Noah Silvaggio

Mr. Noah Silvaggio

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
LFLogan Froese
Logan Froese
KSKevin Y Stein
Kevin Y Stein
NVNuray Vakitbilir
Nuray Vakitbilir
AGAlwyn Gomez
Alwyn Gomez
FZFrederick Zeiler
Frederick Zeiler
Continuous metrics of cerebral autoregulation (CA) assessment have been developed using various multimodal cerebral physiological monitoring devices. However, CA regional disparity remains unclear in states of health and disease. Leveraging existing archived data sources, we preliminarily evaluated regional hemispheric disparity in CA using the near infrared spectroscopy (NIRS)-derived cerebral oximetry index (COx/COx-a). Along with bilateral NIRS, regional cerebral oxygen saturation, arterial blood pressure, cerebral perfusion pressure, and bilateral COx/COx-a were derived using three different temporal resolutions—10 s, 1 min, and 5 min—based on non-overlapping mean values. The regional disparity between hemispheres was evaluated based on median and median absolute deviation. Further, patient-level autoregressive integrative moving average models were calculated for each signal stream and used to generate personalized vector autoregressive models. Multi-variate cerebral physiologic relationships between hemispheres were assessed via impulse response functions and Granger causality analyses. Data from 102 healthy control volunteers, 27 spinal surgery patients, and 95 TBI patients (varying in frontal lobe pathology impacting the optode path; 64 without bifrontal lobe pathology, 15 without left frontal lobe pathology, 11 without right frontal lobe pathology, and 5 with bifrontal lobe pathology) were retrospectively analyzed. For subjects with or without cranial pathology, no difference in COx/COx-a was found between hemispheres regardless of the analytic method. In TBI patients without pathology underneath the NIRS sensor, distant parenchymal injury does not seem to have an effect on the CA of uninjured frontal lobes. Further work is required to characterize regional disparities with multi-channel CA measurements in healthy and disease states.

21 June 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
LFLogan Froese
Logan Froese
KSKevin Y Stein
Kevin Y Stein
NVNuray Vakitbilir
Nuray Vakitbilir
RHRakibul Hasan
Rakibul Hasan
FZFrederick Zeiler
Frederick Zeiler
Cerebral near-infrared spectroscopy (NIRS) systems have been demonstrated to continuously measure aspects of oxygen delivery and cerebrovascular reactivity. However, it remains unknown whether the prediction of these cerebral physiologic signals into the future is feasible. Leveraging existing archived data sources, four point and interval-forecasting methods using autoregressive integrative moving average (ARIMA) models were evaluated to assess their ability to predict NIRS cerebral physiologic signals. NIRS-based regional cerebral oxygen saturation (rSO2) and cerebral oximetry index signals were derived in three temporal resolutions (10 s, 1 min, and 5 min). Anchored- and sliding-window forecasting, with varying model memory, using point and interval approaches were used to forecast signals using fitted optimal ARIMA models. The absolute difference in the forecasted and measured data was evaluated with median absolute deviation, along with root mean squared error analysis. Further, Pearson correlation and Bland–Altman statistical analyses were performed. Data from 102 healthy controls, 27 spinal surgery patients, and 101 traumatic brain injury patients were retrospectively analyzed. All ARIMA-based point and interval prediction models demonstrated small residuals, while correlation and agreement varied based on model memory. The ARIMA-based sliding-window approach performed superior to the anchored approach due to data partitioning and model memory. ARIMA-based sliding-window forecasting using point and interval approaches can forecast rSO2 and the cerebral oximetry index with reasonably small residuals across all populations. Correlation and agreement between the predicted versus actual values varies substantially based on data-partitioning methods and model memory. Further work is required to assess the ability to forecast high-frequency NIRS signals using ARIMA and ARIMA-variant models in healthy and cranial trauma populations.

1 December 2024 in Physiological Measurement
Verified
Journal Article
Open access
TBTobias Joshua Gordon Bergmann
Tobias Joshua Gordon Bergmann
NVNuray Vakitbilir
Nuray Vakitbilir
AGAlwyn Gomez
Alwyn Gomez
AIAbrar Islam
Abrar Islam
KSKevin Y Stein
Kevin Y Stein
FZFrederick Zeiler
Frederick Zeiler
Objective. Intracranial pressure measurement (ICP) is an essential component of deriving of multivariate data metrics foundational to improving understanding of high temporal relationships in cerebral physiology. A significant barrier to this work is artifact ridden data. As such, the objective of this review was to examine the existing literature pertinent to ICP artifact management. Methods. A search of five databases (BIOSIS, SCOPUS, EMBASE, PubMed, and Cochrane Library) was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines with the PRISMA Extension for Scoping Review. The search question examined the methods for artifact management for ICP signals measured in human/animals. Results. The search yielded 5875 unique results. There were 19 articles included in this review based on inclusion/exclusion criteria and article references. Each method presented was categorized as: (1) valid ICP pulse detection algorithms and (2) ICP artifact identification and removal methods. Machine learning-based and filter-based methods indicated the best results for artifact management; however, it was not possible to elucidate a single most robust method. Conclusion. There is a significant lack of standardization in the metrics of effectiveness in artifact removal which makes comparison difficult across studies. Differences in artifacts observed on patient neuropathological health and recording methodologies have not been thoroughly examined and introduce additional uncertainty regarding effectiveness. Significance. This work provides critical insights into existing literature pertaining to ICP artifact management as it highlights holes in the literature that need to be adequately addressed in the establishment of robust artifact management methodologies.

3 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
NSNoah Silvaggio
Noah Silvaggio
KSKevin Y Stein
Kevin Y Stein
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
NVNuray Vakitbilir
Nuray Vakitbilir
TBTobias Joshua Gordon Bergmann
Tobias Joshua Gordon Bergmann
FZFrederick Zeiler
Frederick Zeiler
Cerebral blood volume (CBV) is an essential metric that indicates and evaluates various healthy and pathologic conditions. Most methods of CBV measurement are cumbersome and have a poor temporal resolution. Recently, it has been proposed that signals and derived metrics from cerebral near-infrared spectroscopy (NIRS), a non-invasive sensor, can be used to estimate CBV. However, this association remains vastly unexplored. As such, this scoping review aimed to examine the literature on the relationship between cerebral NIRS signals and CBV. A search of six databases was conducted conforming to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to assess the following search question: What are the associations between various NIRS cerebral signals and CBV? The database search yielded 3350 unique results. Seven of these articles were included in this review based on the inclusion and exclusion criteria. An additional study was identified and included while examining the articles’ reference sections. Overall, the literature for this systematic scoping review shows extreme variation in the association between cerebral NIRS signals and CBV, with few sources objectively documenting a true statistical association between the two. This review highlights the current critical knowledge gap and emphasizes the need for further research in the area.

20 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AIAbrar Islam
Abrar Islam
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
KSKevin Y Stein
Kevin Y Stein
NVNuray Vakitbilir
Nuray Vakitbilir
AGAlwyn Gomez
Alwyn Gomez
FZFrederick Zeiler
Frederick Zeiler
Goal: Current methodologies for assessing cerebral compliance using pressure sensor technologies are prone to errors and issues with inter- and intra-observer consistency. RAP, a metric for measuring intracranial compensatory reserve (and therefore compliance), holds promise. It is derived using the moving correlation between intracranial pressure (ICP) and the pulse amplitude of ICP (AMP). RAP remains largely unexplored in cases of moderate to severe acute traumatic neural injury (also known as traumatic brain injury (TBI)). The goal of this work is to explore the general description of (a) RAP signal patterns and behaviors derived from ICP pressure transducers, (b) temporal statistical relationships, and (c) the characterization of the artifact profile. Methods: Different summary and statistical measurements were used to describe RAP’s pattern and behaviors, along with performing sub-group analyses. The autoregressive integrated moving average (ARIMA) model was employed to outline the time-series structure of RAP across different temporal resolutions using the autoregressive (p-order) and moving average orders (q-order). After leveraging the time-series structure of RAP, similar methods were applied to ICP and AMP for comparison with RAP. Finally, key features were identified to distinguish artifacts in RAP. This might involve leveraging ICP/AMP signals and statistical structures. Results: The mean and time spent within the RAP threshold ranges ([0.4, 1], (0, 0.4), and [−1, 0]) indicate that RAP exhibited high positive values, suggesting an impaired compensatory reserve in TBI patients. The median optimal ARIMA model for each resolution and each signal was determined. Autocorrelative function (ACF) and partial ACF (PACF) plots of residuals verified the adequacy of these median optimal ARIMA models. The median of residuals indicates that ARIMA performed better with the higher-resolution data. To identify artifacts, (a) ICP q-order, AMP p-order, and RAP p-order and q-order, (b) residuals of ICP, AMP, and RAP, and (c) cross-correlation between residuals of RAP and AMP proved to be useful at the minute-by-minute resolution, whereas, for the 10-min-by-10-min data resolution, only the q-order of the optimal ARIMA model of ICP and AMP served as a distinguishing factor. Conclusions: RAP signals derived from ICP pressure sensor technology displayed reproducible behaviors across this population of TBI patients. ARIMA modeling at the higher resolution provided comparatively strong accuracy, and key features were identified leveraging these models that could identify RAP artifacts. Further research is needed to enhance artifact management and broaden applicability across varied datasets.

7 April 2026 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
KSKevin Y Stein
Kevin Y Stein
LFLogan Froese
Logan Froese
ASAmanjyot Singh Sainbhi
Amanjyot Singh Sainbhi
NVNuray Vakitbilir
Nuray Vakitbilir
TBTobias Joshua Gordon Bergmann
Tobias Joshua Gordon Bergmann
FZFrederick Zeiler
Frederick Zeiler
Individualized intracranial pressure (iICP) thresholds, defined as the function intersectionality between intracranial pressure (ICP) and cerebrovascular r