Andrej Kryžanowski

Dr. Andrej Kryžanowski


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YGYaser Ghafoori
Yaser Ghafoori
AVAndrej Vidmar
Andrej Vidmar
Jaromir RihaJaromir Riha
Jaromir Riha
AKAndrej Kryžanowski
Andrej Kryžanowski
Seepage flow through embankment dams and their sub-base is a crucial safety concern that can initiate internal erosion of the structure. The thermometric method of seepage monitoring employs the study of heat transfer characteristics in the soils, as the temperature distribution in earth-filled structures can be influenced by the presence of seepage. Thus, continuous temperature measurements can allow detection of seepage flows. With the recent advances in optical fiber temperature sensor technology, accurate and fast temperature measurements, with relatively high spatial resolution, have been made possible using optical fiber distributed temperature sensors (DTSs). As with any sensor system, to obtain a precise temperature, the DTS measurements need to be calibrated. DTS systems automatically calibrate the measurements using an internal thermometer and reference section. Additionally, manual calibration techniques have been developed which are discussed in this paper. The temperature data do not provide any direct information about the seepage, and this requires further processing and analysis. Several methods have been developed to interpret the temperature data for the localization of the seepage and in some cases to estimate the seepage quantity. An efficient DTS application in seepage monitoring strongly depends on the following factors: installation approach, calibration technique, along with temperature data interpretation and post-processing. This paper reviews the different techniques for calibration of DTS measurements as well as the methods of interpretation of the temperature data.

3 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MKMateja Klun
Mateja Klun
DZDejan Zupan
Dejan Zupan
JLJože Lopatič
Jože Lopatič
AKAndrej Kryžanowski
Andrej Kryžanowski
This paper presents the first application of the Laser Doppler Vibrometer (LDV) in non-stationary conditions within a hydropower plant powerhouse. The aim of this research is to develop a methodology to include non-contact vibration monitoring as part of structural health monitoring of concrete dams. We have performed in-situ structural vibration measurements on the run-of-the-river Brežice dam in Slovenia during the start-up tests and regular operation. In recent decades, the rapid development of laser measurement technology has provided powerful methods for a variety of measuring tasks. Despite these recent developments, the use of lasers for measuring has been limited to sites provided with stationary conditions. This paper explains the elimination of pseudo-vibration and measurement noise inherent in the non-stationary conditions of the site. Upon removal of the noise, fatigue of the different structural elements of the powerhouse could be identified if significant changes over time are observed in the eigenfrequencies. The use of laser technology is to complement the regular monitoring activities on large dams, since observation and analysis of integrity parameters provide indispensable information for decision making and maintaining good structural health of ageing dams.

29 January 2020 in Water
Verified
Journal Article
Open access
PDF file
YGYaser Ghafoori
Yaser Ghafoori
MMMatej Maček
Matej Maček
AVAndrej Vidmar
Andrej Vidmar
Jaromir RihaJaromir Riha
Jaromir Riha
AKAndrej Kryžanowski
Andrej Kryžanowski
Seepage is the key factor in the safety of dikes and earth-fill dams. It is crucial to identify and localize the seepage excesses at the early stages before it initiates the internal erosion process in the structure. A proper seepage monitoring system should ensure a continuous and wide area seepage measurement. Here, continuous monitoring of seepage at the laboratory-scale is achieved by a passive optical fiber Distributed Temperature Sensing (DTS) system. An experimental model was designed which consists of initially unsaturated sand model, water supply, seepage outflow, optical fiber DTS system, and water and air temperature measurement. Initially, the sand temperature was higher than the temperature of the seepage water. An optical fiber DTS system was employed with a high-temperature resolution, short sampling intervals and short time intervals for temperature monitoring in the sand model. In the system, the small variation in the temperature due to groundwater flow was detected. The numerical analysis was conducted for both the seepage process and the heat transfer progression in the sand model. The results of the heat flow simulation were evaluated and compared with the measured temperature by the optical fiber DTS. Obvious temperature reduction was obtained due to seepage propagation in the sand. The rate of temperature reduction was observed to be dependent on the seepage flow velocity.

4 January 2015
Verified
Book Chapter
Closed access
PDF file
JSJošt Sodnik
Jošt Sodnik
MMManica Martinčič
Manica Martinčič
Matjaž MikošMatjaž Mikoš
Matjaž Mikoš
AKAndrej Kryžanowski
Andrej Kryžanowski

20 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YGYaser Ghafoori
Yaser Ghafoori
AVAndrej Vidmar
Andrej Vidmar
AKAndrej Kryžanowski
Andrej Kryžanowski
Temperature measurements are widely used in structural health monitoring. Optical fiber distributed temperature sensors (DTS) are developed, based on Raman spectroscopy, to measure temperature with relatively high accuracy and short temporal and spatial resolutions. DTS systems provide an extensive number of temperature measurements along the entire length of an optical fiber that can be extended to tens of kilometers. The efficiency of the temperature measurement strongly depends on the calibration of the DTS data. Although DTS systems internally calibrate the data, manual calibration techniques were developed to achieve more accurate results. Manual calibration employs reference sections or points with known temperatures and the DTS scattering data to estimate the calibration parameters and calculate temperature along the optical fiber. In some applications, manual calibration is subjected to some shortages, based on the proposed fiber installation configuration and continuity of calibration. In this article, the manual calibration approach was developed using the model-independent Parameters Estimation (PEST), together with the external temperature sensors as references for the DTS system. The proposed method improved manual calibration in terms of installation configuration, continuity of dynamic calibration, and estimation of the calibration parameters.

31 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AVAndrej Vidmar
Andrej Vidmar
MBMitja Brilly
Mitja Brilly
KLKlaudija Lebar
Klaudija Lebar
AKAndrej Kryžanowski
Andrej Kryžanowski
Various models were developed in the past to simulate different hydrological processes. However, discrepancies between simulated and observed values are still significant and pose a challenge to many researchers. Models contain many parameters that cannot be directly measured. The values of most of these parameters are determined in the calibration process conditioning the efficiency of such models. This paper introduces the use of the enhanced Gauss–Levenberg–Marquardt (GLM) procedure in combination with the singular value decomposition (SVD) and Tikhonov regularization to improve the process of hydrological model calibration. The procedure is tested on a freely available hydrological model using a synthetic dataset. Based on several efficiency measures, the GLM procedure, in combination with SVD and Tikhonov regularization, was found to provide efficient model history matching and almost perfect parameter calibration. Moreover, by comparing the results of the proposed procedure with the results of global evolutionary calibration procedures, it was found that the only calibration using the combined GLM procedure gave a perfect fit in low flows. Last but not least, the noise in the calculation results with the combined GLM method was practically the same in either the calibration or validation procedure, suggesting that only computational noise remained in the results.