Antonio Madaffari

Dr. Antonio Madaffari


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
TKThomas Kueffer
Thomas Kueffer
HTHildegard Tanner
Hildegard Tanner
AMAntonio Madaffari
Antonio Madaffari
JSJens Seiler
Jens Seiler
AHAndreas Haeberlin
Andreas Haeberlin
LRLaurent Roten
Laurent Roten
Aims: The left atrial posterior wall is a potential ablation target in patients with recurrent atrial fibrillation despite durable pulmonary vein isolation or in patients with roof-dependent atrial tachycardia (AT). Pulsed-field ablation (PFA) offers efficient and safe posterior wall ablation (PWA), but available data are scarce. Methods and results: Consecutive patients undergoing PWA using PFA were included. Posterior wall ablation was performed using a pentaspline PFA catheter and verified by 3D-electroanatomical mapping. Follow-up was performed using 7-day Holter ECGs 3, 6, and 12 months after ablation. Recurrence of any atrial arrhythmia lasting more than 30 s was defined as failure. Lesion durability was assessed during redo procedures. Posterior wall ablation was performed in 215 patients (70% males, median age 70 [IQR 61–75] years, 67% redo procedures) and was successful in all patients (100%) by applying a median of 36 (IQR 32–44) PFA lesions. Severe adverse events were cardiac tamponade and vascular access complication in one patient each (0.9%). Median follow-up was 7.3 (IQR 5.0–11.8) months. One-year arrhythmia-free outcome in Kaplan–Meier analysis was 53%. A redo procedure was performed in 26 patients (12%) after a median of 6.9 (IQR 2.4–11) months and showed durable PWA in 22 patients (85%) with only minor lesion regression. Among four patients with posterior wall reconnection, three (75%) presented with roof-dependent AT. Conclusion: Posterior wall ablation with this pentaspline PFA catheter can be safely and efficiently performed with a high durability observed during redo procedures. The added value of durable PWA for the treatment of atrial fibrillation remains to be evaluated.

1 October 2022 in Radiology
Verified
Journal Article
Closed access
AHAdrian Thomas Huber
Adrian Thomas Huber
SFSeverin Fankhauser
Severin Fankhauser
LCLaurève Chollet
Laurève Chollet
SWSeverin Wittmer
Severin Wittmer
ALAnna Lam
Anna Lam
TRTobias Reichlin
Tobias Reichlin
Left atrial enhancing epicardial adipose tissue at preprocedural cardiac CT allowed for the identification of patients who were at high risk for atrial fibrillation recurrence after atrial fibrilla... Background The association of epicardial adipose tissue (EAT) and its metabolic activity with atrial fibrillation (AF) is an area of active investigation. Left atrial (LA) enhancing EAT (e-EAT) at ...

7 June 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
AHAndreas Haeberlin
Andreas Haeberlin
JBJoanna Bartkowiak
Joanna Bartkowiak
NBNicolas Brugger
Nicolas Brugger
HTHildegard Tanner
Hildegard Tanner
EWElaine Wan
Elaine Wan
TRTobias Reichlin
Tobias Reichlin
Introduction: Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation.Methods: Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre‐ and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random‐effects meta‐analysis.Results: We included 69 patients (median age 78 years [interquartile range (IQR) 72–84 years], 26% women). Follow‐up duration between baseline and follow‐up TTE was 11.4 months (IQR 3.5–20.1 months). At follow‐up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow‐up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta‐analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97–1.53, p = .11).Conclusion: To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.

14 June 2022 in EP Europace
Verified
Journal Article
Open access
TKThomas Kueffer
Thomas Kueffer
SBSamuel Baldinger
Samuel Baldinger
HSHelge Servatius
Helge Servatius
AMAntonio Madaffari
Antonio Madaffari
JSJens Seiler
Jens Seiler
TRTobias Reichlin
Tobias Reichlin
Aims: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI. Methods and results: Patients undergoing first PVI using PFA with the standard ablation protocol (eight applications per PV) were studied. Entrance and exit block (10 V/2 ms) were assessed using the PFA catheter. Subsequently, a high-density 3D electroanatomical bipolar voltage map (3D-EAM) was constructed using a standard pentaspline 3D-mapping catheter. Additional PFA applications were delivered only after confirmation of residual PV connection by 3D-EAM. In 56 patients, 213 PVs were targeted for ablation. Acute PVI was achieved in 100% of PVs: in 199/213 (93%) PVs with the standard ablation protocol alone and in the remaining 14 PVs after additional PFA applications. The accuracy of PV assessment with the PFA catheter after the standard ablation protocol was 91% (194/213 veins). In 5/213 (2.3%) PVs, the PFA catheter incorrectly indicated PV-isolation. In 14/213 (6.6%), the PFA catheter incorrectly indicated residual PV-conduction due to high-output pace-capture. Lowering the output to 5 V/1 ms reduced this observation to 0.9% (2/213) and increased the overall accuracy to 97% (206/213). Conclusion: A novel multipolar PFA catheter allows reliable endpoint assessment for PVI. Due to its design, far-field sensing and high-output pace-capture can occur. Lowering the pacing output increases the accuracy from 91 to 97%.

30 March 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
LCLaurève Chollet
Laurève Chollet
SISalik Ur Rehman Iqbal
Salik Ur Rehman Iqbal
SWSeverin Wittmer
Severin Wittmer
GTGregor Thalmann
Gregor Thalmann
AMAntonio Madaffari
Antonio Madaffari
TRTobias Reichlin
Tobias Reichlin
Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.

21 June 2022 in EP Europace
Verified
Journal Article
Closed access
PDF file
SKSven Knecht
Sven Knecht
CSChristian Sticherling
Christian Sticherling
LRLaurent Roten
Laurent Roten
PBPatrick Badertscher
Patrick Badertscher
PKPhilipp Krisai
Philipp Krisai
MKMichael Kühne
Michael Kühne
The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.