Virtual power plant (VPP) is a critical platform for modern distribution systems with distributed generators (DGs). However, its cybersecurity is susceptible to cyber-attacks such as false data injection attacks (FDIAs). The impacts of FDIAs on VPP-distribution cyber–physical power systems have not been thoroughly investigated in the literature. This study concentrates on the distribution–VPP joint system and designs a new FDIA framework, topology-distributed-generator attack (TDA), that manipulates power network topology and DG outputs. An attack vector is designed carrying incorrect topology, falsified DG outputs, and tampered power flow information that can bypass the existing bad data detection and topology error identification, misleading the decision-making in the control center. Additionally, TDA models are formulated to optimize attack vectors based on objectives of attack investment, VPP economic loss, and operational security. A hybrid solution framework is then proposed for the optimization problem above, where the corresponding submodules realize the bad data detection, topology error identification, and optimal dispatching in the optimal attack vector. The effectiveness and superiority of the proposal are numerically verified on a 62-node cyber–physical system. Key findings highlight that VPP-integrated distribution systems are more vulnerable under low-level renewable energy penetration and the urgent need for enhancing backup power supplies to mitigate such threats.
1 January 2026 in IET Generation, Transmission & Distribution
The emergence of high‐voltage direct current (HVDC) integrated power systems introduces significant out‐of‐distribution challenges to machine learning–based analysis of cascading failures (CFs). Existing algorithms often suffer from poor interpretability and generalisation in handling diverse CF propagation modes. To address these issues, this paper proposes a novel causal graph attention (CGAT) model that captures critical information from CF events to accurately predict propagation paths and impacts. Specifically, by employing a graph attention mechanism, the model extracts both causal and trivial features as distinctive attention dual subgraphs, which aids in differentiating shortcuts in causal variables and improving prediction accuracy. These subgraphs also provide visual representations that highlight the key elements influencing CF propagation. By incorporating interventions, the CGAT model enhances prediction capabilities across a variety of scenarios that include HVDC control strategies and renewable energy sources. Extensive experiments demonstrate the effectiveness and superiority of the proposed CGAT model, which achieves prediction accuracies of 87.57% for CF chains and 92.89% for power losses on the 30‐bus system. Even on the 2737‐sop system, the accuracies remain at 84.69% and 88.14%, respectively. This model provides a highly efficient online early‐warning tool for preventing large‐scale blackouts in modern power systems.