes in eyes with proliferative diabetic retinopathy with or without vitreous hemorrhage (PDR + H and PDR). Methods: A standard 23-gauge metallic (titanium) trocar was modified by creating a longitudinal slit that permitted passage of a suture needle while the trocar remained partially engaged within the scleral tunnel. At the end of pars plana vitrectomy, a transscleral suture was placed through the slit with the knot prepared prior to trocar removal, followed by simultaneous trocar extraction and suture tightening. Eighteen consecutive patients undergoing vitrectomy for PDR (fourteen with vitreous hemorrhage [PDR + H]; four without) were included. Intraocular pressure (IOP) was recorded preoperatively, immediately after sclerotomy closure (postoperative baseline), and at 8 and 24 h postoperatively. The study was designed as an exploratory pilot feasibility and safety evaluation of a slit-modified infusion trocar in 23-gauge vitrectomy. The primary outcomes were postoperative IOP stability and wound leakage. Secondary outcomes included early hypotony, postoperative hemorrhage, choroidal effusion, and the need for additional suturing. Results: All procedures were completed without intraoperative complications. The mean IOP was 14.83 ± 2.50 mmHg preoperatively, 13.33 ± 1.53 mmHg immediately after closure, 14.17 ± 3.01 mmHg at 8 h, and 15.17 ± 1.79 mmHg at 24 h. No cases of wound leakage or early postoperative hypotony were observed in either subgroup. One eye exhibited a transient IOP increase at 8 h; no choroidal effusion, postoperative hemorrhage, or need for secondary suturing occurred. Endotamponade consisted of balanced salt solution (BSS) in eight eyes, SF6 in seven eyes, silicone oil in two eyes, and air in one eye. Conclusions: The slit-modified infusion trocar enables secure, hypotony-free closure of the infusion sclerotomy by eliminating the open-wound interval during trocar removal. This simple biomedical device modification provides stable early postoperative IOP across different tamponade agents and appears safe and feasible in high-risk eyes with PDR.

22 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
GMGoran Marić
Goran Marić
DMDanny Mammo
Danny Mammo
AVAnte Vukojević
Ante Vukojević
AKArmin Kasumovic
Armin Kasumovic
MGMia Zorić Geber
Mia Zorić Geber
ZVZoran Vatavuk
Zoran Vatavuk
Purpose: To describe a slit-modified 23-gauge infusion trocar designed to enable early postoperative hypotony-free sclerotomy closure by allowing scleral suturing prior to complete trocar removal, and to report initial clinical outcomes in eyes with proliferative diabetic retinopathy with or without vitreous hemorrhage (PDR+H and PDR). Methods: A standard 23-gauge metallic (titanium) trocar was modified by creating a longitudinal slit that permits passage of a suture needle while the trocar remains partially engaged within the scleral tunnel. At the end of pars plana vitrectomy, a transscleral suture was placed through the slit with the knot prepared prior to trocar removal, followed by simultaneous trocar extraction and suture tightening. Eighteen consecutive patients undergoing vitrectomy for PDR (14 with vitreous hemorrhage [PDR+H], 4 without) were included. Intraocular pressure (IOP) was recorded preoperatively, immediately after sclerotomy closure (postoperative baseline), and at 8 and 24 hours postoperatively. Primary outcomes were postoperative IOP stability and wound leakage. Secondary outcomes included early hypotony, postoperative hemorrhage, choroidal effusion, and the need for additional suturing. Results: All procedures were completed without intraoperative complications. Mean IOP was 14.83 ± 2.50 mmHg preoperatively, 13.33 ± 1.53 mmHg immediately after closure, 14.17 ± 3.01 mmHg at 8 hours, and 15.17 ± 1.79 mmHg at 24 hours. No cases of wound leakage or early postoperative hypotony were observed in either subgroup. One eye exhibited a transient IOP increase at 8 hours; no choroidal effusion, postoperative hemorrhage, or need for secondary suturing occurred. Endotamponade consisted of balanced salt solution (BSS) in 8 eyes, SF6 in 7 eyes, silicone oil in 2 eyes, and air in 1 eye. Conclusions: The slit-modified infusion trocar enables secure, hypotony-free closure of the infusion sclerotomy by eliminating the open-wound interval during trocar removal. This simple biomedical device modification provides stable early postoperative IOP across different tamponade agents and appears safe and feasible in high-risk eyes with PDR.