To meet the requirements of riser safety monitoring in offshore oil fields, a new Fiber Bragg Grating (FBG)-based bundle-structure riser stress monitoring sensor has been developed. In cooperation with many departments, a 49-day marine test in water depths of 1365 m and 1252 m was completed on the “HYSY-981” ocean oil drilling platform. No welding and pasting were used when the sensor was installed on risers. Therefore, the installation is convenient, reliable and harmless to risers. The continuous, reasonable, time-consistent data obtained indicates that the sensor worked normally under water. In all detailed working conditions, the test results show that the sensor can do well in reflecting stresses and bending moments both in and in magnitude. The measured maximum stress is 132.7 MPa, which is below the allowable stress. In drilling and testing conditions, the average riser stress was 86.6 MPa, which is within the range of the China National Offshore Oil Corporation (CNOOC) mechanical simulation results.
The sensitivity of gas and water phases to DAS acoustic frequency bands can be used to interpret the production profile of horizontal wells. DAS typically collects acoustic signals in the kilohertz range, presenting a key challenge in identifying the sensitive frequency bands of the gas and water phases in the production well for accurate interpretation. In this study, a gas–water two-phase flow–acoustic coupling model for a horizontal well is developed by integrating a gas–water separation flow model with a pipeline acoustic model. The model simulates the sound pressure level (SPL) and amplitude variations of acoustic waves under different flow patterns, spatial locations, and gas–water ratio schemes. The results demonstrate that within the same flow pattern, an increase in the gas–water ratio significantly elevates acoustic amplitude and SPL peaks within the 5–50 Hz frequency band. Analysis of oil field DAS data reveals that the amplitude response range for stages with a lower gas–water ratio falls within 5–10 Hz, whereas stages with a higher gas–water ratio exhibit an amplitude response range of 10–50 Hz.
This study employed a full-scale cement sheath quality evaluation apparatus, along with a high-precision distributed fiber optic temperature sensing system, to perform real-time, continuous monitoring of the temperature change throughout the cement hydration process. The results of the cement annulus and cement bond defect monitoring during the hydration process indicated that the distributed fiber optic temperature data enabled centimeter-level resolution in defect identification. Defective regions exhibited significantly reduced temperature fluctuation amplitudes, and an inversion in temperature change at the early hydration stage, detected at the cement–defect boundary, facilitated the early detection of defect locations. The distributed fiber optic system was capable of conducting continuous and comprehensive monitoring of the sequential hydration temperature peaks of cement stages injected into the annulus. The results revealed the interdependence among different cement stages, as well as a phenomenon whereby an elevated annular temperature accelerates the progression of cement hydration. The experimental findings provide a reference for identifying the characteristic signals in distributed fiber optic monitoring of well-cementing operations, thereby establishing a foundation for the optimal and effective use of distributed fiber optics in assessing well-cementing quality.