A non-contact and non-invasive physiological radar monitoring system (PRMS) is introduced. The system is based on motion detection using quadrature microwave Doppler radar, eliminating the need to place sensors on the body. An algorithm was designed to perform real-time actigraphy and sleep apnea detection. The system was validated with clinical polysomnography(PSG) in a sleep study facility on ten consented volunteers with known obstructive sleep apnea. Data obtained from both PRMS and clinical PSG systems were rated by a sleep technician and show an excellent agreement in the detected apnea and hypopnea events. The apnea-hypopnea events were distinguished with an overall sensitivity of 86%, the specificity of 91% and accuracy of 92%.
Cheyne-Stokes respirations occur in 40% of patients with heart failure. Orthopnea is a cardinal symptom of heart failure and may affect the patient's sleeping angle. The objective of this study was to assess the respiratory and hemodynamic response to sleeping angle in a group of subjects with stable heart failure. Twenty-five patients underwent overnight polysomnography with simultaneous and continuous impedance cardiographic monitoring. Sleeping polysomnographic and impedance cardiographic data were recorded. The study was conducted in a sleep center. All 25 patients had clinically stable heart failure and left ventricular ejection fractions < 40%. The patients slept at 0°, 15°, 30°, and 45° in random order. Seventeen patients had Cheyne-Stokes apneas (index > 5/h) and 23 patients had hypopneas (index > 5/h). The hypopnea index showed no response to sleeping angle. The Cheyne-Stokes apnea index decreased with increasing sleeping angle (P < 0.001). This effect was seen only during supine sleep and non-rapid eye movement sleep and was absent in non-supine sleep, rapid eye movement sleep, and during periods of wakefulness. Thoracic fluid content index and left ventricular hemodynamics measured by impedance cardiography showed no response to sleeping angle. Changing the heart failure patient's sleeping angle from 0° to 45° results in a significant decrease in Cheyne-Stokes apneas. This decrease occurs on a constant base of hypopneas. The changes in Cheyne-Stokes apneas are not related to changes in lung congestion and left ventricular hemodynamics.
A design for a physiological radar monitoring system (PRMS) that can be integrated with clinical sleep monitoring systems is presented. The PRMS uses two radar systems at 2.45GHz and 24 GHz to achieve both high sensitivity and high resolution. The system can acquire data, perform digital processing and output appropriate conventional analog outputs with a latency of 130 ms, which can be recorded and displayed by a gold standard sleep monitoring system, along with other standard sensor measurements.