Magnetic field shields are important for electronic equipment, ultrahigh-sensitivity sensors, and electrical instruments. For ultrahigh-sensitivity atomic sensors, in particular, ferrite shields with low intrinsic magnetic noise are widely used. In this article, the calculation methods of longitudinal and transverse magnetic noise, which are calculated by loss, are analyzed. The experimental results confirm the feasibility of the model. Using the loss separation method, it is proved that the loss of ferrite magnetic shielding is mainly hysteresis loss, which is below 100 Hz. To effectively reduce the magnetic noise, we analyze the effect of structure parameters on the longitudinal and transverse magnetic noise, and the optimized parameters are obtained. The results show that the longitudinal magnetic noise decreases with the increasing aspect ratio and stabilize eventually. When the aspect ratio exceeds 1, the transverse magnetic noise remains practically unchanged. When the external diameter is fixed, by optimizing the thickness of the magnetic shield, the optimal solution for the longitudinal and transverse magnetic noise is obtained.
7 June 2022 in IEEE Transactions on Industrial Electronics
Square coils with a high magnetic field uniformity have a wide range of applications. This article innovatively proposes a hybrid design optimization method for uniform magnetic field coils. The Taylor series expansions of the three components (3-TE) are applied to the design of multiple pairs of square coils for the first time, and on this basis, field relative errors of the target field points are further combined to improve the uniformity of the target area. Through this hybrid optimization method, the design of the coils is transformed into a constrained nonlinear optimization problem, and the structural parameters are obtained through the particle swarm optimization algorithm. Simulation and experimental results establish that in comparison with the conventional square Helmholtz coil, the uniformity of the coils designed by the 3-TE method has been optimized by 52.83%, and the introduction of target field points further improved the uniformity by 86.61% in the target area. Simultaneously, the proportion of areas with a field relative error of less than 10 −4 increased from 5.71 to 21.43% as a consequence of this method.
Functional imaging equipment based on miniaturized atomic magnetometers with array arrangement exhibits promising prospects in biomagnetic scenarios. However, crosstalk from the modulated magnetic field between adjacent sensors degrades the imaging accuracy. To address this issue, this study proposes an all-optical dual-axis zero-field atomic magnetometer using light-shift modulation. We utilize an acousto-optic modulator to modulate a detuned circularly polarized beam for pumping the atomic spin ensembles. This beam allows for the optical modulation of spin polarization and meanwhile generates a light-shift modulation, effectively replacing the conventional magnetic field modulation. By using a probe beam to detect the optical rotation angle perpendicular to the direction of the pump beam, we construct an all-optical configuration of a longitudinally modulated atomic magnetometer, enabling dual-axis magnetic field measurements. Experimental results demonstrate dual-axis sensitivities of 29 and , respectively. This method eliminates the need for conventional coil-based magnetic field modulation, thereby paving the way for potential applications in magnetocardiography and magnetoencephalography.
11 April 2019 in IEEE Transactions on Instrumentation and Measurement
A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.
9 November 2020 in Measurement Science and Technology
In optically pumped alkali vapor cell with high density of atoms, the attenuation of the pump light generates a spatially non-uniform distribution of the electronic spin polarization of alkali atoms, which is detrimental to biomagnetism applications of magnetometers as well as the hyperpolarization of noble gas atoms. Therefore, in this study, we propose a new scheme to generate a nearly uniform, unsaturated spin polarization region based on counter-propagating pump beams and atomic diffusion. A finite element method (FEM)-based simulation is used to demonstrate the three-dimensional distribution of the spin polarization in a spherical cell. The effects of cell temperature and pump light power on the homogeneity of the spin polarization are studied. The distribution of spin polarization near the center of the cell is experimentally measured and a 1-cm uniform spin polarization region is achieved in the center of the cell. The uniformity of spin polarization in the center region of the cell increased by 50% compared with single beam pumping. The advantage of our proposed scheme is that it can generate an unsaturated uniform region of spin polarization in the center of a cell using a single species of alkali atoms.
The light shift is an important error source for atomic magnetometers. It would vanish if the frequency of the circularly polarized light is tuned to the optical resonance center. For high-density alkali-metal atomic magnetometers, the vapor cell has a large optical depth near the resonance, resulting in the difficulty in obtaining the exact resonance center by measuring the optical absorption line. In order to solve this problem, we propose a method to tune the pump light to a frequency where the shift is minimum based on the magnetic field zeroing technique. In addition, we also compare our results with the fitting center of the optical absorption line based on the measurement data far detuned from the resonance. The experimental results show that our method achieves a better suppression result of the light shift.