Magnetic field shields are important for electronic equipment, ultrahigh-sensitivity sensors, and electrical instruments. For ultrahigh-sensitivity atomic sensors, in particular, ferrite shields with low intrinsic magnetic noise are widely used. In this article, the calculation methods of longitudinal and transverse magnetic noise, which are calculated by loss, are analyzed. The experimental results confirm the feasibility of the model. Using the loss separation method, it is proved that the loss of ferrite magnetic shielding is mainly hysteresis loss, which is below 100 Hz. To effectively reduce the magnetic noise, we analyze the effect of structure parameters on the longitudinal and transverse magnetic noise, and the optimized parameters are obtained. The results show that the longitudinal magnetic noise decreases with the increasing aspect ratio and stabilize eventually. When the aspect ratio exceeds 1, the transverse magnetic noise remains practically unchanged. When the external diameter is fixed, by optimizing the thickness of the magnetic shield, the optimal solution for the longitudinal and transverse magnetic noise is obtained.
The fluctuations of the probe light intensity seriously affect the performance of the sensitive atomic magnetometer. Here we propose a novel method for the intensity stabilization based on the second harmonic component of the photoelastic modulator (PEM) detection in the atomic magnetometer. The method not only could be used to eliminate the intensity fluctuations of the laser source, but also remove the fluctuations from the optical components caused by the environment. A relative fluctuation of the light intensity of 0.035% was achieved and the corresponding fluctuation of the output signal of the atomic magnetometer has decreased about two orders of magnitude from 4.06% to 0.041%. As the scheme proposed here only contains optical devices and does not require additional feedback controlled equipments, it is especially suitable for the integration of the atomic magnetometer.
5 December 2019 in IEEE Photonics Technology Letters
A sapphire fiber high temperature sensor based on Fabry-Perot interference was studied in the paper. A sapphire wafer served as the Fabry-Perot cavity was fixed to the end face of the sapphire fiber. The sensor was encapsulated in an alumina ceramic tube-ceramic sleeve structure to improve structural stability. Experiment results showed the sensor had a wide temperature measurement range of 25 °C-1550 °C. The temperature sensitivity reached 32.5 pm/°C at 1550 °C. Furthermore, the temperature was demodulated from the interference spectrum through fast Fourier transform algorithm. It was concluded that the sapphire fiber sensor with advantages of small size, good stability and a wide range of temperature measurement is very promising for measuring high temperature.
The light shift is an important error source for atomic magnetometers. It would vanish if the frequency of the circularly polarized light is tuned to the optical resonance center. For high-density alkali-metal atomic magnetometers, the vapor cell has a large optical depth near the resonance, resulting in the difficulty in obtaining the exact resonance center by measuring the optical absorption line. In order to solve this problem, we propose a method to tune the pump light to a frequency where the shift is minimum based on the magnetic field zeroing technique. In addition, we also compare our results with the fitting center of the optical absorption line based on the measurement data far detuned from the resonance. The experimental results show that our method achieves a better suppression result of the light shift.
Electrical heating elements, which are widely used to heat the vapor cell of ultrasensitive atomic magnetometers, inevitably produce a magnetic field interference. In this paper, we propose a novel measurement method of the amplitude of electrical-heating-induced magnetic field for an atomic magnetometer. In contrast to conventional methods, this method can be implemented in the atomic magnetometer itself without the need for extra magnetometers. It can distinguish between different sources of magnetic fields sensed by the atomic magnetometer, and measure the three-axis components of the magnetic field generated by the electrical heater and the temperature sensor. The experimental results demonstrate that the measurement uncertainty of the heater’s magnetic field is less than 0.2 nT along the x-axis, 1.0 nT along the y-axis, and 0.4 nT along the z-axis. The measurement uncertainty of the temperature sensor’s magnetic field is less than 0.02 nT along all three axes. This method has the advantage of measuring the in-situ magnetic field, so it is especially suitable for miniaturized and chip-scale atomic magnetometers, where the cell is extremely small and in close proximity to the heater and the temperature sensor.
A stable magnetic field environment is one of the key factors to realize the ultrasensitive magnetic field detection. Ferrite materials, which possess both high electrical resistivity and high permeability, are ideal magnetic shielding materials. Gaps and holes usually exist in the large size magnetic shield which effect shielding effectiveness. In this paper, the variation of the DC magnetic shielding ratio, for different gaps and access hole dimensions, is quantificationally investigated using the finite element method. The shielding ratio in the simulation is close to the theoretical calculation for the closed shield when the thickness of gaps is very small. Our study indicates that gaps and holes separately reduced the shielding effectiveness, and the coexistence of gaps and holes aggravated the reduction of shielding effectiveness. Compared with shielding ratio of the ferrite enclosure without gaps and holes for the known size shield, the transverse and longitudinal direction of the shielding ratio increase by 9% and 274% with gaps (thickness=0.1 mm) and holes (diameter=25 mm), respectively. The simulation results are partially verified with experimentally using cylindrical ferrite shield made of Zn0.17Mn0.74Fe2.06O4 and Zn0.33Mn0.58Fe2.06O4. The difference between the experimental and simulation results is less than 10%.