Junhao Gong

Dr. Junhao Gong


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
SWShuo Wu
Shuo Wu
JGJunhao Gong
Junhao Gong
SXShiqu Xiao
Shiqu Xiao
Jiajia YangJiajia Yang
Jiajia Yang
XSXiangjing Su
Xiangjing Su
Virtual power plant (VPP) is a critical platform for modern distribution systems with distributed generators (DGs). However, its cybersecurity is susceptible to cyber-attacks such as false data injection attacks (FDIAs). The impacts of FDIAs on VPP-distribution cyber–physical power systems have not been thoroughly investigated in the literature. This study concentrates on the distribution–VPP joint system and designs a new FDIA framework, topology-distributed-generator attack (TDA), that manipulates power network topology and DG outputs. An attack vector is designed carrying incorrect topology, falsified DG outputs, and tampered power flow information that can bypass the existing bad data detection and topology error identification, misleading the decision-making in the control center. Additionally, TDA models are formulated to optimize attack vectors based on objectives of attack investment, VPP economic loss, and operational security. A hybrid solution framework is then proposed for the optimization problem above, where the corresponding submodules realize the bad data detection, topology error identification, and optimal dispatching in the optimal attack vector. The effectiveness and superiority of the proposal are numerically verified on a 62-node cyber–physical system. Key findings highlight that VPP-integrated distribution systems are more vulnerable under low-level renewable energy penetration and the urgent need for enhancing backup power supplies to mitigate such threats.

2 April 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
QCQiuhui Chen
Qiuhui Chen
JGJunhao Gong
Junhao Gong
XSXiangjing Su
Xiangjing Su
FLFengyong Li
Fengyong Li
Typhoon-induced extreme weather poses a severe threat to power systems with high offshore wind penetration. Source-side wind turbine tripping and grid-side transmission line failures are likely to occur simultaneously, which may trigger cascading outages and large-scale load shedding. A multi-level source-grid-load-storage preventive resilience dispatch strategy is proposed. A typhoon spatiotemporal evolution model is first established based on the Batts gradient wind model. Failure probability models for offshore wind turbines and overhead transmission lines are developed while considering strong wind and lightning strike effects. The most probable and severe fault scenario is identified using an entropy-based quantification method. A two-stage robust preventive dispatch model is subsequently formulated. In the day-ahead stage, unit commitment, multi-type reserve allocation, and pumped storage scheduling are optimized at a 1 h resolution. In the real-time stage, combined wind-storage systems are coordinated at a 10 min resolution to accommodate rapid wind power ramps caused by high-wind shutdown events. The model is reformulated through Lagrangian duality and solved by the Benders decomposition algorithm. Case studies on a modified IEEE-RTS 24-bus system with three offshore wind farms demonstrate that the proposed strategy reduces wind curtailment by 66.3%, load shedding by 74.6%, and total cost by 14.8% compared with the case without energy storage. The combined operation cost of storage resources accounts for only 3.1% of the total cost, confirming its favorable cost-effectiveness for resilience enhancement. The proposed strategy contributes to the sustainable integration of offshore wind energy by ensuring a reliable power supply during extreme weather events.