Xiangjing Su

Dr. Xiangjing Su


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
XSXiangjing Su
Xiangjing Su
JLJining Liu
Jining Liu
STShuxin Tian
Shuxin Tian
PLPing Ling
Ping Ling
YFYang Fu
Yang Fu
CSChao SiMa
Chao SiMa
The growing penetrations of rooftop photovoltaics (PVs) into low-voltage (LV) distribution networks are challenging voltage regulation. Developing an effective volt-var (VV) control has been the focus of many researchers with various approaches proposed so far. However, assuming a single voltage level and balanced network model, widely adopted in existing literatures, tends to cause inaccurate and even infeasible control solutions. Besides, existing distribution VV control studies are usually based on the day-ahead predictions of PV generations and loads, introducing inevitable and non-negligible errors. To address the challenges above, this paper proposes a VV co-optimization across unbalanced medium-voltage (MV) and LV networks, by traditional and emerging techniques, to ensure the network operation with the required power quality. Specifically, the operation of MV delta-connected switched capacitors and LV distributed PV inverters is coordinated, under a three-stage strategy that suits integrated and unbalanced radial distribution networks. The proposal aims to simultaneously improve voltage magnitude and balance profiles while reducing network power loss, at the least controlling cost. To effectively solve the proposed VV optimization problem, a joint solver of the modified particle swarm optimization and the improved direct load flow is employed. Finally, the proposal is evaluated by simulations on real Australian distribution networks over 24 h.

20 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
ZZZehua Zhao
Zehua Zhao
Jiajia YangJiajia Yang
Jiajia Yang
XSXiangjing Su
Xiangjing Su
YDYang Du
Yang Du
MJMohan Jacob
Mohan Jacob
The increasingly frequent and severe natural disasters have posed significant challenges to the resilience of power systems worldwide, creating an urgent need to investigate the security issues associated with these extreme events and to develop effective risk mitigation strategies. Meanwhile, as one of the leading topics in current research, artificial intelligence (AI) has demonstrated outstanding performance across various domains, such as AI-driven smart grids and smart cities. In particular, its efficiency in processing big data and solving complex computational problems has made AI a powerful tool for supporting decision-making in complex scenarios. This article presents a focused overview of power system resilience against natural disasters, highlighting recent advancements in AI-based approaches aimed at enhancing system security and response capabilities. It begins by introducing various types of natural disasters and their corresponding impacts on power systems. Then, a systematic overview of AI applications in power systems under disaster scenarios is provided, with a classification based on the task categories, i.e., predictive, descriptive and prescriptive tasks. Following this, this article analyzes current research trends and finds a growing shift from knowledge-based models towards data-driven models. Furthermore, this paper discusses the major challenges in this research field, including data processing, data management, and data analytics; the challenges introduced by large language models in power systems; and the limitations related to AI model interpretability and generalization capability. Finally, this article outlines several potential future research directions.

21 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
RSRuihua Si
Ruihua Si
XYXintong Yan
Xintong Yan
WLWanxun Liu
Wanxun Liu
PZPing Zhang
Ping Zhang
梦王梦迪 王
梦迪 王
XSXiangjing Su
Xiangjing Su
The increasing penetration of distributed generation (DG) brings about great economic and environmental benefits, while also negatively affecting the operation of distribution networks due to its high intermittency. Although distributed energy storage (DES) can effectively deal with the problems caused by massive DG penetrations by decoupling the generation and consumption of electricity, the placement of DES significantly determines the effectiveness of its capabilities. Unfortunately, existing DES placement studies are commonly based on a balanced network model, whereas practical distribution networks are unbalanced. In addition, existing DES placement studies are mostly based on an extreme scenario and rarely consider the operational complexity resulting from the uncertainties of DGs and loads. To address the aforementioned challenges, this paper proposes a hierarchical and sequential DES placement strategy in distribution networks by considering multi-scenario operations. Specifically, the proposed hierarchical framework for DES placement includes three sequential layers: outer, inter, and inner. In the outer layer, a multi-scenario comprehensive loss sensitivity index (MSCLSI) is first introduced to search for the most effective DES placement location. Subsequently, the sizing and scheduling of DES for the selected location are conducted through coordinated optimization across the inter and inner layers, which can be solved using a hybrid method combining particle swarm optimization and second-order cone programming (PSO-SOCP). Finally, a series of detailed simulations are carried out over the IEEE-33 test system and the experimental results demonstrate that the proposed scheme can provide significant effectiveness and superiority compared to the state-of-the-art schemes.

23 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
SWShuo Wu
Shuo Wu
JGJunhao Gong
Junhao Gong
SXShiqu Xiao
Shiqu Xiao
Jiajia YangJiajia Yang
Jiajia Yang
XSXiangjing Su
Xiangjing Su
Virtual power plant (VPP) is a critical platform for modern distribution systems with distributed generators (DGs). However, its cybersecurity is susceptible to cyber-attacks such as false data injection attacks (FDIAs). The impacts of FDIAs on VPP-distribution cyber–physical power systems have not been thoroughly investigated in the literature. This study concentrates on the distribution–VPP joint system and designs a new FDIA framework, topology-distributed-generator attack (TDA), that manipulates power network topology and DG outputs. An attack vector is designed carrying incorrect topology, falsified DG outputs, and tampered power flow information that can bypass the existing bad data detection and topology error identification, misleading the decision-making in the control center. Additionally, TDA models are formulated to optimize attack vectors based on objectives of attack investment, VPP economic loss, and operational security. A hybrid solution framework is then proposed for the optimization problem above, where the corresponding submodules realize the bad data detection, topology error identification, and optimal dispatching in the optimal attack vector. The effectiveness and superiority of the proposal are numerically verified on a 62-node cyber–physical system. Key findings highlight that VPP-integrated distribution systems are more vulnerable under low-level renewable energy penetration and the urgent need for enhancing backup power supplies to mitigate such threats.

2 April 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
QCQiuhui Chen
Qiuhui Chen
JGJunhao Gong
Junhao Gong
XSXiangjing Su
Xiangjing Su
FLFengyong Li
Fengyong Li
Typhoon-induced extreme weather poses a severe threat to power systems with high offshore wind penetration. Source-side wind turbine tripping and grid-side transmission line failures are likely to occur simultaneously, which may trigger cascading outages and large-scale load shedding. A multi-level source-grid-load-storage preventive resilience dispatch strategy is proposed. A typhoon spatiotemporal evolution model is first established based on the Batts gradient wind model. Failure probability models for offshore wind turbines and overhead transmission lines are developed while considering strong wind and lightning strike effects. The most probable and severe fault scenario is identified using an entropy-based quantification method. A two-stage robust preventive dispatch model is subsequently formulated. In the day-ahead stage, unit commitment, multi-type reserve allocation, and pumped storage scheduling are optimized at a 1 h resolution. In the real-time stage, combined wind-storage systems are coordinated at a 10 min resolution to accommodate rapid wind power ramps caused by high-wind shutdown events. The model is reformulated through Lagrangian duality and solved by the Benders decomposition algorithm. Case studies on a modified IEEE-RTS 24-bus system with three offshore wind farms demonstrate that the proposed strategy reduces wind curtailment by 66.3%, load shedding by 74.6%, and total cost by 14.8% compared with the case without energy storage. The combined operation cost of storage resources accounts for only 3.1% of the total cost, confirming its favorable cost-effectiveness for resilience enhancement. The proposed strategy contributes to the sustainable integration of offshore wind energy by ensuring a reliable power supply during extreme weather events.