Nuno Miguel dos Santos Pinto da Silva

Dr. Nuno Miguel dos Santos Pinto da Silva

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Raul MoraisRaul Morais
Raul Morais
NSNuno Miguel dos Santos Pinto da Silva
Nuno Miguel dos Santos Pinto da Silva
PSPaulo M. Santos
Paulo M. Santos
CFClara M. Frias
Clara M. Frias
JFJorge Ferreira
Jorge Ferreira
Manuel José Cabral dos Santos ReisManuel José Cabral dos Santos Reis
Manuel José Cabral dos Santos Reis

30 June 2021 in Agriculture
Verified
Journal Article
Open access
PDF file
Raul MoraisRaul Morais
Raul Morais
JMJorge Mendes
Jorge Mendes
RSRenato Silva
Renato Silva
NSNuno Miguel dos Santos Pinto da Silva
Nuno Miguel dos Santos Pinto da Silva
JSJoaquim J. Sousa
Joaquim J. Sousa
Emanuel PeresEmanuel Peres
Emanuel Peres
Spatial and temporal variability characterization in Precision Agriculture (PA) practices is often accomplished by proximity data gathering devices, which acquire data from a wide variety of sensors installed within the vicinity of crops. Proximity data acquisition usually depends on a hardware solution to which some sensors can be coupled, managed by a software that may (or may not) store, process and send acquired data to a back-end using some communication protocol. The sheer number of both proprietary and open hardware solutions, together with the diversity and characteristics of available sensors, is enough to deem the task of designing a data acquisition device complex. Factoring in the harsh operational context, the multiple DIY solutions presented by an active online community, available in-field power approaches and the different communication protocols, each proximity monitoring solution can be regarded as singular. Data acquisition devices should be increasingly flexible, not only by supporting a large number of heterogeneous sensors, but also by being able to resort to different communication protocols, depending on both the operational and functional contexts in which they are deployed. Furthermore, these small and unattended devices need to be sufficiently robust and cost-effective to allow greater in-field measurement granularity 365 days/year. This paper presents a low-cost, flexible and robust data acquisition device that can be deployed in different operational contexts, as it also supports three different communication technologies: IEEE 802.15.4/ZigBee, LoRa/LoRaWAN and GRPS. Software and hardware features, suitable for using heat pulse methods to measure sap flow, leaf wetness sensors and others are embedded. Its power consumption is of only 83 μA during sleep mode and the cost of the basic unit was kept below the EUR 100 limit. In-field continuous evaluation over the past three years prove that the proposed solution—SPWAS’21—is not only reliable but also represents a robust and low-cost data acquisition device capable of gathering different parameters of interest in PA practices.

1 October 2013 in Journal of Biomechanics
Verified
Journal Article
Closed access
Marco P. Soares dos SantosMarco P. Soares dos Santos
Marco P. Soares dos Santos
JFJorge Ferreira
Jorge Ferreira
António Manuel de Amaral RamosAntónio Manuel de Amaral Ramos
António Manuel de Amaral Ramos
JSJosé A.O. Simões
José A.O. Simões
Raul MoraisRaul Morais
Raul Morais
TOT. Oliveira
T. Oliveira

1 November 2013 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
NSNuno Miguel dos Santos Pinto da Silva
Nuno Miguel dos Santos Pinto da Silva
PSPaulo M. Santos
Paulo M. Santos
JFJorge Ferreira
Jorge Ferreira
Marco P. Soares dos SantosMarco P. Soares dos Santos
Marco P. Soares dos Santos
António Manuel de Amaral RamosAntónio Manuel de Amaral Ramos
António Manuel de Amaral Ramos
Raul MoraisRaul Morais
Raul Morais

1 January 2010 in Procedia Engineering
Verified
Journal Article
Open access
Raul MoraisRaul Morais
Raul Morais
NSNuno Miguel dos Santos Pinto da Silva
Nuno Miguel dos Santos Pinto da Silva
PSP. Santos
P. Santos
CFC. Frias
C. Frias
JFJorge Ferreira
Jorge Ferreira
Manuel José Cabral dos Santos ReisManuel José Cabral dos Santos Reis
Manuel José Cabral dos Santos Reis
This paper describes an improved micro-power electric generator where energy harvested from human movements is used as an everlasting mechanical energy source to suffice smart hip implant electronics power needs. Its architecture is designed so that the mechanical energy promotes the movement of a combination of magnets and a spring embedded inside a Teflon tube, used to reduce friction. The changing magnetic field induces current in two coils so that the output of the generator is the sum of their signals. The end result is like a double generator in one casing. Produced electrical energy is stored in an energy reservoir handed over to a power management module. Experimental results shows that energy harvested from human walking can be used as an effective power source for hip prosthesis implants.

25 July 2014 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
Marco P. Soares dos SantosMarco P. Soares dos Santos
Marco P. Soares dos Santos
JFJorge Ferreira
Jorge Ferreira
António Manuel de Amaral RamosAntónio Manuel de Amaral Ramos
António Manuel de Amaral Ramos
JSJosé Ao Simões
José Ao Simões
Raul MoraisRaul Morais
Raul Morais
TOTatiana Oliveira
Tatiana Oliveira
This paper reviews instrumented hip joint replacements, instrumented femoral replacements and instrumented femoral fracture stabilizers. Examination of the evolution of such implants was carried ou...