This paper presents a turbine-based MEMS sensor for spirometry application. The compact sensor dimensions allow integration into smart wearable devices for mobile spirometry without a dedicated hand-held component. The sensor is composed of a turbine with embedded magnets, which is surrounded by two stators with micro coils in a PMMA package. Tangential gas flow actuates the turbine on ball bearings, and results in voltage generation due to electromagnetic induction. The sensor was initially characterized with pressurized nitrogen in the range of breathing flow rates. Sensitivity values up to 0.35 V/lpm were demonstrated. The device was then tested with actual breathing by a healthy subject. Sensor output voltages sampled under varying breath strengths ranged from 0.68 V to 2.94 V, corresponding to breathing flow rates of 3.5 lpm and 22.4 lpm, respectively. The device was also tested for power generation for a potential selfpowered operation. A maximum output power of 67 lW was achieved on a resistive load. Energy storage tests using a 1 mF capacitor showed that normal breathing can raise the capacitor voltage to 0.2 V, while a deep breath resulted in 0.6 V. The difference in capacitor voltage poses a potential alternative method for lung volume measurements. The results presented here demonstrate the potential of this sensor to perform spirometry tests in wearable electronic devices such as smart watches and smart bands.
This paper reports a novel piezoelectric energy harvester incorporated on a waistbelt for power generation from waist movements. The device is composed of multiple piezoelectric disks in 3 D-printed encapsulations and rectifying circuity, which are connected to a battery for energy storage. The harvester was simulated and tested through different body activities. Measured open circuit voltages up to 19 V, μW-level AC power generation, and energy storage test results clearly demonstrate that the energy harvester presented here can effectively convert waist movements into electrical power, store energy in a battery, and support the batteries of wearable electronic devices for extended operations.
25 October 2019 in Journal of Electrical Engineering & Technology
Purpose: The purpose of this study is to develop a non-enzymatic based glucose-sensing platform composed of Bodipy-BBV dual system which can be monitored by a photodetector under the blue LED excitation. Design/methodology/approach: The sensor has been developed from a dual system including a fluorescent dye, an aldehyde derivative of boron dipyrromethene (Bodipy) and a quencher, orto-boronic acid linked viologen (o-BBV) where their combination resulted in a ratiometric fluorescence quenching in ethanol: PBS (1:1, pH:7.4) solution under UV light excitation. By glucose addition, o-BBV has been released from the Bodipy and binded to cis-diol groups of glucose, thereby fluorescence emission of Bodipy has been regained. Furthermore, a setup consisting of a light emitting diode (LED) and a photodiode (PD) was used to prove electrical detection of glucose without the need for expensive and bulky optical equipment, enabling the development of a miniaturized and low-cost glucose-sensing platform. Findings: The fluorescence intensity of the Bodipy derivative in the solution (2 × 10−6 M) was diminished by 93% in the presence of o-BBV solution (5 × 10−3 M). Upon the glucose addition, 81% of the Bodipy fluorescence intensity has been recovered after introduction of 30 mM of glucose, where the ratio of o-BBV/Bodipy was 35:1. A linear response between 10 and 30 mM glucose concentration was obtained, which covers the biologically significant range. A high correlation between the photodiode current and Bodipy fluorescence intensity was achieved. Originality/value: Even though Bodipy molecules are known with their superior optical properties and applied to the fluorescence-based detection of glucose, to the best of the authors’ knowledge, no work has been reported on Bodipy-BBV dual system to detect glucose molecules as a non-enzymatic based method. This design enables the dye and the quencher to independently coexist in the solution, allowing for tuning of their individual concentrations to optimize the glucose sensitivity. Furthermore, an electrical light detection scheme consisting of a LED and a photodiode has been implemented to eliminate the bulky optical equipment from the measurement setup and further this work for the development of a compact and inexpensive sensor. The results presented here demonstrate the feasibility of this system for the development of a novel glucose sensor.
A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibility. Mechanical excitation of this device within the body due to daily activities leads to a relative motion between the platform and stators, resulting in electromagnetic induction. Initial prototypes without packaging have been fabricated and characterized on a linear shaker. Dynamic tests showed that the friction force acting on the platform is on the order of 0.6 mN. The resistance and the inductance of the coils were measured to be 2.2 Ω and 0.4 µH, respectively. A peak open circuit voltage of 1.05 mV was generated per stator at a platform speed of 5.8 cm/s. Further development of this device offers potential for recharging the batteries of implantable biomedical devices within the body.