Carlo Poselle Bonaventura

Mr. Carlo Poselle Bonaventura

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TGTeresa Gerace
Teresa Gerace
Sebastiano CandamanoSebastiano Candamano
Sebastiano Candamano
SBSimone Bartucci
Simone Bartucci
CBCarlo Poselle Bonaventura
Carlo Poselle Bonaventura
Alfonso PolicicchioAlfonso Policicchio
Alfonso Policicchio
DPDaniela Pacilè
Daniela Pacilè
Cement composites containing different carbon nanomaterials, namely graphene technical grade, graphene super grade, and graphene oxide, up to 1.0% by weight of cement, were prepared. Ultrasonic, chemical, and thermochemical treatments were applied to improve the stability of the dispersions containing the graphene-based nanomaterials. Their exfoliation was analyzed using Raman spectroscopy, and the stability of the dispersions was quantitatively investigated by means of the static multiple light scattering (SMLS) technique. The sonication process enhanced the intensity of the 2D band of graphene technical grade, suggesting a partial degree of exfoliation, while the hydrothermal treatment with sodium cholate significantly promoted the stability of its dispersion. The effect of the addition of selected graphene-based nanomaterials in mortars was evaluated in terms of fresh state properties, mechanical strength, capillary water absorption, and pore size distribution. Workability decreased with the increase in the amount of carbon nanomaterials. Field emission scanning electron microscopy (FESEM) was also employed to characterize the microstructure of pristine graphene-based nanomaterials and their inclusion within the cement matrix. Our results suggest that mechanical properties are only moderately affected by the inclusion of all additives, whereas the introduction of graphene significantly influences the coefficient of capillary water absorption. Specifically, a reduction of about 20% in the capillary water absorption coefficient was observed at the concentration of 1.0 wt% of graphene technical grade, which is ascribed to a refinement of the porosity.

23 September 2026 in Polymers
Verified
Journal Article
Open access
PDF file
LMLuigi Madeo
Luigi Madeo
CBCarlo Poselle Bonaventura
Carlo Poselle Bonaventura
PCPaola Caputo
Paola Caputo
Anastasia MacarioAnastasia Macario
Anastasia Macario
Sebastiano CandamanoSebastiano Candamano
Sebastiano Candamano
De Luca PierantonioDe Luca Pierantonio
De Luca Pierantonio
This study presents the development of sustainable and multifunctional geopolymer composites produced from recycled volcanic ash collected from Mount Etna (Italy), used as an aluminosilicate precursor for the fabrication of environmentally friendly materials. Geopolymerization was activated using a 6 M sodium hydroxide (NaOH) solution. The geopolymer matrix was optimized by investigating three liquid-to-solid (L/S) ratios (0.2, 0.3, and 0.4) in order to identify the most suitable formulation in terms of microstructure and porosity. SEM, EDS, BET, particle size distribution (PSD), and X-ray diffraction (XRD) analyses identified an L/S ratio of 0.3 as the optimal formulation. Based on this optimized matrix, graphene nanoparticles were incorporated at concentrations of 0.1, 0.2, and 0.5 wt.% to evaluate their influence on the microstructural, thermal, mechanical, and durability-related properties of the composites. The resulting materials were characterized by SEM, EDS, XRD, differential scanning calorimetry (DSC), mechanical testing, and water absorption measurements. Finally, hybrid prototypes consisting of geopolymer bars coated with a transparent epoxy resin containing photoluminescent powder were fabricated. Their photoluminescent performance was qualitatively evaluated following direct solar irradiation by monitoring the persistence of light emission over time. The results demonstrate the feasibility of integrating a geopolymer matrix derived from volcanic waste, graphene nanoparticles, and a photoluminescent coating into a single sustainable and multifunctional material. Although this work represents a preliminary proof-of-concept study, it provides a promising foundation for the development of smart geopolymer-based materials for applications in civil infrastructure, passive safety systems, and guidance devices operating under low-light conditions.

11 September 2026 in C
Verified
Journal Article
Open access
PDF file
LMLuigi Madeo
Luigi Madeo
CBCarlo Poselle Bonaventura
Carlo Poselle Bonaventura
PFPietro Figliuzzi
Pietro Figliuzzi
CSCarlo Siciliano
Carlo Siciliano
Anastasia MacarioAnastasia Macario
Anastasia Macario
De Luca PierantonioDe Luca Pierantonio
De Luca Pierantonio
Cigarette smoke is a significant source of indoor air pollution, containing particulate matter and numerous volatile and semi-volatile organic compounds. This study evaluates the adsorption performance of two commercial activated carbons, Nuchar SA 1500 (SA) and Filtercarbon PHA (PHA), correlating their pore structure with their ability to retain cigarette smoke contaminants. A two-stage laboratory filtration system was developed to analyze the non-retained fraction using a downstream cellulose filter, employed as an indirect indicator of adsorption efficiency. BET/NLDFT, SEM/EDS, and thermogravimetric analyses show that Nuchar SA 1500, characterized by a more developed micro-mesoporous network, retains a larger fraction of particulate matter and condensable compounds compared with Filtercarbon PHA. Based on preliminary investigations, which revealed a markedly higher adsorption behavior for Nuchar SA 1500, the analytical focus was directed toward this material; consequently, GC–MS analysis was performed only on Nuchar SA 1500, excluding Filtercarbon PHA.

1 May 2026 in Green Carbon
Verified
Journal Article
Open access
DCDaniela Cozza
Daniela Cozza
CBCarlo Poselle Bonaventura
Carlo Poselle Bonaventura
OLOreste De Luca
Oreste De Luca
GFGiorgia Ferrarelli
Giorgia Ferrarelli
GCGiuseppe Conte
Giuseppe Conte
MMMassimo Migliori
Massimo Migliori

17 September 2026 in Materials Research Express
Verified
Journal Article
Open access
TGTeresa Gerace
Teresa Gerace
DPDaniela Pacilè
Daniela Pacilè
SCSebastiano Candamano
Sebastiano Candamano
Alfonso PolicicchioAlfonso Policicchio
Alfonso Policicchio
CBCarlo Poselle Bonaventura
Carlo Poselle Bonaventura
Sandro DonatoSandro Donato
Sandro Donato
The presence of an internal pore structure is an intrinsic characteristic of all cementitious compounds, with pore sizes spanning from angstroms to millimetres. Investigating porosity is crucial to understand and predict the mechanical and transport behaviour of cement-based materials; however, no single experimental technique is capable of capturing the full range of pore sizes, making a multi-scale approach necessary. In this study, three types of cement mortar are examined: a control mortar with no additives (C), and two graphene-doped mortars containing 1 wt% of graphene technical grade (1TG) and 1 wt% of graphene oxide (1GO), respectively. Consistency, flexural and compressive strength, and capillary water absorption (CWA), previously reported, are correlated with the pore structure, characterized by nitrogen physisorption ( N 2 ), mercury intrusion porosimetry (MIP), and x-ray microcomputed tomography ( μ -CT). Despite a considerable reduction in consistency, the doped mortars, 1TG and 1GO, do not show appreciable variations in compressive strength compared to mortar C, while they show a reduction in CWA of the 22% and 15% respectively. Morphological analysis was conducted on data collected by μ -CT: mortar C shows a significant contribution of low-sphericity pores associated with microcracks, 1GO is dominated by highly spherical pores consistent with entrapped air voids, and 1TG presents a broader distribution of sphericity. Overall, analysing and merging the pore size distribution data obtained from N 2 , MIP and μ -CT, allowed us to cover a range of pore size from 2 nm to 10 mm and correlate the macroscopic behaviour to the internal pore structure of cement mortars.