Purpose: The Predicting Myopia Onset and progression (PreMO) risk indicator, developed using data generated from white children in the UK, incorporates age, spherical equivalent refraction (SER), axial length (AL) and parental myopia to stratify the likelihood of developing myopia. This study evaluated the PreMO's predictive accuracy using prospective datasets from independent samples of children in Hong Kong (HK) and an ethnically diverse cohort of children in the United Kingdom. Methods: Non‐myopic children (SER > –0.50 D) aged 6–8 and 9–10 years were scored using the PreMO risk indicator framework, integrating baseline cycloplegic SER, AL and parental myopia data. Scores were assigned risk categories as follows: 0 = no risk, 1–3 = low risk, 4–6 = moderate risk and 7–9 = high risk. SER at ≥15 years of age was used to define refractive outcomes as ‘myopic’ or ‘not myopic’. PreMO's predictive accuracy was analysed via Receiver Operator Characteristic curves, with Youden's J ‐Index identifying the optimal risk score threshold. Sensitivity, specificity and area under the curve were determined and compared with those of singular predictors, that is, SER < +0.75 D and AL ≥ 23.07 mm at 6–8 years. Results: In the cohort of children aged 6–8 years, a PreMO risk score ≥ 4 exhibited high sensitivity in predicting myopia onset in UK (0.97) and HK (0.94) children, with high specificity in UK (0.96) and moderate specificity in HK (0.64) children. In UK children aged 6–8 years, the PreMO outperformed singular predictors such as SER and AL. Among HK children aged 9–10 years, the PreMO score maintained high sensitivity (0.90) and moderate specificity (0.72). Conclusions: A PreMO risk score ≥ 4 is a strong predictive indicator for future myopia onset, particularly in UK children. Despite high sensitivity in both UK and HK cohorts, specificity varied, indicating the need for contextual application of the tool, particularly in pre‐myopic Asian children.
To characterize axial length (AL) growth trajectories in children who developed myopia compared with children who remained nonmyopic. Retrospective longitudinal cohort study. Clinical data from 895 Chinese children (aged 4-15 years at baseline) with nonmyopic refractive error (spherical equivalent refraction> -0.50 D) at baseline spanned at least 2 years. They were categorized into nonmyopic (n = 541) and incident myopia (n = 354) groups, based on whether they developed myopia (SE ≤ -0.50 D) during follow-up. Children in the incident myopia group contributed data to both premyopia onset and postmyopia onset stages. Right eye data were used for all analyses. Participants were classified as myopic based on the right eye's spherical equivalent refraction, regardless of the left eye status. AL was measured at multiple visits, and the rate of AL growth between visits calculated. Generalized estimating equations were used to model AL growth rate, accounting for within-subject correlations. Age, baseline AL, gender, and parental myopia were included as predictors in the model. Annual AL growth rate (mm/y). Generalized estimating equations modeling revealed significant differences in AL growth rates; children in the postmyopia onset stage exhibited significantly faster AL growth compared to both the children in the premyopia onset stage and nonmyopic group (P < .001). This difference was most pronounced in younger children and diminished with age. Postmyopia onset AL growth was significantly faster than premyopia onset growth up to age 7 and the nonmyopic group up to age 10 (P < .05). All groups showed an age-related decline in AL growth rate, with the decline being most pronounced in children in the postmyopia onset stage, followed by the nonmyopic group, and then children in the premyopia onset stage Baseline AL was significantly associated with postmyopia onset AL growth rate (P < .001) but not with premyopia onset (P = .22) or nonmyopic (P = .07) growth rates. Neither gender nor parental myopia significantly impacted AL growth rate. AL growth accelerates significantly after myopia onset, particularly in children younger than 10. This underscores the need for prompt myopia control interventions in early-onset myopia.
28 October 2025 in Ophthalmic and Physiological Optics
Introduction: Myopia is a growing public health concern with long‐term risks for visual impairment. While Defocus Incorporated Multiple Segments (DIMS) spectacle lenses have proven efficacy in Chinese children, evidence from Western populations remains limited. This multi‐site interventional study evaluates the effectiveness of DIMS lenses in slowing myopia progression and their visual acceptability and tolerability among UK children. Methods: Children aged 5–15 years with cycloplegic spherical equivalent refraction (SER) of −0.50 to −8.50 D, anisometropia ≤1.50 D and astigmatism ≤2.50 D were recruited. All participants were prescribed DIMS spectacle lenses. SER (cycloplegic autorefraction) and axial length (AL, IOLMaster) were measured at baseline and at 6‐monthly intervals for 24 months. Measured axial elongation was compared to expected eye growth in age‐ and ethnicity‐matched untreated myopes from published meta‐analyses. Visual function (distance/near visual acuity, stereoacuity, accommodative lag and ocular posture) and visual symptoms (participant questionnaire) were also assessed. Results: A total of 108 participants completed the study to 2 years (baseline age 10.2 ± 2.2 years). Model‐adjusted mean (SE) changes in SER and AL change were −0.35 ± 0.04 D and 0.17 ± 0.01 mm at 12 months and −0.57 ± 0.05 D and 0.30 ± 0.03 mm at 24 months. Compared to expected untreated myopic progression, children wearing DIMS spectacle lenses showed 0.27 ± 0.20 mm (mean ± SD) less axial elongation over 24 months, with 91% exhibiting slower than average untreated myopic eye growth. Measures of visual function were comparable through DIMS and single‐vision spectacle lenses. Fifty‐seven percent of participants reported no visual symptoms within the first week, and on average, visual symptoms were ‘never’ or ‘seldom’ experienced by participants after 12 and 24 months of DIMS wear. Conclusions: This study provides robust and novel evidence demonstrating that DIMS spectacle lenses provide meaningful slowing of axial elongation among UK children. Minimal visual symptoms and preserved visual function throughout lens wear support their clinical viability and real‐world applicability for myopia management in diverse populations.
Purpose. Previous studies have demonstrated an association between melatonin status and both refractive error and axial length in young adult myopes. This study aimed to determine if this relationship extends to a younger adolescent cohort. Methods. Healthy children aged 12–15 years provided morning saliva samples before attending Ulster University (55°N) for cycloplegic autorefraction and axial length measures. Participants completed questionnaires describing recent sleep habits and physical activity. Salivary melatonin was quantified using high‐performance liquid chromatography‐tandem mass spectrometry. Data collection for all participants occurred over a 1‐week period (April 2021). Results. Seventy participants aged 14.3 (95% CI: 14.2—14.5) years were categorised by spherical equivalent refraction [SER] (range: −5.38DS to +1.88DS) into two groups; myopic SER ≤ −0.50DS (n = 22) or nonmyopic −0.50DS < SER ≤ +2.00DS (n = 48). Median morning salivary melatonin levels were 4.52 pg/ml (95% CI: 2.60–6.02) and 4.89 pg/ml (95% CI: 3.18–5.66) for myopic and nonmyopic subjects, respectively, and did not differ significantly between refractive groups (P = 0.91). Melatonin levels were not significantly correlated with SER, axial length, sleep, or activity scores (Spearman’s rank, all P > 0.39). Higher levels of physical activity were associated with higher sleep quality (Spearman’s rank, ρ = −0.28, P = 0.02). Conclusion. The present study found no significant relationship between morning salivary melatonin levels and refractive error or axial length in young adolescents. This contrasts with outcomes from a previous study of adults with comparable methodology, season of data collection, and geographical location. Prospective studies are needed to understand the discrepancies between adult and childhood findings and evaluate whether melatonin levels in childhood are indicative of an increased risk for future onset of myopia and/or faster axial growth trajectories and myopia progression in established myopes. Future work should opt for a comprehensive dim‐light melatonin onset protocol to determine circadian phase.
Background/Objectives: The measurement of axial length (AL) is important to monitor the success of interventions to slow childhood myopia, but traditional biometers are expensive for clinicians to acquire. To address this, Oculus has developed the Myopia Master (MM), which measures auto-refraction (AR), corneal curvature (CC) and AL. This study compared inter-instrument and inter-examiner measures on the MM, IOL Master 700 (Carl Zeiss Meditec, Jena, Germany) and NVisionK-5001 (Shin-Nippon, Tokyo, Japan) in myopic children. Methods: Fifty-six myopic children participated (mean age 11.93 ± 1.93 years). A first examiner obtained the following under cycloplegia: (i) AR using the NVisionK, (ii) AL and CC using the IOL Master 700 and (iii) AR, AL and CC using the MM. The latter measures were repeated by a second examiner to assess inter-examiner agreement of the MM. Mean differences (MD) and 95% limits of agreement (LoA) were calculated. Spherical equivalent refraction (SER) was calculated using AR values. Acceptable LoA for AL, SER and CC were defined as ±0.05 mm, ±0.40 D and ±0.06 mm, respectively. Results: Inter-instrument LoA between the MM and IOL Master 700 for AL and CC were acceptable (MD 0.02 mm; 95%LoA −0.02 to 0.06 mm and MD 0.025 mm, 95% LoA −0.03 to 0.08 mm, respectively). SER measures between the NVisionK-5001 and MM were not acceptable (MD −0.44 D, 95% LoA −0.91 to 0.03 D). SER values were, on average, 0.44 D more negative when using the MM. Inter-examiner measures on the MM were all acceptable (AL MD 0.00 mm; 95% LoA −0.04 to 0.04 mm; SER MD −0.01 D; 95% LoA −0.33 to 0.32 D; CC MD 0.01 mm; 95% LoA −0.03 to 0.05 mm). Conclusions: The MM demonstrated excellent inter-examiner repeatability. Inter-instrument agreement between the MM and IOL Master 700 for the AL and CC measures showed excellent agreement. The MM over-estimated myopia SER compared with the NVisionK-5001.
19 July 2025 in Ophthalmic and Physiological Optics
Introduction: This study evaluated the QuickSee autorefractor for measurement of the accommodative response in a cohort of children without significant ametropia, and compared the findings to those determined using the gold‐standard Shin‐Nippon device. Methods: Children aged 5–7 years were recruited. QuickSee and Shin‐Nippon autorefractors were used to measure refractive status at distance (4 m) and near (50, 33 and 25 cm). Accommodative response was calculated as the difference between distance autorefraction and the value obtained for each accommodative demand. Individual accommodative response slopes were calculated from linear regression for response against demand and averaged to calculate mean slopes for each autorefractor. Inter‐instrument agreement between the QuickSee and Shin‐Nippon was assessed using the Bland–Altman method and 95% limits of agreement. Differences in measured accommodative responses between devices across accommodative demand were assessed by repeated measures ANOVA. Results: Forty‐nine children with a median (IQR) spherical equivalent refraction of +0.38 (0.50 D) (range −0.63 to +1.50 D) participated. Median (IQR) accommodative responses for the 2, 3 and 4 D demands were 1.63 D (0.69), 2.50 D (0.75) and 3.13 D (0.63), respectively, for QuickSee, and 1.63 D (0.69), 2.50 D (0.56) and 3.25 D (0.63) for the Shin‐Nippon. Mean ± SD slopes for accommodative response were 0.75 ± 0.22 and 0.83 ± 0.18 for QuickSee and Shin‐Nippon, respectively ( p = 0.09). Pearson's correlation showed no significant proportional bias for measures of accommodative response with either autorefractor ( p ≥ 0.19). The mean difference in accommodative response measured by the QuickSee and Shin‐Nippon did not differ significantly with accommodative demand ( F = 1.70, p = 0.19). Conclusion: The agreement observed here demonstrates that the QuickSee shows promise in measuring accommodative response over a range of demands (2, 3 and 4 D) in a paediatric population without significant ametropia. Further research is required to determine if these findings translate over a wider range of refractive errors, and to evaluate the value of QuickSee accommodative response measures in vision screening.