Sandro Donato

Dr. Sandro Donato

Physics, University of Calabria, Rende, Italy
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2011 in Nonlinear Processes in Geophysics
Verified
Journal Article
Open access
PDF file
SSSergio Servidio
Sergio Servidio
PDP. Dmitruk
P. Dmitruk
AGA. Greco
A. Greco
MWMinping Wan
Minping Wan
Sandro DonatoSandro Donato
Sandro Donato
WMW. H. Matthaeus
W. H. Matthaeus
In this work, recent advances on the study of reconnection in turbulence are reviewed. Using direct numerical simulations of decaying incompressible two-dimensional magnetohydrodynamics (MHD), it was found that in fully developed turbulence complex processes of reconnection locally occur (Servidio et al., 2009, 2010a). In this complex scenario, reconnection is spontaneous but locally driven by the fields, with the boundary conditions provided by the turbulence. Matching classical turbulence analysis with a generalized Sweet-Parker theory, the statistical features of these multiple-reconnection events have been identified. A discussion on the accuracy of our algorithms is provided, highlighting the necessity of adequate spatial resolution. Applications to the study of solar wind discontinuities are reviewed, comparing simulations to spacecraft observations. New results are shown, studying the time evolution of these local reconnection events. A preliminary study on the comparison between MHD and Hall MHD is reported. Our new approach to the study of reconnection as an element of turbulence has broad applications to space plasmas, shedding a new light on the study of magnetic reconnection in nature.

14 June 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
RLRenata Longo
Renata Longo
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
UBUbaldo Bottigli
Ubaldo Bottigli
LBLUCA BROMBAL
LUCA BROMBAL
GTGiuliana Tromba
Giuliana Tromba

1 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
DDDiego Dreossi
Diego Dreossi
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
RLRenata Longo
Renata Longo
X-ray phase imaging has the potential to dramatically improve soft tissue contrast sensitivity, which is a crucial requirement in many diagnostic applications such as breast imaging. In this context, a program devoted to perform in vivo phase-contrast synchrotron radiation breast computed tomography is ongoing at the Elettra facility (Trieste, Italy). The used phase-contrast technique is the propagation-based configuration, which requires a spatially coherent source and a sufficient object-to-detector distance. In this work the effect of this distance on image quality is quantitatively investigated scanning a large breast surgical specimen at three object-to-detector distances (1.6, 3, 9 m) and comparing the images both before and after applying the phase-retrieval procedure. The sample is imaged at 30 keV with a pixel pitch CdTe single-photon-counting detector, positioned at a fixed distance of 31.6 m from the source. The detector fluence is kept constant for all acquisitions. The study shows that, at the largest distance, a 20-fold SNR increase can be obtained by applying the phase-retrieval procedure. Moreover, it is shown that, for phase-retrieved images, changing the object-to-detector distance does not affect spatial resolution while boosting SNR (four-fold increase going from the shortest to the largest distance). The experimental results are supported by a theoretical model proposed by other authors, whose salient results are presented in this paper.

1 September 2012 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
Sandro DonatoSandro Donato
Sandro Donato
SSSergio Servidio
Sergio Servidio
PDP. Dmitruk
P. Dmitruk
Vincenzo CarboneVincenzo Carbone
Vincenzo Carbone
MSM. A. Shay
M. A. Shay
WMW. H. Matthaeus
W. H. Matthaeus
The statistical study of magnetic reconnection events in two-dimensional turbulence has been performed by comparing numerical simulations of magnetohydrodynamics (MHD) and Hall magnetohydrodynamics (HMHD). The analysis reveals that the Hall term plays an important role in turbulence, in which magnetic islands simultaneously reconnect in a complex way. In particular, an increase of the Hall parameter, the ratio of ion skin depth to system size, broadens the distribution of reconnection rates relative to the MHD case. Moreover, in HMHD the local geometry of the reconnection region changes, manifesting bifurcated current sheets and quadrupolar magnetic field structures in analogy to laminar studies, leading locally to faster reconnection processes in this case of reconnection embedded in turbulence. This study supports the idea that the global rate of energy dissipation is controlled by the large scale turbulence, but suggests that the distribution of the reconnection rates within the turbulent system is sensitive to the microphysics at the reconnection sites.

28 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
FAFulvia Arfelli
Fulvia Arfelli
PDPasquale Delogu
Pasquale Delogu
Sandro DonatoSandro Donato
Sandro Donato
GMGiovanni Mettivier
Giovanni Mettivier
CFChristian Fedon
Christian Fedon
In this study we compared the image quality of a synchrotron radiation (SR) breast computed tomography (BCT) system with a clinical BCT in terms of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), noise power spectrum (NPS), spatial resolution and detail visibility. A breast phantom consisting of several slabs of breast-adipose equivalent material with different embedded targets (i.e., masses, fibers and calcifications) was used. Phantom images were acquired using a dedicated BCT system installed at the Radboud University Medical Center (Nijmegen, The Netherlands) and the SR BCT system at the SYRMEP beamline of Elettra SR facility (Trieste, Italy) based on a photon-counting detector. Images with the SR setup were acquired mimicking the clinical BCT conditions (i.e., energy of 30 keV and radiation dose of 6.5 mGy). Images were reconstructed with an isotropic cubic voxel of 273 µm for the clinical BCT, while for the SR setup two phase-retrieval (PhR) kernels (referred to as “smooth” and “sharp”) were alternatively applied to each projection before tomographic reconstruction, with voxel size of 57 × 57 × 50 µm3. The CNR for the clinical BCT system can be up to 2-times higher than SR system, while the SNR can be 3-times lower than SR system, when the smooth PhR is used. The peak frequency of the NPS for the SR BCT is 2 to 4-times higher (0.9 mm−1 and 1.4 mm−1 with smooth and sharp PhR, respectively) than the clinical BCT (0.4 mm−1). The spatial resolution (MTF10%) was estimated to be 1.3 lp/mm for the clinical BCT, and 5.0 lp/mm and 6.7 lp/mm for the SR BCT with the smooth and sharp PhR, respectively. The smallest fiber visible in the SR BCT has a diameter of 0.15 mm, while for the clinical BCT is 0.41 mm. Calcification clusters with diameter of 0.13 mm are visible in the SR BCT, while the smallest diameter for the clinical BCT is 0.29 mm. As expected, the image quality of the SR BCT outperforms the clinical BCT system, providing images with higher spatial resolution and SNR, and with finer granularity. Nevertheless, this study assesses the image quality gap quantitatively, giving indications on the benefits associated with SR BCT and providing a benchmarking basis for its clinical implementation. In addition, SR-based studies can provide a gold-standard in terms of achievable image quality, constituting an upper-limit to the potential clinical development of a given technique.

1 June 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
Francesco BrunFrancesco Brun
Francesco Brun
PDPasquale Delogu
Pasquale Delogu
VFViviana Fanti
Viviana Fanti
BGBruno Golosio
Bruno Golosio