A low-flow flowmeter based on the bending measurement of a cladding fiber Bragg grating (CLFBG) has been proposed and demonstrated. The CLFBG is fixed in a cantilever beam structure composed of a spring and a circular target. A femtosecond laser side-illumination technique was utilized to ensure that the grating inscription remains close to the core–cladding interface of the multi-cladding fiber (MCLF). The cladding resonance presents fiber bending dependence because of asymmetrical distribution of the CLFBG along the fiber cross-section. The force exerted on the circular target by the slow flow rate of the fluid on the order of mm/s bends the fiber, which changes the peak intensity of the cladding mode. The experimental results show that the sensor responds in the range of 0 - 87 mm/s and has extremely low-temperature cross-sensitivity. The proposed sensor has potential application prospects in high-precision, low-start flow measurement and can be applied to oil pipelines, downhole and other fields.
14 November 2022 in IEEE Transactions on Instrumentation and Measurement
We propose and demonstrate a suspended fiber-optic Fabry–Pérot interferometer for sensitivity-improved high-pressure measurement. A thin-cladding fiber (TCF) is inserted into a silica capillary wherein the end faces of the TCF and single-mode fiber form a suspended FP structure. The sensitivity of the sensor is determined by the air microcavity length L 1 and capillary length L 2 . The sensitivity can be controlled by changing the L 2 / L 1 ratio. A capillary with inner and outer diameters of 100 μm and 150 μm, respectively, was used to experimentally demonstrate this sensitivity enhancement. The L 2 / L 1 ratio was increased from 13.4 to 114.6 and the sensitivity increased from -361.41 pm/MPa to -2975.21 pm/MPa were achieved. In the pressure measurement range of 0–80 MPa, the uncertainty in pressure measurement of the packaged sensor was 0.03%. The sensor has the advantages of small size, simple structure, remarkable accuracy, large range, together with a much suppressed temperature cross-sensitivity, approximately 0.0011 MPa/°C.
We have studied the magnetization, dielectric permittivity, thermal expansion, and magnetostriction of single crystals. Different from that of the plane, the axis magnetization approaches zero at low magnetic fields and a spin-flop transition happens around . The results indicate that the axis is the hard axis and the plane is the easy plane. The high-field isothermal magnetization measured at reveals that the saturation magnetic field is , above which the magnetic structure changes from canted-antiferromagnetic order to ferromagnetic order with the saturation magnetic moment Below antiferromagnetic transition temperature , an unusual negative thermal expansion phenomenon is detected along the axis and it can be interpreted by the magnetic structural variation. Based on the magnetization and the magnetostriction data, the magnetic field–temperature phase diagram of is constructed. The magnetodielectric effect confirms the existence of magnetoelectric coupling in .
25 April 2025 in IEEE Transactions on Instrumentation and Measurement
This study aims to explore the temperature and pressure dual-parameter performance of the all-optical fiber suspended microstructure as well as the relationship between the pressure sensitivity (Sp) and wall thickness (t) of the capillary fiber. This expands on previous research that examines the relationship between the Sp and L2/L1 of the suspended microstructures. The sensor uses a wavelength tracking method, and its wavelength response to pressure changes can reach the Sp of 1495.71 pm/MPa. The temperature and pressure dual parametric performance of this type of sensor at 150 °C and 50 MPa was characterized under laboratory conditions. After one week of continuous high-temperature and high-pressure longterm testing, the maximum difference in Sp fluctuation was 2.28 pm/MPa, which accounted for ±0.25%F.S. of the Sp at the given temperature. Additionally, the pressure point exhibited a fluctuation of 10.07 MPa, accounting for 10.14%F.S. of the entire pressure range. Notably, the sensor continued to exhibit good stability and repeatability throughout the testing process. Analysis of a large amount of test data verified an inversely proportional relationship between the Sp of the sensor and the t of the capillary fiber. Increasing the t of the capillary fiber can improve the overall temperature and pressure resistance of the sensing microstructure; however, Sp will be lost to some extent. The high-temperature and high-pressure sensors are responsive, highly stable, repeatable, accurate, and sensitive for long-term monitoring of high temperatures and pressures.
In this paper, we proposed a Fiber Bragg Grating (FBG) based on identification of bubble collision and bounce. The FBG target sensor detects the vibration signal resulting from the multiple rebound motions of the bubble after colliding with the target. The tension, diameter, and velocity of the bubbles are related to the frequency and amplitude of the vibration signal. In the test of a single target sensor, the frequency of air bubbles is measured to be within the range of 80-100 Hz which is higher than the frequency of oil bubbles within the range of 0-10 Hz. An annular sensing array based on a 3D printed structure is also demonstrated for measuring the cross-sectional bubbles passing through the pipeline. The proposed sensor introduces a new multiphase sensing principle, paving a way for optical fiber holdup sensor development.
In this paper, we propose a double-FBG-based sensor for measuring the holdup of two-phase flow. The sensor consists of a double-FBG and a flexible sheet which has tangential movement in the fluid. The tangential movement can be measured by FBG wavelength shift. The test results show that the flow rate, holdup and temperature are related to the FBG wavelength shift. This means that the holdup can be calculated by the FBG wavelength signal when the flow rate and temperature are known. A double-FBG uses differential amplification to enhance sensitivity and eliminate self-temperature effect. The flexible sheet,with a thickness of 0.1 mm and a size of 10 mm×20 mm, reduces the normal force and increases the tangential force. The sensor was verified to measure the holdup of different holdup of oil-water mixtures in the pipeline, with an error of 6.69%- 12.67%. The measurements introduce a novel principle for two-phase flow sensing, proposing possibilities for the advancement of optical fiber holdup sensors.