Yingjie Zhang

Mr. Yingjie Zhang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2025 in Machines
Verified
Journal Article
Open access
PDF file
JLJianwei Li
Jianwei Li
PYPanpan Yang
Panpan Yang
XHXuemei Huang
Xuemei Huang
YZYingjie Zhang
Yingjie Zhang
JWJinghua Wang
Jinghua Wang
Wind turbine blades are prone to icing in cold environments, which leads to decreased aerodynamic performance, increased power loss, and even endangers the safe and stable operation of wind turbines. Electric heating anti-deicing method is the most effective solution because of its flexible control, rapid response, and high deicing efficiency. However, in the process of blade high-speed rotation, the complex flow field effect significantly affects the blade heat transfer performance, which leads to the problems of high energy consumption, low heat utilization, and uneven heating of traditional electric heating anti-icing/deicing methods, limiting their application effect in complex working conditions. Based on the physical mechanism and heat exchange characteristics of electric heating deicing of wind turbine blades, a coupled flow–heat transfer numerical model suitable for complex flow field conditions was constructed in this study, aiming to realize the dynamic simulation of the global temperature field and the phase transition process of ice sheets under different heating modes. Furthermore, the deicing efficiency characteristics of continuous heating and cyclic heating modes were compared and analyzed. The blade tip section of a Sinoma87.5 was taken as the experimental object, and the deicing experiment of blade by electric heating was carried out under artificial ice-covering laboratory conditions. The simulation and experimental results show that the deicing process by electric heating can be divided into three typical stages: initial temperature rise, stagnation, and rapid temperature rise. Under the influence of incoming flow conditions, the temperature rise of the front stagnation point region lags behind that of the windward side, and the steady-state peak temperature is lower. Compared with the cyclic heating mode, the continuous heating mode can enter and cross the stagnation period more quickly. The peak steady-state temperature of the continuous heating mode is 24.2 °C, and the deviation from the simulation result is only 2.8 °C, which is within the acceptable error range, effectively verifying the reliability of the numerical calculation model established.

26 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
YZYingjie Zhang
Yingjie Zhang
ZQZhiwen Qin
Zhiwen Qin
YZYuhuan Zhang
Yuhuan Zhang
JLJialin Li
Jialin Li
LZLeian Zhang
Leian Zhang
PYPanpan Yang
Panpan Yang
Significant vibrations of the traction wire rope can impact the efficiency and accuracy of static testing in wind turbine blade assessments. This study focuses on the vibration characteristics of the wire rope under static loading conditions. A simulation model for single-point static tests of wind turbine blades was developed using Adams software and validated through wire rope tension and longitudinal acceleration measurements during static tests on a full-scale 71.5-m blade. The validated model was used to analyze the effects of wire rope span and pulley position on vibration amplitude and tension in single-point loading scenarios. The results show that increasing the wire rope span and the distance between the pulley and blade fixture significantly amplifies vibration. Adjusting the span of the wire rope and the pulley position causes the primary vibration frequency to approach the natural frequency, leading to a substantial increase in vibration near the resonance frequency. To avoid resonance and reduce vibration, it is recommended to use two misaligned ground tracks, ensuring the wire rope span does not exceed 30 m and the distance between the pulley and blade fixture does not exceed 7 m. Specific resonance combinations of wire rope span and pulley position should be avoided to improve the precision and reliability of the testing system.